§ 470.309 — Distribution boxes
Jacksonville Ordinance Code (Supp. No. 6, Update 2: codified through Ordinance No. 2026-492-E, enacted July 28, 2026) · Jacksonville Ordinance Code § 470.309
Corpus is an independent public-information project, not the official City of Jacksonville website. Stable reference: corpuslaw.us/code/4bbc5164-301f-44d3-a320-8818ac65f8b5
Sec. 470.309. - Distribution boxes.
If two or more laterals or lines of drain pipes are required, a distribution box shall be provided between the septic tank and the absorption field or bed. The distribution box shall be constructed of durable material, shall be watertight, of adequate structural strength, and of sufficient size to accommodate the required number of lines and drain pipe. Each drainfield line shall connect individually to the distribution box. The invert of the inlet to the box shall be at least one inch above the invert of the outlets, and, the invert of all outlets shall be level.
(Ord. 70-650-526; Ord. 71-397-181; Ord. 83-591-400, § 1)
Ask a question about Jacksonville law
Corpus searches the Jacksonville sections it holds and shows the ones that match, with their citations. Free, no sign-in.
