For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30-8.20 — General requirements and procedures

Code of Ordinances, City of Gainesville, Florida (Supp. No. 64, Update 1: codified through Ordinance No. 2024-740, adopted November 6, 2025) · Gainesville City Code § 30-8.20

Corpus is an independent public-information project, not the official City of Gainesville website. Stable reference: corpuslaw.us/code/aef98876-00d9-4a1a-aabd-ea6add63d408

Sec. 30-8.20. - General requirements and procedures.

A. Wetlands and required wetland buffers shall not be included within any platted lots or blocks of any subdivision (not including lot splits and minor subdivisions) that is approved after April 12, 2004. B. Except as otherwise provided, there shall be no development in, on or over a surface water or wetland, or within 75 feet of the landward extent of a regulated lake, or within 35 feet of the break in slope at the top of the bank of any regulated creek. C. A minimum buffer distance of 35 feet and an average minimum buffer distance of 50 feet shall be required between the developed area and the landward extent of any wetland or surface water, other than (as provided in the preceding paragraph) a regulated lake or creek. Figure 1 depicts the minimum 50-foot buffer distance without encroachment. Wherever the buffer distance is less than 50 feet, the amount of such encroachment along the 50-foot buffer line shall be mitigated along an equal length of buffer line contiguous to the encroachment. Such mitigation shall consist of increasing the minimum buffer distance so that the average minimum buffer distance of 50 feet is maintained at that location. Figures 2 and 3 depict encroachment of the 50-foot distance with required mitigation contiguous to the encroachment. The required increase in minimum buffer distance can be provided along an equal length of buffer line not contiguous to the encroachment only if greater protection of wetland resources can be attained, subject to the approval of the city manager or designee or appropriate reviewing board. See Figure 4 for depiction of increased minimum buffer distance along equal length of buffer line not contiguous to the encroachment. D. The average minimum distance of 50 feet shall be maintained under all circumstances unless it is established, prior to permitting, by competent, substantial evidence that a distance greater than 50 feet is required for the protection of wetland functions, as required by this article. Buffers shall remain in an undisturbed condition except for drainage features that will not adversely affect wetland functions and public infrastructure exempted by section 30-8.18. Outfall structures from stormwater retention or detention basins can be allowed within required buffers. The buffer shall not apply to surface waters or wetlands created by humans, except those wetlands that are created for mitigation. The buffer shall be clearly delineated with permanent markers. E. Within required wetland or surface water buffers, there shall be no placement of impervious surfaces or sod, except as otherwise allowed pursuant to this article. All invasive, non-native plant species listed in section 30-8.3 shall be removed prior to issuance of the certificate of occupancy. All plants listed on the Noxious Weed List, Section 5B-57.007, Florida Administrative Code, shall be removed prior to issuance of the certificate of occupancy. Native vegetation shall be retained and/or installed in order to protect wetland and surface water environmental features. Figure IX-1. Minimum 50-foot buffer [image omitted; see the official code] Figure IX-2. Buffer encroachment with contiguous increase [image omitted; see the official code] Figure IX-3. Buffer encroachment with contiguous increases [image omitted; see the official code] Figure IX-4. Buffer encroachment with non-contiguous increase [image omitted; see the official code] F. Outstanding Florida Waters, as listed in Section 62-302.700, Florida Administrative Code, shall have a minimum buffer of 200 feet. G. For development activity between 35 and 150 feet from the break in slope at the top of the bank of any regulated creek, it is a rebuttable presumption that the development activity is detrimental to the regulated creek and is therefore prohibited unless approval is granted as set forth below. H. Development plans for lots within 150 feet of any regulated creek shall demonstrate compliance with the following standards (standards (2) and (3) shall not be applied to residential single-family lots): 1. The development will not introduce erosion and sediment pollution to the creek both during and after construction; 2. The first one inch of runoff or appropriate water management district standards, whichever is greater, will either be retained or detained through filtration on the project site; 3. There will be no net increase in the rate of runoff from the site; 4. There is no threat to the stability of the creek bank; and 5. There will be no placement of buildings, structures, impervious surfaces, or sod that would require the removal of vegetation integral to the creek's ecological value. All invasive, non-native plant species listed in section 30-8.3 shall be removed prior to issuance of the certificate of occupancy. All plants listed on the Noxious Weed List, Section 5B-57.007, Florida Administrative Code shall be removed prior to issuance of the certificate of occupancy. Native vegetation shall be installed and/or retained to protect surface water or wetland environmental features. I. The development will not modify groundwater levels so as to have an adverse impact on the hydrological regime of a surface water or wetland. For the purposes of this provision, adverse impact is defined as a change that prevents the surface water or wetland from maintaining a structure and function equivalent to pre-development levels. J. If a proposed development requires development plan review pursuant to article III, the showing of compliance with the requirements of the surface waters and wetlands sections of article VIII shall be made in development plan review. The petition for development plan review shall provide both a hydrological report and construction plans prepared by a qualified engineer registered in the state. K. If a proposed development does not require development plan review, a showing of compliance shall be certified by the city manager's designee prior to issuance of any building permit. To demonstrate compliance with the requirements concerning quality and control of erosion and sediment pollution, the development plan may employ the city's "General Criteria for Controlling Erosion and Sediment," in the design manual, or equivalent practices, rather than employing the more elaborate hydrological and soil reports used in development plan review. Compliance with the measures required by "General Criteria for Controlling Erosion and Sediment" shall be presumed sufficient to meet the standards in subsections 30-8.20.H.1., 2. and 3. The development plan shall provide enough information to demonstrate compliance with the remaining standards, but need not ordinarily be prepared by a registered engineer. A professional land surveyor certified by the state shall provide the lot boundaries survey and topographical information. L. On-site transfer of development intensity and density. In order to protect surface water features of a site, development intensity and density for building areas may be transferred from a lower to a higher elevation within the same property or adjacent property under the same ownership and zoning category. Intensity and density may be apportioned over the property by reserving the surface water and its buffer area as common open space. If all of the intensity and density is transferred to the adjacent property, the owner shall record a restriction in the chain of title of the transferor property, prior to issuance of a final development order, to restrict the use of the land in perpetuity to non-development uses, with such restrictions being expressly enforceable by the city. M. The installation of new septic tanks is prohibited within 150 feet of the landward extent of a regulated lake or wetland, or within 150 feet from the break in slope at the top of the bank of a regulated creek.

Ask a question about Gainesville law

Corpus searches the Gainesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.