§ 34-417 — Lighting standards
Code of Ordinances of the City of Miami Gardens, Florida (Codified through Ordinance No. 2026-005-494, adopted February 25, 2026 (Supp. No. 19)) · Miami Gardens Code of Ordinances § 34-417
Corpus is an independent public-information project, not the official City of Miami Gardens website. Stable reference: corpuslaw.us/code/112340ec-75fc-4241-8ad6-d2f281c27469
Sec. 34-417. - Lighting standards.
Purpose and intent. It is the purpose of this section to establish regulations regarding exterior lighting for development and redevelopment; to integrate lighting within developments to enhance the aesthetic appearance of the city; to ensure the safety of residents and visitors; to reduce energy costs; to minimize light pollution and protect dark skies; and to minimize adverse visual impacts upon drivers of vehicles. Lighting is not intended to be used as advertising or to draw attention to the building, grounds or uses associated with such building. This section is applicable to all exterior lighting in the city and within parking garage structures, excluding lighting for signage which is regulated in a separate section of this chapter. (1) Height, intensity and design standards. a. Height standards. For the purposes of these regulations, the mounting height of a light fixture shall be defined as the vertical distance from grade elevation of the surface being illuminated to the bottom of the light fixture. 1. Light fixtures shall not exceed 25 feet in height in vehicle-use areas. 2. Light fixtures shall not exceed 12 feet in height in pedestrian areas. 3. Building and accent light fixtures shall not be installed above the roofline. b. Footcandle standards. The minimum and maximum average footcandle range and maximum footcandle permitted for each lighting zone in residential and nonresidential areas shall be those listed in table 1 in this section. Table 1: Footcandle Standards (1) Lighting Zone | Minimum Average Maintained | Maximum Average Maintained | Maximum Allowed Service station canopy (2) | 20.0 fc | 30.0 fc | 60.0 fc Vehicular-use areas | 1.5 fc | 10.0 fc | 10.0 fc Pathways, pedestrian open spaces, and outdoor seating (3) | 1.0 fc | 10.0 fc | 10.0 fc Landscape buffers to a property line | N/A | 2.0 fc | 5.0 fc Property line | N/A | 2.0 fc (4) | 5.0 fc (4) Parking garage (5) | 3.0 fc | 50.0 fc | 60.0 fc ATMs | 10.0 fc | 20.0 fc | 20.0 fc Public streets | 1.0 fc | N/A | N/A Private streets | 0.6 fc | N/A | N/A Outdoor recreation and sports facilities | (6) | (6) | (6) Recreational areas | (7) | (7) | (7) Table Notes. (1) Unless mandated by other state or federal standards. (2) These standards shall only apply under the service station canopy and up to 15 feet from the outside edge of the canopy. (3) Pathways, pedestrian areas, and outdoor seating abutting another lighting zone with a greater footcandle 4 - requirement may include lighting levels consistent with the adjacent zone. Underpasses are required to illuminate a minimum of 2.0 fc. (4) No light spillover shall be permitted on any point inside the adjacent residential property. (5) During the daytime, the vehicular and pedestrian exits and entrances must maintain a minimum average of 50 fc. Stairwells must maintain a minimum average of 20 fc 24 hours a day. Ramps, drive aisles, and all other areas of the garage must maintain a minimum average of 3.0 fc. (6) Outdoor lighting for sport facilities such as tennis courts, stadiums, soccer and ball fields are exempt from the footcandle standards in Table 1; however, lighting at sports facilities shall not exceed IESNA-recommended practices for the type of field and use, and shall meet standards for light spillover and glare for residential properties in this section. (7) In those areas designated as recreational areas, or within preserves, pedestrian paths or multi-purpose paths, or other areas that are either gated or secured or are closed after dusk, lighting requirements shall be determined, as part of a development order approval, by the administrative official in consultation with the Police Department in order to provide adequate security lighting for the recreational area. _____ (2) Design standards. a. Street lighting for public and private rights-of-way must be designed in accordance with either FPL, FDOT, or IESNA-recommended practices if required, and must also meet the minimum requirements set forth in Table 1. b. The location and design of lighting for parking garages shall be consistent with IESNA standards. c. Proposed lighting installations that are not covered by the provisions in this section may be approved only if the city council finds that they are designed to minimize glare, do not direct light beyond the boundaries of the area being illuminated or onto adjacent properties or streets, and do not result in excessive lighting levels. IESNA standards shall be used to determine the appropriate lighting design. d. All lighting must protect dark skies. (3) General standards. a. Light fixtures. Light fixtures shall be installed such that the source of light does not shine directly into adjacent residential districts, as provided below: 1. Freestanding light poles. Freestanding light poles located within 100 feet of a residential zoning district shall be a cutoff luminaire or equivalent, with a maximum angle of 90 degrees. 2. House shields. House shields, or equivalent, shall be required for all fixtures located within 25 feet of a residential district. 3. Flood lights and security lighting. Flood lights, security lighting, or similar equipment shall not be directed toward any residential district. b. Glare. Off-site light spillover shall not produce a glare which creates a safety or traffic hazard. c. Landscaping. Conflict between landscaping and lighting installations shall be minimized or eliminated. Light fixtures installed in parking lots must provide the required lumen coverage and not be obstructed by the location and future height of existing or proposed trees or other landscaping. d. Canopy lighting. Canopy light fixtures, such as service station lighting, shall be aimed downward and shall be fully recessed or fully shielded so as to ensure that the light fixture is not visible from public rights-of-way or adjacent properties and does not cause glare. All light emitted by an under-canopy fixture shall be substantially confined to the ground surface directly beneath the perimeter of the canopy. As an alternative to recessed lighting, indirect lighting may be used when light is directed upward and then reflected down from the underside of the canopy. In this case, light fixtures shall be shielded so that direct illumination is focused exclusively on the underside of the canopy. No lighting shall be permitted on the top or sides of the canopy, excluding approved internally-illuminated signs. e. Flag poles. Flag poles may be illuminated by an approved fully-shielded spotlight fixture or fixtures provided they do not create off-site glare or light spillover above the limits established in table 1 in this section. The fixture shall be placed as close to the base of the flag pole as possible. f. Maintenance. Fixtures and lighting systems used for safety and security shall be in good working order and be maintained in a manner that serves the original intent of the system at all times. Accent and building lighting shall be maintained to keep the desired aesthetic appearance. (4) Building and accent lighting. a. Lighting of buildings. All exterior building lighting, including entry, facade, rooftop, security, and accent lighting shall conform to the requirements provided below: 1. Permitted lighting. Exterior lighting may be used to illuminate a building and its grounds for safety purposes, so long as the lighting is done in a manner that is aesthetically pleasing compatible with the overall surroundings, and in compliance with this section. 2. Compatibility. Lighting shall be installed in a manner that is compatible with the neighborhood and adjacent development, and protects dark skies. 3. Fixtures. All fixtures used in exterior building lighting are to be selected for functional and aesthetic value. Light fixtures shall not be directly beamed upward or toward adjacent properties and pedestrian areas. 4. Accent lighting for nonresidential and multifamily buildings. Accent lighting for architectural and/or aesthetic purposes is permitted subject to the following restrictions: (i) All upward-aimed lights shall be fully shielded from projecting into the sky by eaves, roofs, or overhangs. (ii) Strings of lights or other similar accent lighting may be installed on trees and landscaping and on buildings below the roofline provided: Light strings shall not be suspended horizontally between any buildings, walls, fences, trees, or shrubs. Strings of light shall contain only low wattage clear bulbs (less than 100 lumens) without interior or exterior frosting, colors or reflectors. (iii) Integration with form. Lighting which mimics the architectural lines of the building or part of the building, unless otherwise allowed in this section, shall only be permitted by approval of an administrative petition. b. Exemptions. Single-family residential homes are exempt from the accent requirements herein, provided the lighting does not create light spillover or glare on adjacent residential properties or public rights-of-way. (5) Seasonal lighting. a. Nonresidential, multifamily and mixed-use zoning districts. Seasonal exterior lighting is permitted without a permit provided it does not exceed 45 days during a calendar year, and shall not be suspended between any buildings, walls, fences, trees, or shrubs. Such lighting cannot produce spillover, glare or negatively impact dark skies. b. Single-family residential zoning districts. Seasonal exterior lighting is permitted but cannot be illuminated in excess of a total of 45 days during a calendar year. (6) Lighting plans. Plans for illumination of buildings and other areas shall be submitted at the time of building permit or when more than 50 percent of the existing site lighting is being modified (including changes to lumens). Lighting plans shall comply with the standards listed below: a. Design. Plans shall be prepared and sealed by an engineer registered in the state. b. Plans. Lighting plan or plans, including photometric plans, shall include the following information: 1. Property site plan. 2. Vehicular and pedestrian access and circulation. 3. Adjacent property lines, existing uses and future land use map and zoning district designations. 4. Plan and elevation view of all fixtures, including pole and wall-mounted. 5. Height of all fixtures. 6. Photometric data and statistical analysis, including footcandle values, maximum to minimum uniformity ratio, average initial or average maintained footcandles, minimum footcandles, maximum footcandles, points of calculation for footcandles at minimum ten-foot intervals on site and ten feet beyond the property line, and any other information required by the city engineer. 7. The location and description, including the mature height, of all existing and proposed trees, and the location of light fixtures on both adjacent properties and the street rights-of-way within 50 feet of the subject property. 8. Light fixture data, including manufacturer, wattage and lighting type. 9. All plans must be certified by a registered architect or engineer as providing illumination in accordance with the applicable minimum standards set forth in this section and that subsequent construction will comply with the approved lighting plan. 10. Lighting installations cannot be placed in permanent use until a letter of compliance from a registered professional architect or engineer has been provided stating that the installation has been field checked and meets all specifications set forth on the approved photometric plan. (7) Method of measurement. The light meter sensor shall be read at ground level or the established grade in a horizontal position. Readings shall be taken only after the light source has been exposed long enough to provide a constant reading. Measurements shall be taken after dark with the light sources to be measured on and off. The difference of the two readings shall be compared to the permitted illumination level for each lighting zone. (8) Street lighting. a. Decorative lighting. The city administrative official, as part of a development order approval, may require installation of decorative street lighting consistent with the style of existing fixtures on roadways adjacent to the property. b. Street lighting must illuminate public sidewalks along identified corridor roads to the level established for pathways in table 1. c. Private streets. Street lighting shall meet the public and private street lighting standards set forth in table 1 for all streets within and adjacent to a private development. (9) Prohibited lighting. The following types of permanent outdoor light fixtures are prohibited: a. Any upward-oriented lighting unless otherwise provided for in this section. b. Searchlights, beacons and laser-source light fixtures. c. Any lamp or bulb not within a light fixture (except for seasonal, accent, building lighting or landscape ornamental lighting) visible beyond the property line on which it is located. d. Exposed or visible neon light tubing. e. Any lighting utilized as or associated with prohibited signage as set forth in this chapter.
(Ord. No. 2010-10-218, § 2(13-50), 4-7-2010)
Ask a question about Miami Gardens law
Corpus searches the Miami Gardens sections it holds and shows the ones that match, with their citations. Free, no sign-in.
