§ 5-27 — Electrical safety requirements

Code of the City of Miramar, Florida (Supp. No. 105: codified through Ordinance No. 26-10, adopted July 8, 2026) · Miramar City Code § 5-27

Corpus is an independent public-information project, not the official City of Miramar website. Stable reference: corpuslaw.us/code/52459a83-e02f-466f-9dd8-d84c6cd11201

Sec. 5-27. - Electrical safety requirements.

(a) General requirement. All electrical wiring, equipment and apparatus used for amusement devices or for lighting shall be properly and legally installed, operated and maintained in accordance with the city's building code. (b) Protection of employees. No employees shall be suffered or permitted to work in such proximity to any part of an electric power circuit that he/she may contact the same in the course of his/her work unless he/she is protected against shock by de-energizing the circuit, grounding it, or guarding it by effective insulation. If protection is supplied by de-energizing the circuit, the switch controlling the circuit shall be locked out to prevent inadvertent closing. (c) High voltage lines. The outlets of electric power lines carrying more than one hundred twenty (120) volts shall be clearly marked to show their voltage. (d) Transformers. All electrical transformer sub-stations shall be properly enclosed and proper warning signs shall be posted. (e) Outdoor apparatus and wiring. Electrical apparatus and wiring located outdoors shall be of such quality and so constructed or protected that exposure to weather will not interfere with its normal operation. (f) Elevated lines. Elevated power lines crossing access or other roads within the grounds of a carnival, fair or amusement park shall be so suspended as to provide minimum vertical clearance of eighteen (18) feet from the road surface and minimum horizontal clearance of three (3) feet on each side of the normal passage space of vehicles. (g) Suspended electric wiring. Temporary electric wiring, if suspended, shall be so supported that its protective insulation will not be damaged. (h) Grounding. Temporary electric installations shall be properly grounded. (i) Exposed conductors. Bare wires and other uninsulated current-carrying parts shall be guarded against inadvertent contact by means of proper location or by a fence or other barrier. (j) Overcurrent protection. Conductors shall be provided with overcurrent protective devices according to load. No such device shall be installed in neutral or grounding conductors. (k) General grounding. Where electrical power is supplied for an amusement device or a temporary structure by a privately operated generating system, the generator and all equipment shall be properly grounded if the system incorporated a ground. (l) Receptacles and caps. All receptacles and attachment caps shall be of the grounding type. (m) Grounding of devices. Each electrically powered amusement device shall be effectively grounded. The grounding shall be made effective as to all noncurrent carrying metal parts which may become energized and which are exposed to contact by any person. An effective ground shall be one (1) having a resistance of twenty-five (25) ohms or less. (n) Abrasion protection. Wiring laid on surfaces traversed by vehicular or pedestrian traffic shall be adequately protected against wear and abrasion. (o) Master switch. Each electrically operated amusement device not designed to be controlled directly by the passenger shall be provided with a disconnect power switch placed within easy reach of the operator.

(Code 1964, § 3A-28)

Ask a question about Miramar law

Corpus searches the Miramar sections it holds and shows the ones that match, with their citations. Free, no sign-in.