§ 16.40.050.16.6 — Decks and patios in coastal high hazard areas (V/VE)

Code of Ordinances, City of St. Petersburg, Florida (Supp. No. 55, Update 2: codified through Ordinance No. 646-H, adopted August 27, 2026) · St. Petersburg City Code § 16.40.050.16.6

Corpus is an independent public-information project, not the official City of St. Petersburg website. Stable reference: corpuslaw.us/code/5d3069af-b719-4a56-b2ff-0ae19ec85770

16.40.050.16.6. - Decks and patios in coastal high hazard areas (V/VE).

In addition to the requirements of the Florida Building Code, and ASCE 24, in coastal high hazard areas, decks and patios shall be located, designed, and constructed in compliance with the following: 1. A deck that is structurally attached to a building or structure shall have the bottom of the lowest horizontal structural member at or above the design flood elevation and any supporting members that extend below the design flood elevation shall comply with the foundation requirements that apply to the building or structure, which shall be designed to accommodate any increased loads resulting from the attached deck. 2. A deck or patio that is located below the design flood elevation shall be no more than four inches thick, shall be without reinforcement or turned down edges, shall be structurally independent from buildings or structures and their foundation systems, and shall be designed by a State registered design professional and constructed either to remain intact and in place during design flood conditions or to break apart into small pieces to minimize debris during flooding that is capable of causing structural damage to the building or structure or to adjacent buildings and structures, with no harmful diversion of floodwaters, wave runup, or wave deflection that would increase damage to adjacent buildings and structures. 3. A deck or patio that has a vertical thickness of more than four inches or that is constructed with more than the minimum amount of minor fill necessary for site drainage shall not be approved unless an analysis prepared by a qualified registered design professional demonstrates no harmful diversion or deflection of floodwaters or wave runup and wave deflection that would increase damage to the building or structure or to adjacent buildings and structures or that causes water runoff onto abutting properties. 4. A deck or patio that has a vertical thickness of 12 inches or less and that is at natural grade or on nonstructural minor fill material that is similar to and compatible with local soils and is the minimum amount necessary for site drainage may be approved without requiring analysis of the impact on diversion of floodwaters or wave runup and wave reflection.

(Ord. No. 743-L, § 1, 7-15-2021)

Ask a question about St. Petersburg law

Corpus searches the St. Petersburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.