For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30-8.3 — Elements of compliance

Code of Ordinances, City of Gainesville, Florida (Supp. No. 64, Update 1: codified through Ordinance No. 2024-740, adopted November 6, 2025) · Gainesville City Code § 30-8.3

Corpus is an independent public-information project, not the official City of Gainesville website. Stable reference: corpuslaw.us/code/cebc34e2-3dc0-4c84-bce5-079156492f85

Sec. 30-8.3. - Elements of compliance.

All property within the city shall be subject to the following regulations, except as exempted by subsection B. below. No parcel within the city may be cleared, grubbed, filled or excavated, nor shall any building be demolished, altered or reconstructed in a manner that negatively impacts regulated trees, changes the site plan, site use or increases the impervious surface area except in compliance with this article. Requirements of these sections do not exempt property owners from compliance with any other section of this chapter. A. Minimum requirements for landscaped areas. All areas designed to meet the requirements of these sections shall comply with the following: 1. Street trees shall be provided a minimum rootzone volume of 700 cubic feet, except street trees that share a rootzone volume shall require a minimum of 550 cubic feet. All other required shade trees shall be provided a minimum of 420 cubic feet of rootzone volume. Where existing conditions preclude the provision of the minimum rootzone volume, the reviewing board or city manager or designee may approve a lesser volume that meets the arboriculture needs of the tree within the existing conditions. Underground utility lines shall not be located within the rootzone volume, except for those lines that are four-inch diameter or less, and then only where the utility separation requirements in subsection 2. below are met. Prior to planting, any limerock or construction debris found in this area shall be removed, and rootzone media soil shall be provided to a depth of at least three feet. Shade trees shall be located a minimum of ten feet from a building face or from major architectural features of the building (including but not limited to balconies, awnings, bay windows or porches). 2. A minimum separation requirement of seven and one-half feet is required between new trees and existing or proposed water, wastewater force main, reclaimed water, gas, electric and telecommunications main and service utility lines, to protect against root incursion. A minimum separation requirement of ten feet is required between new trees and existing or proposed wastewater gravity collection mains and laterals. Where feasible, separations should be marginally increased in order to account for inaccuracies in surveying, engineering or construction. Reduced separation distances to three and one-half feet may be allowed at the discretion of the utility company. In these instances the utility company may require one of the following measures to protect the utility lines, in accordance with the standards established by the utility company: a. Compaction of the soil immediately adjacent to the underground lines to 98 percent proctor density from the utility line to within 12 inches of ground surface; b. Encasing the utility line with excavatable flowable fill, steel casing, or other acceptable methods; c. Wrapping the utility line with an herbicide-impregnated geo-textile bio-barrier cloth; d. Protecting the utility line with structural barriers of cast-in-place or pre-cast concrete panels, steel or high-density plastic sheet-pile barriers; or e. Steel casing, installed in accordance with standards established by the utility company. Where an existing tree is to be preserved, trenchless installation shall be required for the installation of underground utilities, using directional boring or jacking-and-boring of a casing pipe throughout the tree root plate. 3. An irrigation system, or a readily available water supply within a distance of 100 feet, shall be supplied for all landscaped areas. An automatic irrigation system shall be provided for development if the total area of impervious surfaces devoted to vehicular use areas exceeds 10,000 square feet. Such irrigation shall promote water conservation by such methods as drip irrigation and/or efficient sprinkler zoning, as well as reducing the amount of irrigation as plants become established. Each required tree shall be served by a drip ring or bubblers or other appropriate means necessary to ensure that the entire rootball is irrigated. The irrigation system shall be designed and located to minimize the watering of impervious surfaces. Successful establishment of trees should occur within one year. After that time, use of the automatic irrigation system may be discontinued. If the required trees die within three years of planting, they shall be replaced in accordance with this article, and replanted trees will require irrigation throughout the next establishment phase. 4. Landscape areas that are not planted shall be grassed or mulched with organic materials. Grassed areas shall be planted with sod that has been certified free of noxious weeds by the Florida Department of Agriculture and Consumer Services, Division of Plant Industry. 5. When a landscaped area is adjacent to or within a vehicular use area, curbing shall be used to protect landscaped areas from encroachment. Parking spaces shall be designed to provide pervious surface for the vehicle overhang area. Shrubs and trees shall be placed away from the wheel stop, so that they will not be encroached upon by vehicles. In lieu of curbing, the alternative means of preventing encroachment shall be shown on the site plan. 6. All required trees shall be selected from the Gainesville tree list. Tree species not appearing on the Gainesville tree list may be planted only with prior approval of the city manager or designee or appropriate reviewing board. Developments which require 16 or more shade trees shall have at least four different high quality shade tree genera. Street tree diversity is to be attained city-wide in order to reduce the effect of loss of street tree species due to insect or disease outbreaks, even though street tree diversity may not be attained on an individual street. The applicant or landscape contractor shall schedule an on-site meeting with the city manager or designee prior to the installation of any trees or shrubs to ensure compatibility with infrastructure and compliance with landscape code requirements. 7. Any landscaped area adjacent to an intersection or driveway shall conform to the requirements for the vision triangle contained in the City of Gainesville Engineering Design and Construction Manual. 8. Trees located near the street shall be planted in locations that meet the clear zone requirements of the city public works department or the maintaining agency. B. Exemptions to landscaping requirements. 1. Lots designed or designated for single-family residential dwellings and the developed portion of any lot over two acres in actual single-family residential use are exempt from the requirements of this section, except as provided in section 30-8.7. 2. Development within the approach and Airport Runway Protection Zone areas as specified on the adopted Gainesville Regional Airport master plan, on file with the director of aviation, Gainesville Regional Airport, is exempt from the provision of required shade trees in areas where federal regulations prohibit shade trees or where shade tree growth can be expected to penetrate airport zone surfaces regulated under Federal Aviation Regulations 14 CFR, Part 77. If permitted, understory trees must be substituted. Trees may be removed from such areas upon filing a tree removal permit accompanied by submission of written authorization from the Gainesville/Alachua County Regional Airport Authority or FDOT to the City Manager's designee. Reforestation is not required in areas where federal regulations prohibit trees or where shade tree growth can be expected to penetrate airport zone surfaces regulated under Federal Aviation Regulations 14 CFR, Part 77. Mitigation will not be required except for high-quality heritage trees, which must be mitigated in accordance with section 30-8.7. 3. Where required shade trees are expected to conflict with planned solar energy generation, developments may compensate for the required trees by relocating them to a designated area or preserving an equal number of existing high-quality shade trees elsewhere on the site. At least 140 square feet must be provided for each new shade tree to be planted, and existing trees must be preserved in accordance with section 30-8.8. These trees must be located so that they can grow to maturity without obstructing the generation of solar energy, and the area where they are planted or preserved must be delineated and noted as a "designated tree area" on the development plans. C. Expansions, 50,000 square feet or more. Expansions of existing developments that contain 50,000 square feet or more shall comply with the following regulations: Proposed Development | Mandatory Compliance 1. Any expansion which increases the gross floor area of a development by 10% or less. | The expansion area, all areas adjacent to the public right-of-way, as practicable, and all parking spaces directly related to the expansion area. 2. Any expansion which increases the gross floor area of a development by more than 10% but less than 20%. | The expansion area, all areas adjacent to the public right-of-way, and all property within 25 feet, where practicable, plus 25% of the remainder of the development. Removal of asphalt to create street buffers and parking lot islands will be considered practicable. 3. Any expansion which increases the gross floor area of a development by 20% or more but less than 35%. | The expansion area, all areas adjacent to the public right-of-way, and all property within 25 feet, where practicable, plus 50% of the remainder of the development. Removal of asphalt to create street buffers and parking lot islands will be considered practicable. 4. Expansion which increases the gross floor area of a development by 35% or more. | The entire development. 5. For purposes of this subsection, repeated expansions of property, including the construction or erection of separate buildings or accessory structures, which meet the threshold in the table shall comply with the provisions of this article as provided above. 6. The determination of the exact location of the remainder area which shall be brought into landscape compliance shall be made by the appropriate reviewing board. In determining the exact location of such remainder area, the following factors shall be considered: a. Buffering incompatible land uses; b. Improvement to areas of visual or environmental impact; c. The economic and technical feasibility of landscaping particular areas; and d. The visibility of landscaping areas from public roads or sidewalks. D. Expansions, less than 50,000 square feet. Expansions of existing developments that contain less than 50,000 square feet shall comply with the following regulations: 1. Expansions of vehicular use area shall meet the requirements of section 30-8.4 for the expanded area and shall also meet requirements for street and use buffers adjacent to the expanded area. 2. Whenever expansion of a developed area, independently or cumulatively, totals 4,000 square feet or more than 35 percent of the gross square footage of the developed area, whichever is less, the entire site shall be brought into compliance with this article. For the purposes of this subsection, repeated expansions or alterations of the property, including the construction or erection of separate buildings or accessory structures, constructed within a period of 36 months, which meet the above threshold, shall comply with the provisions of this article. 3. Any new use of property which alters the use of existing structures from a residential use to a nonresidential use shall be required to meet all applicable landscaping requirements. The city manager or designee shall determine the applicable requirements based on the character and orientation of the proposed mixed use development. 4. The use of property, including outdoor activities and parking, which expands the lot area of any use, when such property adjoins property in actual use as a single-family residence or shown in any single-family zoning district, shall be required to conform with all buffer requirements. 5. Expansions of outdoor storage shall require screening in accordance with the requirements in section 30-5.19. E. Minimum submittal criteria. All landscape plans shall be drawn to scale and have a north arrow, and accurately depict all buildings, pavement, on-site facilities, utilities and lighting systems. The landscape drawing or accompanying development plan shall give the permitted use of adjacent parcels and the total square footage of all pavement on-site. Stormwater basins shall be designated as either wet or dry. A plant schedule shall be provided showing the botanical name, size, spacing and number of all required plant materials. Architectural symbols depicting trees to be installed shall not exceed the scale equivalent of five feet in diameter with a solid line; a hatched line around the solid line shall show the expected canopy dimension after 20 years as identified in the Gainesville tree list. Any native tree or shrub may be substituted for the identified plant with city staff approval, provided that the tree or shrub is adaptable to the amount of sun/shade, wet/dry and size conditions where it will be planted, and insofar as the provisions for diversity, shading and/or screening described in the article are met. Changing tree species shall not diminish the total number of high quality shade trees in their required locations. Plant material shown in addition to the required elements of the landscape plan may be labeled as optional and shall not be subject to inspection. F. Design principles and standards. All landscaped areas required by this article shall conform to the following general guidelines: 1. The preservation of structurally sound native trees of high quality shade tree species and shrubs is strongly encouraged to maintain healthy, varied and energy-efficient vegetation throughout the city, and to maintain habitat for native wildlife species. Developments should be designed to preserve existing high quality heritage trees, especially those located within 20 feet of the public right-of-way. 2. The landscaping plan should integrate the elements of the proposed development with existing topography, hydrology and soils in order to prevent adverse impacts such as sedimentation of surface waters, erosion and dust. 3. The functional elements of the development plan, particularly the drainage systems and internal circulation systems for vehicles and pedestrians, should be integrated into the landscape plan. The landscaped areas should be integrated, especially to promote the continuity of on-site and off-site open space and greenway systems, and to enhance environmental features, particularly those features regulated by the environmental overlay districts (article VIII). 4. The selection and placement of landscaping materials should maximize the conservation of energy through shading of buildings, streets, pedestrian ways, bikeways and parking areas. Where possible, shade trees should be planted along internal sidewalks that connect buildings to the street sidewalk and to other buildings on the site. 5. Landscaping design should consider the aesthetic and functional aspects of vegetation, both when initially installed and when the vegetation has reached maturity. Newly installed plants should be placed at intervals appropriate to their expected function as short-term or long-term elements. The natural and visual environment should be enhanced through the use of materials which achieve a variety with respect to seasonal changes, species of living material selected, textures, colors and size at maturity. 6. The placement of trees around buildings should permit access to the building by emergency vehicles. 7. The installation of the following invasive nonnative species is prohibited, as is installation of any species labeled as "Prohibited" in the most recently published version of the Institute of Food and Agricultural Science (IFAS) Invasive Species Assessment: INVASIVE, NONNATIVE PLANT SPECIES Common Name | Scientific Name Air potato | Dioscorea bulbifera Arrow bamboo | Pseudosasa japonica Brazilian pepper | Schinus terebenthifolius Catclaw vine | Macfadyena unguis- cati Chinaberry | Melia azedarach Chinese privet | Ligustrum sinense Chinese tallow tree | Sapium sebiferum Chinese wisteria | Wisteria sinensis Climbing fern | Lygodium japonicum and Lvgodium microphyllum Cogon grass | Imperata cylindrica Coral berry | Ardisia crenata Coral ardesia | Ardisia iaponica Elephant's ears | Xanthosoma sagittifolium Glossy privet | Ligustrum lucidum Golden raintree | Koelreuteria paniculata and Koelreuteria bipinnata Golden bamboo | Phvllostachys aurea Henon bamboo | P. nigra cv. "Henon" Hydrilla | Hydrilla verticulata Hygrophia | Hygrophia polysperma Japanese ardisia | Ardisia iaponica Japanese honeysuckle | Lonicera japonica Japanese paper mulberry | Brousonettia papyrifera Kudzu | Pueraria lobata Mimosa | Albizia julibrissin Miramar weed | Hvgrophila polysperma Oyster plant | Tradescantia spathacea Palm leaf bamboo | Sasa palmate (Arundinaria palmata) Skunk vine | Paederia foetida Tropical soda apple | Solanum viarum Wandering spiderwort Water hyacinth | Eichornia crassipes White-flowered small-leaved spiderwort | Tradescantia fluminensis Wild taro | Colocasia esculenta 8. For all new development, or redevelopment of existing property, the applicant shall remove invasive nonnative plant species listed on the Florida Prohibited Aquatic Plants List or the Florida Noxious Weed List from the property in accordance with the management plan prior to issuance of the certificate of occupancy. On property with invasive nonnative plant species, a plan shall be submitted with the development application that includes a timeline, success criteria, treatment recommendations, and identifies methods that will have minimal impact on non-target species. All herbicide applications to control invasive, nonnative plants in wetland or upland set-aside areas (including buffers) shall be applied by a contractor licensed by the Florida Department of Agriculture and Consumer Services, Division of Agricultural Environmental Services, with a current certification in Natural Areas Weed Management. The city manager or designee should inspect such sites for a minimum of three years after completion to verify effectiveness of control efforts. The plan shall state the entity responsible for additional treatments during the three-year follow-up if the populations of invasive nonnative plants rebound and cover more than ten percent of any previously infested area within the wetland or upland set-aside areas. 9. Loblolly and slash pines should be at least 25 feet apart post-development to reduce southern pine beetle infestation outbreaks.

(Ord. No. 170974, § 14, 2-21-19)

Ask a question about Gainesville law

Corpus searches the Gainesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.