For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 34-415 — Nonresidential design standards

Code of Ordinances of the City of Miami Gardens, Florida (Codified through Ordinance No. 2026-005-494, adopted February 25, 2026 (Supp. No. 19)) · Miami Gardens Code of Ordinances § 34-415

Corpus is an independent public-information project, not the official City of Miami Gardens website. Stable reference: corpuslaw.us/code/3b9716e3-dd49-4836-8136-e27e592c5335

Sec. 34-415. - Nonresidential design standards.

The following standards apply to nonresidential buildings. All buildings and accessory structures shall be designed to be compatible in scale and massing to the neighborhood character and buildings and shall be subject to the following design standards: (a) Commercial and mixed-use design standards. (1) Overall height and roof form. Individual buildings shall vary in overall height and not be contained in a single volume of continuous height. (2) Building massing and articulation. a. Horizontal articulation. Buildings shall provide horizontal articulation architectural features every 40 linear feet or less along the facade. This means that the façade should not have long, uninterrupted stretches, but rather should be broken up into smaller segments. 1. Techniques for achieving horizontal articulation. I. Horizontal projections or recessions of at least two feet. These elements add depth to the façade and create shadow lines, helping to break up the massing. II. Change of material or texture. Using different materials or textures along the façade can visually separate sections of the building and add visual interest. III. Change in window size or placement. Varying the size and placement of windows can create rhythm and variation along the facade, contributing to its articulation. IV. Color use. Color alone should not be used to substitute architectural features. While color variation is encouraged, it should be used in combination with other elements to reinforce building modulation. This ensures that the façade's visual interest is not solely reliant on color but is instead achieved through architectural design. [image omitted; see the official code] [image omitted; see the official code] Figure 6 - Horizontal Articulation b. Vertical articulation. Buildings shall feature moderation in the vertical surface plane to avoid having flat, monotonous vertical facades. Instead, they should incorporate elements that add visual interest and depth to the building's exterior. 1. Techniques for achieving vertical articulation. The vertical plane moderation shall be of minimum height to be clearly visible from the street, in scale with the building, and, significant enough to produce shadow lines against the building. Color alone shall not be used to substitute architectural features. Color variation shall be used in combination with other elements to reinforce building modulation. Methods for achieving moderation in the vertical surface plane, include the following: I. Building projections or recessions of at least two feet. These can create shadow lines and add depth to the facade. II. Transparent storefronts. Providing clear windows at ground level enhances transparency and interaction between the building and the street. III. Awnings and entrance canopies. These architectural features not only provide shelter but also break up the vertical plane and create a sense of entry. IV. Color or texture changes coinciding with vertical elements. Using different colors or textures can visually separate sections of the building and add visual interest. V. Change of material or texture on the ground floor. The ground floor may feature a distinct change in material or texture compared to the upper floors. This helps to visually separate the ground level where commercial or public spaces are located from the upper floors. [image omitted; see the official code] Figure 7 - Vertical Articulation c. Façade treatment. Façade treatment in buildings, shall enhance the visual appeal, pedestrian experience, and compatibility with surrounding areas. 1. Maximum blank wall area. The maximum continuous area of blank wall on any exterior facade facing residential use, public or private streets shall be 25 feet. Blank wall area is defined as portions of the façade without openings (windows or doors), architectural features greater than one foot in depth, or substantial material changes. 2. Modular design required for large façades. Front façade building expanses larger than 100 feet should be broken up into smaller modules of 25 to 50 feet. This modular design approach helps to support pedestrian scale and prevent long, repetitive stretches of facade, contributing to a more visually interesting streetscape. [image omitted; see the official code] Figure 8 - Modular Design 3. Distinctive building base, middle, and top. Buildings exceeding four stories are required to provide distinct architectural treatment for the base, middle, and top portions of the façade. I. Base. The first story should feature architectural elements that provide vertical separation from the middle and upper portions of the building. These elements may include changes in material, texture, or color, variation in window shape and treatment, and pedestrian-oriented features such as street connections, gardens, courtyards, or high transparency. II. Middle. This section of the building should maintain visual interest and compatibility with the base and top portions. III. Top. The uppermost portion of the building should also be treated architecturally to enhance the overall appearance and avoid a monotonous or undifferentiated façade. [image omitted; see the official code] Figure 9 - Distinctive Base, Middle and Top d. Articulated building entrance. The primary building entrance of each building shall be designed as a clearly defined and demarcated standout architectural feature of the building. The entrance shall be easily distinguished from secondary entrances and the regular façade treatment of the building. Several architectural elements can be used to guide pedestrians and visitors to the main entrance and create a sense of arrival as follows: I. Recessed or projected mass or form element. Creating a recessed or projected area around the main entrance can help to visually emphasize its importance and draw attention to it. II. Corner entry with doors and storefront. Placing the main entrance at a building corner, with doors and storefront windows, can make it a prominent and inviting feature. III. Roof variation. Incorporating variations in the roofline above the main entrance can help to highlight its location and add architectural interest. IV. Awnings or roof overhangs. Installing awnings or roof overhangs above the main entrance can provide shelter and define the entrance area, making it more visually distinct. (3) Building materials. Development shall propose high quality building materials that promote longevity and aesthetically pleasing design. Recommended exterior building materials include colored and/or textured concrete, stucco, glass, cladding materials, brick or stone veneers, and pre-cast high quality synthetic veneers. Design materials must be consistent on all primary facades visible from public or private streets. Accessory buildings shall be constructed of the same materials as approved for the principal building. (4) Fenestration. Windows should be grouped rather than evenly spaced across the facade of the building and should include variation in shape and size. Seventy-five percent minimum of any building façade facing a public or private street should be transparent windows or doors with clear sight lines into the structure. Street level windows and doors should be recessed or receive special design consideration to differentiate them from the rest of the building and to add visual variety to the streetscape. Blank walls shall be avoided and shall not exceed 25 feet vertically and horizontally. Reflective surfaces and bars shall be prohibited. (5) Pedestrian and vehicular use areas. Development shall incorporate appropriate street and sidewalk widths and connectivity between buildings, streets and parking areas. Paving palette shall include brick pavers and/or stamped concrete to visually separate pedestrian areas from vehicular use areas. Similarly, when curb cuts are provided, different paving materials shall be used to indicate to drivers that their vehicle is entering a pedestrian zone. (6) Site furnishings. Furnishings such as trash receptacles, benches, bicycle racks, lighting fixtures and pavement treatments are required in accordance with this chapter. The design of each of these elements is subject to approval by the planning and zoning director or designee. (7) Accessory structures and uses. All accessory structures shall be subject to development and design standards set forth in article X of this chapter. Service areas, loading areas and associated activities shall be located to the rear of buildings and screened from a public right-of-way and residential use. (8) Mixed use regulations. Mixing of uses is optional. Whenever a development will contain a mix of residential and commercial uses, the mixing of uses shall be subject to the provisions of this section. a. Minimum use mix requirements. i. Residential: Forty percent of gross floor area or four dwelling units, whichever is greater. ii. Commercial/office: Fifteen percent of gross floor area. iii. Ground story retail/service/entertainment uses: Ten percent of gross floor area. b. Vertical mixed-use requirement. The different uses must be combined within the same building. Horizontal mixed-use development, consisting of single-use buildings on a parcel is not be permitted. c. Ground floor retail and public uses. Ground floors should be dedicated to retail shops, restaurants, cafes, or other public-facing businesses. d. Middle and upper floors uses. The middle and upper floors of a vertical mixed-use building must house office spaces, dwelling units, or hotel rooms, provided that dwelling units, hotel rooms and offices shall not be located in the same story unless they are physically separated and served by separate elevators and stairways, and separate ground story lobbies. e. Master plan required. Mixed-use development is subject to master plan approval for such mixed use, provided that any use that the administrative official finds is incompatible with residential use pursuant to the following criteria shall require special exception approval. An affirmative finding for any of the following criteria shall require a special exception: 1. The operation of the use involves amplified sound, use of power tools, pounding, banging, testing or running of engines, or other potentially disruptive source of noise or vibration. 2. The use involves the assembly of a large number of people at any one time, in such a way that there is resulting noise, traffic, or loss of privacy that may be intrusive and therefore incompatible with residential use. 3. The use produces odors, fumes, smoke or vapor that is generally considered offensive or unpleasant, and which may be detectable from adjacent dwelling units. 4. The use employs lighting that would generate glare or lighting levels that are excessive in an urban residential environment. 5. The use involves unsightly loading areas, overhead doors, outdoor storage, parking of commercial vehicles prominent, or prominent mechanical equipment areas. 6. The use involves the use or storage of hazardous materials. (b) Industrial and work-live loft design standards. (1) Overall height and roof form. Individual buildings shall vary in overall height and not be contained in a single volume of continuous height. (2) Building massing and articulation. a. Horizontal articulation. Buildings must incorporate horizontal articulation architectural features at intervals of every 50 linear feet or less along the façade. This means that the façade should be divided into smaller segments to avoid long, uninterrupted stretches. 1. Techniques for achieving horizontal articulation. I. Horizontal projections or recessions of at least two feet. These elements create depth and shadow lines, helping to break up the massing of the building façade. II. Change of material or texture. Using different materials or textures along the façade can visually separate sections of the building and add visual interest. III. Color use. Color alone should not be used to substitute architectural features. While color variation is encouraged, it should be used in combination with other elements to reinforce building modulation. This ensures that the facade's visual interest is not solely reliant on color but is instead achieved through architectural design. [image omitted; see the official code] Figure 10 - Horizontal Articulation b. Vertical articulation. Buildings must incorporate moderation in the vertical surface plane. The vertical plane moderation should be of sufficient height to be clearly visible from the street and produce shadow lines against the building. The architectural elements used for vertical articulation should be in scale with the building and proportionate to its size. The moderation should be significant enough to be noticeable and enhance the building's overall appearance. 1. Techniques for achieving vertical articulation. I. Building projections or recessions of at least two feet. These elements create depth and shadow lines, helping to break up the vertical plane of the façade. II. Color or texture changes coinciding with vertical elements. Using different colors or textures along the façade can visually separate sections of the building and add visual interest. III. Color use. Similar to horizontal articulation, color alone should not be used to substitute architectural features. Instead, color variation should be used in combination with other elements to reinforce building modulation and create visual interest. [image omitted; see the official code] Figure 11 - Vertical Articulation c. Façade treatment. The maximum continuous area of blank wall for front façade, side façade or any portion of a building fronting residential use, public or private street, shall be 50 feet to avoid monotonous design and provide visual relief. Blank wall area is defined as the portion of any exterior façade that do not include openings such as windows and doors, architectural features greater than one foot in depth or substantial material change. d. Articulated building entry. The primary entrance for each tenant shall be designed as a clearly defined and demarcated standout architectural feature of the building. The entrance shall be visually prominent and easily distinguished from secondary entrances and the regular façade treatment of the building. This may be accomplished for instance, through architectural detailing, providing a recessed or projected mass or form element where the entry is located, a corner entry, roof variation, incorporation of awnings or roof overhangs. (3) Building materials. Development shall propose high quality building materials that promote longevity and aesthetically pleasing design. Recommended exterior building materials include colored and/or textured concrete, stucco, glass, cladding materials, brick or stone veneers, and pre-cast high quality synthetic veneers. Design materials must be consistent on all primary façades visible from public or private streets. Accessory buildings shall be constructed of the same materials as approved for the principal building. (4) Pedestrian and vehicular use areas. Development shall provide clear and safe pedestrian access, including appropriate street and sidewalk widths and connectivity between buildings, streets and parking areas. Landscape berms shall be used to buffer parking areas from the street. (5) Site furnishings. Furnishings such as trash receptacles, bollards, lighting fixtures and pavement treatments are required in accordance with this chapter. The design of each of these elements is subject to approval by the planning and zoning director or designee. (6) Accessory structures and uses. All accessory structures shall be subject to development and design standards set forth in article X of this chapter. Service areas, loading areas and associated activities shall be located to the rear of buildings and screened from a public right-of-way and residential use. (7) Work-live loft additional design standards. Work-live lofts spaces shall be functional and conducive to both living and working activities. While specific elements can vary depending on the nature of the development, the following additional standards shall apply: I. No separate outside entrance. Live-work lofts shall be accessed from inside the business. No separate outside entrance shall be permitted. II. Flexible space. Design should allow for flexibility in how the space is used, with adaptable layouts that can accommodate different types of businesses or residential needs. III. Soundproofing. Effective soundproofing measures shall be provided to minimize noise transfer between the residential and commercial areas and to create a conducive environment for work and rest. IV. Natural light. Maximize natural light with large windows and skylights to enhance the comfort and productivity of both living and working areas. V. Amenities. Live-work units should include basic amenities such as a kitchen, bathroom, and sleeping area for residential use, as well as any necessary facilities for commercial activities. VI. Accessibility. Design should comply with ADA requirements. VII. Outdoor space. Where possible, live-work lofts should include access to outdoor space such as balconies, terraces, or communal courtyards to enhance quality of life for residents and provide opportunities for outdoor work or relaxation. VIII. Community integration. Design should facilitate interaction and integration with the surrounding community, such as through storefront windows, pedestrian-friendly entrances, and shared public spaces. IX. Residential living area. The residential living area shall be incidental and subordinate to the business or workspace area a) The residential living area shall not occupy more than ten percent of the workspace or business area and shall not be larger than 600 square feet, whichever is less. b) Residential unit shall be accessed from inside the business. No separate outside entrance shall be permitted. c) Where there are multiple businesses within a single building or structure, only one residential living area shall be permitted per business. d) The residential living space shall be contained within the same structure as the workspace and must be occupied by the business operator. No portion of the unit may be rented or sold separately. X. Required parking. Parking must be provided in accordance with article XII of this chapter. [image omitted; see the official code] Figure 12 - Work Live Loft Example

(Ord. No. 2010-10-218, § 2(13-30), 4-7-2010; Ord. No. 2011-21-263, §§ 4, 5, 10-5-2011; Ord. No. 2025-002-482, § 2(Exh. A), 1-22-2025)

Ask a question about Miami Gardens law

Corpus searches the Miami Gardens sections it holds and shows the ones that match, with their citations. Free, no sign-in.