§ 25-316 — Design standards for small wireless facilities
Code of Ordinances, City of St. Petersburg, Florida (Supp. No. 55, Update 2: codified through Ordinance No. 646-H, adopted August 27, 2026) · St. Petersburg City Code § 25-316
Corpus is an independent public-information project, not the official City of St. Petersburg website. Stable reference: corpuslaw.us/code/78ac26bc-6069-4ed7-a8a6-846304187e25
Sec. 25-316. - Design standards for small wireless facilities.
(a) Design standards—General. Small wireless facilities and accessory equipment placed anywhere in the City right-of-way are subject to the following design guidelines: (1) Small wireless facilities may not extend more than ten feet above the utility pole upon which it is mounted. (2) A new pole is limited to the height of the tallest existing utility pole, as of July 1, 2017, located in the same right-of-way and within 500 feet of the proposed new pole. If there is no existing pole within 500 feet of the new pole site, the new pole is limited to 50 feet. (3) Above ground facilities must be located within the right-of-way where the shared property line between two parcels intersects the right-of-way boundary, or otherwise in a manner that demonstrates the least impact to access to private property. (4) Equipment boxes and other ground equipment located at grade must be located in areas with existing foliage or another aesthetic feature to obscure it from the view, to the greatest extent possible. The application must include a depiction of techniques utilized for camouflaging. (5) Equipment mounted to the exterior of a pole shall be a minimum of eight feet above finished grade, excluding the electric meter and disconnect switch. The external finish of the equipment cases shall generally match the color of the pole. All mounting and banding fixtures shall also match the color of the pole. Conduits mounted to an existing pole must match the pole color and be encased with a shroud cover. (6) New poles shall be located at or near roadway intersections or in alleys when possible. When mid-block locations are necessary, new poles shall be located near the property boundary line at the edge of the site or otherwise sited in a manner that demonstrates the least impact to access to private property. (7) Separation from driveways and hydrants. Above-ground communications facilities and utility poles shall be located at least ten feet from a driveway apron and at least 30 feet from a fire hydrant. (8) New poles shall be designed with conduit internal to the pole, with the exception of wood poles. Above the electric meter and disconnect switch, all conduit and wiring shall be located inside the pole. (9) New poles shall be consistent with the existing poles located in the same right-of-way and within 500 feet of the proposed new pole, unless approved otherwise by the POD. (10) Facilities shall not block or encroach into an existing or future public sidewalk paths as required in the City's Land Development Regulations. (11) Electric meters and disconnect switches shall be located on the side of the pole that is oriented in the same direction as the flow of vehicular traffic in the adjacent roadway. For example, if traffic flow is north-bound, then the equipment should be placed on the north side of the pole. Conduit leading to the electric meter box and disconnect switch shall generally match the color of the utility pole. (12) Grounding rods shall not extend above the surface elevation and the ground wire between the pole and ground rod must be inside an underground conduit. (13) All pull boxes shall be located outside of the sidewalk or pedestrian ramp. A concrete apron must be installed around all pull boxes located within the landscape area of the parkway. (14) All pull boxes must be vehicle load bearing, comply with FDOT standard specifications and be listed on the FDOT approved products list. (15) Small wireless facilities and accessory equipment shall meet all applicable historic preservation regulations required by the City's Historic and Archaeological Preservation Overlay Ordinance, including obtaining a certificate of appropriateness if necessary. (b) Design standards—Traditional zones, downtown center zones, and charter parks. Small wireless facilities and accessory equipment placed in the City right-of-way in an NT, CRT, CCT, or DC zone, or in a charter park, are subject to the following design guidelines, in addition to the general guidelines set forth above: (1) To the greatest extent possible, the City prefers that new utility poles for small wireless facilities be constructed in alleys. However, upon a demonstration of need related to the provision of wireless services by the wireless provider, introduction of pedestrian level light poles which augment district design characteristics and accommodate small wireless facilities may be considered within the right-of-way and at intersections. (2) The POD may consider the granting of a waiver to the height restrictions of this section in an effort to accommodate the placement of a small wireless facility, including a new utility pole, in an alley. (3) Any request by an applicant to construct a new utility pole in City right-of-way that is not an alley may be subject to the alternative location negotiation procedure, in accordance with Section 25-308(c)(3) of the City Code. (c) Placement within a scenic/non-commercial corridor. Unless otherwise authorized by a franchise agreement, for public safety purposes, or waived in accordance with subsection (d) below, no net new utility poles shall be placed within a designated scenic/non-commercial corridor. (d) Waiver of design standards. The design standards may be waived by the POD if a particular standard is either not reasonably compatible to a particular location or imposes an excessive expense.
(Ord. No. 317-H, § 4, 12-14-2017)
Ask a question about St. Petersburg law
Corpus searches the St. Petersburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.
