Sec. 9-77. - Fire flow requirements.
(a) Intent. The intent of this section is to assure an adequate water supply for fire suppression by establishing minimum flow rates required to control and extinguish fires that may occur within prescribed occupancy classifications. The requirements of this section shall be applicable to public and private water systems, including individual properties and land development projects. (b) Required fire flow. (1) [Generally.] The "required fire flow" is the rate of flow needed for fire fighting purposes to confine a major fire to the buildings within a block or other contiguous group. The determination of this flow depends upon the size, construction, occupancy and exposure of buildings within and surrounding the block or group of buildings, and upon the existence of automatic sprinkler protection. The determination of required fire flow in each case shall be made by the city engineer according to the criteria established by this section and by the Guide for Determination of Required Fire Flow, Published by the Insurance Services Office, December 1974 edition, which is adopted and incorporated herein by reference. Note: Buildings located in commercial, industrial or multi unit residential districts may reduce fire flow requirements by up to fifty (50) percent for complete automatic sprinkler protection. Automatic sprinkler installations must be in accordance with NFPA standards as adopted by the City Code. (2) Supplemental flow systems. If the minimum fire flow requirements set out in this section cannot be met by the water supply utility, then the applicant for a building permit shall be responsible for installing the necessary provisions to improve the system to an acceptable level as determined by the city engineer. (3) Main sizes. Main sizes and system patterns shall be subject to approval of all applicable agencies pursuant to fire and normal flow demand criteria. (4) Distribution systems. The supply mains shall be of adequate size and have properly arranged connections to the arterial mains which shall extend throughout the systems and have numerous connections to the secondary feeders that supply the minor distribution. All distribution systems shall be designed to reduce dead-end mains and provide a loop for new and existing mains. Note: Dead-end mains shall not exceed six hundred (600) feet in length. This requirement may be waived by the fire chief or designee where deemed unnecessary or impractical for the safety of the public. (c) Testing fire flow. (1) The City of Miramar Fire-Rescue Department has established fifty-five (55) psi as the maximum allowable normal operating pressure (static pressure) when computing the available water supply for all new automatic sprinkler systems.
(Ord. No. 97-35, § 1, 6-4-97)
Ask a question about Miramar law
Corpus searches the Miramar sections it holds and shows the ones that match, with their citations. Free, no sign-in.