§ 10-282.3 — Specific to University Village (Map DT-5. Downtown West)
Code of General Ordinances of the City of Tallahassee, Florida (Supp. No. 75: codified through Ordinance No. 25-O-28, enacted December 10, 2025) · Tallahassee Land Development Code § 10-282.3
Corpus is an independent public-information project, not the official City of Tallahassee website. Stable reference: corpuslaw.us/code/1cf6456d-064c-455d-bd08-7a2e26f7ea03
Sec. 10-282.3. - Specific to University Village (Map DT-5. Downtown West).
(a) Streetscape along Gaines Street and Railroad Avenue. (1) Planting areas between arcade columns and openings, and vine planting areas at the face of the buildings, are encouraged. (2) Along Gaines Street from its intersection with Martin Luther King Jr. Boulevard in the east to Lake Bradford Road in the west, development shall provide setbacks to accommodate infrastructure, as required here: a. A minimum 13-foot setback from the back of curb to the face of the building for appropriate sidewalk width; and b. Development is permitted an additional maximum 10-foot setback from the edge of the sidewalk, resulting in 23 feet of hardscape between the curb and face of the structure. c. When located on private property, the sidewalk shall be placed in easement to maintain public access. d. While sidewalk activity is encouraged, a minimum 6-foot clear zone shall be maintained for pedestrian passage. (b) Pedestrian connectivity. (1) Publicly accessible pedestrian passageways from the street to and through the interior of the block are encouraged to separate pedestrians from traffic and provide pedestrian access from parking lots at the rear of buildings to the street. Passageways shall be a minimum of eight (8) feet wide and a minimum of twelve (12) feet high. Upper floors are encouraged to continue over the passageway. Pedestrian passageways shall be designed to preclude normal vehicular access and preferably be separate from other emergency vehicle access ways to the interior of the block. (2) Driveways to Gaines Street and Railroad Avenue are discouraged. (c) Design Features for New Buildings. (1) Retail and office building walls along sidewalks shall have non-reflective, transparent areas covering at least seventy-five 75 percent of the first floor facade surface area at pedestrian eye level (between three feet and eight feet above grade). All glazing shall be of a type that permits view of human activities and spaces within. Enclosed security areas, if any, shall be of the mesh type that pedestrians can see through and shall be located behind storefront displays. The area of operable entrance doors and each facade shall be calculated separately. (2) Facades with an emphasis on vertical proportions shall be employed to break up continuous building frontages and maintain compatibility with the scale of the historical building pattern of the adjacent buildings. Facade modules shall be no less than twenty (20) feet and no more than thirty-five (35) feet in width. (3) Articulation of building facades should establish a rhythm of vertical modules unified by a complementary rhythm of upper floor windows. Upper floor windows of adjacent buildings need not be identical in design or spacing. (d) Colonnades and arcades. (1) Where a colonnade or arcade is structurally integrated into the facade, the upper floors of the building may be either flush with the setback or be stepped back to a maximum setback of 12 feet from the face of the colonnade or arcade. (2) Colonnades and arcades shall have a 12-foot minimum depth. Depth shall not exceed height of openings to the street. Design standards for transparency established for other storefronts shall apply to interior walls of colonnades and arcades. (3) The spacing of columns or piers, measured from the centerline of the columns or piers, shall not be greater than the height of the colonnade or arcade. The height of the colonnade or arcade shall be the vertical distance measured from the finished floor to the ceiling of the colonnade or arcade. (e) Prohibited Materials. (1) Exterior insulation and finish systems (EIFS), also known as synthetic stucco and sheet metal; (f) Mixed-use developments. A mix of uses within a single project or structure is encouraged. The following design features are required for vertical mixed-use projects, in which different uses are located on different floors of a single structure: (1) Non-residential, commercial uses are required on the ground floor of a vertical mixed-use project. Residential uses are prohibited from being located on a floor below a commercial use in a vertical mixed use project with the exception of lobbies and common circulation areas, which may be located above the ground floor. The intensity of the uses should decrease as the floors go up. (2) Residential uses that are part of a vertical mixed-use project shall be permitted as-of-right, provided the project otherwise meets the conditions of (f)(1), above.
(Ord. No. 13-O-03, § 14, 8-28-2013)
Ask a question about Tallahassee law
Corpus searches the Tallahassee sections it holds and shows the ones that match, with their citations. Free, no sign-in.
