Sec. 10-282.2. - Provisions for Design Review Districts: All Saints Neighborhood (Shown on DT-1), Florida State University Transition Area (Shown on DT-1), and University Village (Shown on DT-5).
(a) Purpose and intent. The design review districts promote the conservation, enhancement, and continued vitality of areas of the city with special scenic, architectural, or cultural value, or neighborhood character through review by the planning department. Design review ensures that certain types of infill development will be compatible with the neighborhood and enhance the area. The planning department shall review all development plans within the University Village (UV) and ASN All Saints Neighborhood districts, as delineated on maps DT-1 and DT-5, and the FSU Transition Area, which is that area bounded on the north by Tennessee Street, on the east by Macomb Street, on the west by Copeland Street, and on the south by Madison Street, and as shown on DT-1. The Design Review Districts are envisioned as vibrant in-town neighborhoods that integrate a broad mix of residential and commercial development. The intent of the design review is to implement this vision by facilitating the specific character and type of development that the Gaines Street Revitalization Plan encourages for the corridor and the adjacent All Saints Neighborhood. For the Florida State University Transition area, development shall be facilitated that harmonizes with and complements buildings on the campus and the character of the neighborhood itself. This section establishes criteria to guide future development activities in these districts. (b) General principles. The standards and guidelines for the Design Review Districts are intended to encourage flexibility and variety in development through good site and building design, defined in terms of the following principles which shall be applied by the designers and considered by the planning department and plan reviewers through the development approval process: (1) Sense of place. All development shall contribute to making the district a distinct and memorable part of the city, unique in spaces, buildings, and street character. (2) The public realm. All development shall be oriented and designed to contribute to the street environment intended for each district and shall place priority on pedestrian comfort, convenience, safety, and access. (3) Human scale. Human or pedestrian scale and human scale elements refer to buildings and spaces whose dimensions, properties, and components correspond to human occupation and use. Examples include individual, operable windows, seating, and shaded sidewalks. (4) Neighborhood fit. All development shall be sited and designed to complement and harmonize with existing or intended neighborhood development patterns, particularly with reference to building scale and orientation. (5) Site access. Access to all development shall be sited and designed to have a positive visual impact on the street, and shall provide primary pedestrian access to the public street. Driveways and parking shall not have primacy over pedestrian areas. (6) Visual interest. Variety in design elements, transparency, color, texture, signs, and materials creates a visually interesting environment and contributes to the establishment of an architectural character for the neighborhood. (7) Compatibility. Defined as the condition in which land uses or conditions can coexist in relative proximity to each other, in a stable fashion over time, such that no use or condition is negatively or indirectly impacted by another use or condition. Architectural compatibility is necessary to visually integrate a mix of uses and building types. All development shall be designed to have an architectural composition of forms that relate well in proportion, scale, geometry, and materials, both to one another and to its context. Architectural compatibility is not limited to any particular style, and contemporary architecture that complies with the design standards and guidelines of each district is encouraged. (c) Development and design standards applicable to all properties. These development and design standards are subject to review and final action by the planning department. (1) Site planning. a. Development pattern. A predominant building type, size of lots, siting of the building on the lot, lot coverage, and relationship of the building to the street determine a development pattern. New development must be harmonious with the predominant development pattern of the district. b. Street character. Development consistency in the following qualities lends character and a sense of place to a street: 1. Types of uses and their relationship with the street, and the liveliness they contribute to the street. A street of ground floor shops and restaurants will have a character different from that of a street of residences. 2. The degree of enclosure formed by the distance between buildings, across the street, their height, and the openness of spaces between buildings. 3. The extent of the public realm of the street as defined by progressions from public to private space; there is a discernible and intentional difference between the public places on the street and the private spaces attributable to residences and businesses. 4. Rhythm established by a predominate repetition of buildings and open spaces, or by a pattern of openings in facades. 5. The contribution of building and landscape design to the ensemble of buildings on the street. 6. Human scale as expressed in building size, height, massing, transparency, and detail. (2) Building orientation. a. All buildings shall be located and designed to be compatible with the predominant development pattern. b. Primary entrances shall face the street. At least one public entrance of each principal structure shall be oriented toward the front lot line or street side lot line. Developments are encouraged to provide as many pedestrian connections to the street as feasible. c. On corner lots, new buildings shall be oriented toward the streets and shall consider and complement the pattern of existing adjoining development, with the primary facade(s) of the building facing the front lot line and/or the street side lot line. d. Corner locations shall be considered opportunities for distinctive architecture. e. Accessory structures, if any, shall be located at rear of principal buildings. (3) Site and building access. a. Whenever feasible, driveway access to a site shall be shared with adjacent properties and parking shall be located internally to the block or at the rear of the site, except where existing garages associated with detached single family residences or duplexes may be accessed from the street. b. Service areas associated with multiple family dwellings shall be accessed from the rear of the site wherever feasible. (4) Parking and parking garages. a. Automobile and bicycle parking spaces for each land use shall be provided in accordance with standards in Section 10-285, Tables 8B and 8C. b. Minimum setbacks for front, side, and rear yards shall apply to parking structures and to parking lots, including associated pedestrian accessways adjacent to non-parking structures. c. With the exception of off-street parking associated with detached single-family residences or duplexes, all parking areas shall be configured so as to provide adequate maneuvering room and avoid backing motor vehicles directly onto the public street. d. All garages or carports shall be set back from the front facade. (5) Service areas. a. Screening: Service areas shall be screened from public view on all sides with the exception of the vehicle use area by structures, opaque fences, walls, or hedges to a minimum height one foot above the solid waste container or other service container or receptacle. This requirement does not preclude the gating of service areas as a preference of the developer as long as the gate is directed to the service vehicle area. Screening materials can include those identified in Section 10-411(b)3 and the use of chain link, plastic or vinyl fencing as screening materials is prohibited. b. General Provisions for access, operation and placement of services: (1) Miscellaneous Services Areas: Areas used for primary circulation and for frequent idling of vehicle engines shall be designed and located to minimize impacts on adjoining properties, and shall include provisions for screening or buffering as listed in (5)(a). (2) Solid Waste Service Areas: (a) Dumpsters and permanently placed refuse receptacles shall be located a minimum of 20 feet from adjacent residential uses, where practical and feasible, and sufficiently screened from public rights of way. To minimize clutter, joint use of waste receptacles within one or more development projects under common management or ownership is required, and between two or more developments not under common management or ownership, where feasible, is strongly encouraged. (b) Rollout waste receptacles are permitted. Rollout waste receptacles are required to be stored in screened service areas. (c) Use of shared waste collection sites, owned and maintained by the city, may be required. In addition to the above requirements, the following requirements shall apply to shared collection sites: (i) Dimensions including turning radii, openings, gates, and pull-throughs, shall be those required by the city solid waste division. (ii) Driveways between the curb and the structure at waste collection sites shall be paved with brick, stone, or concrete unit pavers, suitably reinforced. (3) Recycling Services: Each building shall dedicate a specific location for recycling separation, storage, and access. (6) Off-street loading. There is no required number of off-street loading spaces for uses. On-street loading zones may serve all land uses. The off-street loading space standards in section 10-388 are not applicable in the design review districts. Areas used for loading activities shall be designed and located to minimize impacts on adjoining properties. (7) Landscape features. Driveway and walkway paving shall be unit pavers such as brick, stone, asphalt, or concrete pavers installed on a sand bed. Semi-pervious paving materials are encouraged. (8) Preservation of historic landscape features. Landscape features identified as "character defining features" of the All Saints Neighborhood, downtown, or the Gaines Street corridor, including existing historic structures, rubble retaining walls, patriarch trees, and historic parks, shall be preserved. (9) Building design standards. Individual building design shall defer to the ensemble of buildings on the street rather than call undue attention to itself. New buildings shall contribute to the life of the street, and share the following with existing buildings that exemplify the area's character. a. Architectural articulation. 1. A building's exterior walls shall be articulated using materials, architectural elements, arrangement of openings, design of horizontal and vertical planes, and changes in height to provide substantial massing variations. 2. Articulation, including but not limited to window casings, eaves, cornices, railings, foundation walls, shutters, downspouts, fascias, gables, and gutters, shall complement the architecture of adjacent buildings while providing variety among building masses and facades of buildings on a street. Eaves, porch and arcade columns, roofs, railings, chimneys, etc. shall be detailed so as to emphasize these architectural features, consistent with the building's architecture. 3. Long, monotonous roof planes and uninterrupted expanses of blank wall are not allowed along street frontages. Articulated roof forms and wall openings shall be used to add visual interest and contribute to a human scale. 4. Buildings greater than two stories in height shall delineate clearly the boundary between each floor of the structure with belt courses, material changes, a band of signage (if applicable), or other architectural detailing. Attached buildings in the same block shall maintain consistent cornice lines, plus or minus five (5) feet. 5. Doorways, windows, storefronts, and other openings in the facades of buildings shall be placed and proportioned to reflect pedestrian scale and movement, and to encourage visual interest at the street level. The use of functional and decorative elements, including weather protection features (i.e., colonnades, arcades, canopies, etc.), signage, and architectural detailing, shall be used to create human scale on a building's principal facade. Elements shall be integral to the architecture of the building, designed so as to not appear to be "tacked on" to the building facade. 6. Doors and windows shall be compatible with the composition and architectural style of the building. 7. On any building, a consistent rhythm of openings shall be maintained above street level on all facades facing a street. Openings need not be identical from building to building; small variations from facade to facade will provide visual interest. 8. Where solid walls are required by building code, the wall shall be articulated and divided into distinct modules, through the use of projections and recesses (e.g., setbacks, reveals, belt-courses, awning, arcades, porches, etc.) within the building envelope or projecting from upper floors. 9. Functional balconies. Balconies must be useable and accessible through operable full height doors. Balconies must be a minimum of six (6) feet deep. 10. Commercial buildings and buildings with ground floor commercial uses shall have a ceiling height minimum of twelve (12) feet for the ground floor. b. Prohibited Materials and Design Features. 1. Inoperable or fixed shutters. 2. Reflective glass or tinted glass at the first and second story with less than 70 percent light transmission. (10) Transparency. Building facades along public rights of way shall have non-reflective, transparent areas covering: a. Mixed-use/Non-residential uses: A minimum of 70 percent of the first floor facade surface area at pedestrian eye level (between three (3) feet and eight (8) feet above grade), or b. Residential uses (single-family detached units exempt): A minimum of 50 percent of the first floor facade surface area at pedestrian eye level (between three feet and eight feet above grade), and c. A minimum of 15 percent transparency above the first story. d. The area of entrance doors and each facade shall be calculated separately. (11) Materials and colors. a. To avoid monotonous wall surfaces, all buildings shall use materials that offer texture, including wood, pantile, brick, or stone or high-quality synthetic materials. Materials shall be used consistently on all sides of a structure. b. Color shall be an integral element in the design of all structures. A coordinated palette of colors shall be created for each project or development. This palette shall be compatible with those of adjacent developments. c. The use of natural and natural-looking roof materials is strongly encouraged, particularly those that contribute texture, pattern, and color. Acceptable roof materials include standing-seam metal, textured shingles, pantile, and slate. High-quality dimensional asphalt shingles are acceptable. d. Color variation shall be used to break up the mass of a building and to provide interest. However, the number of color choices in any given building shall be limited to a wall color, roof color, trim color, and accent color. (12) Design features for parking structures. a. Accessory parking structures if any shall be located to the rear of the building and accessed from the rear or side of the lot. b. The ground floor of a parking structure that is the principal use on a site shall be occupied by non-residential uses. c. Design standards for parking structures shall also apply to parking located on the ground floor of a building. d. Maximum building height for the district is applicable to parking structures. All exterior facades of parking structures shall comply with design standards for massing and density, facade articulation, and materials established for other building types. e. The size and proportions of openings in parking structures shall be compatible with neighboring buildings. Openings in parking structures shall be screened so that no cars, headlights, or light fixtures are visible from the surrounding streets and uses. Glazing, perforated metal panels, applied surface elements, landscaping, or combinations of these materials, and materials from adjacent buildings, may be used on the facade to screen openings. f. Driveway and pedestrian entries of parking structures shall be integrated with the ground level facade. g. Ground floor ceiling height for retail or commercial uses in parking structures along the public street frontage shall be at least twelve (12) feet. (13) Streetscape standards. a. All areas shall be connected by sidewalks. b. All sidewalks in nonresidential areas and mixed-use areas shall provide a continuous, unobstructed clear width area of no less than six (6) feet. c. Street furniture and street lighting shall be required to be in conformance with a comprehensive streetscape program that establishes a uniform theme for each area where such streetscape is intended. d. Street lighting shall be installed on both sides of the street a maximum of 100 feet apart. The general preference shall be for smaller, but more frequent light fixtures rather than fewer high-intensity lights. All fixtures shall use a metal halide light source. Sodium vapor and similar types of light sources are prohibited. All fixtures, whether wall mounted or freestanding, shall be total cutoff and directed downward to reduce glare on adjacent properties. e. Utility service lines shall be provided underground or run through the rear alleyways. Electric meters, antennas, and exterior storage areas shall be screened from public view in a manner compatible with the principal structures and site design. The use of dense landscape plantings for screening is encouraged, appropriate to the district. f. Solid waste, recycling, and yard trash containers (except public litter containers); grease containers; and loading docks shall be located in parking areas or other locations remote from the sidewalk. g. All outdoor mechanical equipment, including heating, air conditioning, and ventilation systems, shall be placed on the roof, to the rear or side of a building, or be otherwise visually screened from the street. In no case shall mechanical equipment be allowed along the street frontage. Mechanical equipment on the roof shall be screened from abutting streets with parapets or other types of visual screening. h. Standpipes or hose bibs are required for cleaning purpose at all commercial street fronts and at all waste collection locations. (14) Energy conservation. Building design shall use energy conservation measures including but not limited to self-shading, natural lighting, natural ventilation, outdoor circulation, and reduced dependence on artificial lighting and air conditioning.
(Ord. No. 13-O-03, § 14, 8-28-2013; Ord. No. 15-O-04, § 12, 5-27-2015)