§ 30-8.8 — Tree preservation during development and construction
Code of Ordinances, City of Gainesville, Florida (Supp. No. 64, Update 1: codified through Ordinance No. 2024-740, adopted November 6, 2025) · Gainesville City Code § 30-8.8
Corpus is an independent public-information project, not the official City of Gainesville website. Stable reference: corpuslaw.us/code/dd2a4e10-3b8f-469d-811c-c2a3b7553598
Sec. 30-8.8. - Tree preservation during development and construction.
A. Barriers required. Prior to clearing, demolition, or other construction activities, the city manager or designee or reviewing board shall determine which trees, if any, require protection. Protective barriers shall be constructed, as necessary, to prevent the destruction or damaging of regulated trees that are located within 50 feet of any construction activity or storage of equipment and materials. Trees identified for preservation which are destroyed or severely damaged shall be mitigated in accordance with section 30-8.7 prior to issuance of a certificate of occupancy or use. To avoid conflicts between barrier placements and demolition and construction activities, barriers shall be drawn to scale on the demolition, grading and paving sheets of the development plan. B. Barrier zones. All regulated trees in areas of demolition or construction that have not been permitted nor designated for removal by either the terms of the permit or approved development order shall be protected by barrier zones erected and inspected prior to construction of any structures, road, utility service or other improvements. Barricades shall comply with the following: 1. Protective barriers shall be plainly visible and shall create a continuous boundary around trees or vegetation clusters in order to prevent encroachment by machinery, vehicles or stored materials. To further protect tree roots, a layer of wood chips at least eight inches thick shall cover the soil within the barricade. Barricades shall be at least three feet tall and shall be constructed of either wooden corner posts at least two by four inches buried at least one foot deep, with at least two courses of wooden side slats at least one by four inches with colored flagging or colored mesh attached, or constructed of one-inch angle iron corner posts with brightly colored mesh construction fencing attached. High quality heritage trees shall be protected by galvanized chain link fencing a minimum of 48 inches high, 11.5-gauge wire, two and three-eighths inch mesh size secured with one and seven-eighths inch line posts no further than ten feet apart secured at a depth of three feet below soil line. Corners shall be secured with two and three-eighths inch line posts secured to a depth of four feet below soil line. 2. Barriers shall be placed at the greater of the following: a. At or outside the dripline for all heritage and champion trees and all regulated pine and palm trees; b. At a minimum of two-thirds of the area of the dripline for all other regulated species; or c. At the tree root plate. 3. If complying with the above placement of barriers is found to unduly restrict development of the property, the city manager or designee, or the appropriate reviewing board may approve alternative barrier placements or methods of protection provided that at least 50 percent of the area under the canopy dripline remains undisturbed (no grade change or root cut) and further provided that there shall be no disturbance to the tree root plate. Protective barriers may not be removed or relocated without such approval. 4. No trenching allowed within the protective barrier zone. Hand dig to install utility if approved by city manager or designee. Where roots greater than one inch in diameter are damaged or exposed, they shall be cut cleanly and re-covered with soil within one hour of damage or exposure. 5. Protective barriers shall remain in place and intact until such time as landscape operations begin. If construction needs dictate a temporary removal (for less than 24 hours), the city manager or designee, may approve or deny the temporary removal of protective barriers. 6. Landscape preparation in the protected area shall be limited to shallow discing of the area. Discing shall be limited to a depth of four inches unless specifically approved otherwise by the city manager or designee. 7. No building materials, machinery or harmful chemicals shall be placed within protective barriers, except short-duration placements of clean fill soil that will not harm the tree. Such short-duration placements shall not exceed seven calendar days. The city manager or designee shall be notified of the dates the short duration placement will begin and end. The original soil grade that existed within the protected areas prior to the placement of such fill shall be restored. 8. The American National Standards Institute A-300 Part V: Management of Trees and Shrubs During Site Planning, Site Development, and Site Construction or other nationally recognized arboricultural standards approved by the city manager or designee shall be used as guidelines for tree protection, planting, pruning and care during development and construction. C. Preservation generally. Trees may be preserved on development sites in locations where a new tree would be required. Credit for the preservation of such a tree will be given if the requirements listed below are met. During construction, if the requirements are not being met and/or the preserved tree is unlikely to survive in satisfactory condition, the owner shall apply for a tree removal permit in accordance with the requirements of this code. 1. Fifty percent of the area within the dripline of the tree shall be naturally preserved, both above- and below-ground. Under no circumstances shall permission be given for any construction activity within the tree root plate. The 50 percent protection zone shall include the entire tree root plate. Landscape materials are permitted within the 50 percent protection zone but not within the tree root plate. Within the 50 percent protection zone there shall be no alteration to the existing grade, no trenching or cutting of roots, and no storage of materials or fill. No heavy equipment shall be permitted within the protection zone. All work shall be done by hand. There shall be no compaction of the soil, as from heavy construction equipment, and no concrete, paint, chemicals or other foreign substances placed within this protection zone. 2. The city manager or designee may approve paving blocks within the protection zone, provided that all work is done by hand (no machinery), and that the soil area under the pavers is not compacted beyond the bulk density limits of 1.40 g/cc in clay, 1.50 g/cc in loam, or 1.70 g/cc in sand. No lime rock or other material shall be used underneath the pavers. Pavers may not be placed within the tree root plate. 3. There shall be no evidence of active insect infestation potentially lethal to the trees and no damage from skinning, barking or bumping. 4. The root plate of regulated trees within the public right-of-way should not be impacted by adjacent development, even where the tree root plate encroaches on the private property. The installation of new utilities or improvements to public utilities required to serve the development should not require the removal of trees on the public right-of-way, where the required separations from the utilities can be met. 5. If any preserved tree is not alive and healthy three years after the certificate of occupancy is granted, it shall be removed and replaced with the tree or trees which originally would have been required by this code. The area that was preserved to accommodate the preserved tree shall be maintained in an unpaved condition and the replacement trees established in this area. 6. The city shall maintain, and make available to the public, descriptions and illustrations of tree preservation and protection practices which will assist in assuring that preserved trees survive construction and land development. D. Inspections. The city manager or designee shall conduct periodic inspections of the site before work begins and/or during clearing, construction and/or post-construction phases of development in order to ensure compliance with these regulations and the intent of this section. E. Denial; conditions. The reviewing board or city manager or designee may deny a proposal for development because one or more champion or high quality heritage trees have not been preserved or adequately protected, or may require special conditions of approval that may include but are not limited to the following: 1. Requiring the trees to be protected with chain link barricades. 2. Requiring a soil aeration system in the vicinity of tree roots as needed, particularly where fill will be added over roots of preserved trees or where compaction may reduce the availability of water and oxygen to tree roots.
Ask a question about Gainesville law
Corpus searches the Gainesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.
