For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10-411 — Accessory structures

Code of General Ordinances of the City of Tallahassee, Florida (Supp. No. 75: codified through Ordinance No. 25-O-28, enacted December 10, 2025) · Tallahassee Land Development Code § 10-411

Corpus is an independent public-information project, not the official City of Tallahassee website. Stable reference: corpuslaw.us/code/6adf1795-8f71-433b-8230-854b9a258ab0

Sec. 10-411. - Accessory structures.

(a) General requirements. It is the purpose of this section to regulate the installation, configuration, and use of accessory structures, and the conduct of accessory uses, in order to ensure that they are not harmful either aesthetically or physically to residents and surrounding areas. Any number of different accessory structures may be located on a parcel, provided that the following requirements are met: (1) There shall be a permitted principal development on the parcel, located in full compliance with all standards and requirements of this chapter. (2) All accessory structures shall setback ten feet from any property line, except where the permitted principal development setback is less in which case the accessory structure shall comply with the principal structure setback. (3) Accessory structures shall not be located in a required buffer or landscape area nor in the front yard or side corner yard. (4) Accessory structures shall be included in all calculations of impervious surface and stormwater runoff. Water surface area of a pool will not be considered part of impervious surface for stormwater calculations. (5) Accessory structures shall be shown on any concept development plan with full supporting documentation as required in chapter 9, article III of this Code. (6) Accessory structures shall be located at least six feet from any other structure on the same lot. (b) Storage buildings, utility buildings, equipment, and infrastructure. (1) No accessory buildings used for industrial storage of hazardous, incendiary, noxious or deadly materials shall be located nearer than 100 feet from any property line. (2) Vehicles, including travel trailers, recreational vehicles, manufactured housing and mobile homes/manufactured homes, shall not be used as storage buildings, utility buildings or other such uses. (3) Utilities, equipment, and infrastructure. a. New development. No exterior utility accessories used for service loading entries, parking for commercial vehicles with cargo volumes greater than ten cubic yards (referred to below as "loading zones"), solid waste facilities with capacities greater than one cubic yard (referred to below as "trash enclosures"), nonresidential air conditioning compressors greater than ten tons, air compressors, electrical generators, or overhead electrical transformers shall be located nearer than ten feet from any property line or 200 feet from any property line adjoining a low-density residential zoning district. b. Lot configuration does not permit attainment of 200-foot buffer. For the purposes of subsection (b)(3)b. and e., the term "protected residential" includes any property that is zoned either RP-1, RP-2, RP-MH, RP-R, RP-UF, R-1, R-2, R-3, R-5, UF, LP, MH, or RA. 1. Loading zone. If the distance between the back of a building and the rear property line is less than 220 feet, then the project may locate the loading zone to within 50 feet of the boundary of the adjoining property which is protected residential provided it is buffered from the property which is protected residential with a minimum of a ten-foot wide landscape strip along its full length between the loading zone and the nearest protected residential. The landscape strip must include at least two trees from the list at section 10-285, table 4. 2. Trash enclosure. If the distance between the back of a building and the rear property line is less than 220 feet, then the project may locate the trash enclosure to within 50 feet of the boundary of the adjoining property which is protected residential provided it is buffered from the property which is protected residential by a six-foot opaque wall of finished masonry or wood on three sides, with a gated door accessible to service vehicles. If a wall of a trash enclosure is generally parallel to protected residential, then a ten-foot wide landscape strip shall be adjacent to the trash enclosure along the full width of the side(s) facing the property which is protected residential. If a corner of a trash enclosure is adjacent to protected residential, then the ten-foot wide landscape strip shall be adjacent to one of the trash enclosure walls that form that corner. The landscape strip must include at least one tree from the list at section 10-285, table 4. 3. Lots with multiple frontages. For sites with multiple street frontages, the front yard is the principal frontage as defined by section 1-2. Loading zones and trash enclosures shall be sited in the rear yard of such properties. If the distance between the back of a building and the rear property line is less than 220 feet, then the loading zone or trash enclosure shall meet the following criteria: A. Be a minimum of 50 feet from any property boundary that is adjacent to protected residential; B. be a minimum of 50 feet from any property boundary that is across a street from protected residential, provided the street has three or fewer travel lanes (including on street parking, merge, and turn lanes); and C. Provide the buffer wall or fence, landscaping, and trees noted in subsection (b)(3)b. c. Redevelopment. Redevelopment projects that propose a solid waste facility with a capacity greater than one cubic yard that is enclosed with a six-foot opaque wall of finished masonry, wood, or natural plant material on three sides, with a gated door accessible to service vehicles, are not required to comply with the ten-foot or 200-foot setbacks set forth in this section. Solid waste facilities for redevelopment projects are required to be located behind buildings or other structures so as to screen them from public rights-of-way. d. Earthwork disturbances. No earthwork disturbances for stormwater swales, detention ponds or retention ponds shall be located nearer than 30 feet from any (existing) property line adjoining a low-density residential zoning district. This does not include earthwork disturbances for underground stormwater facilities, stormwater swales centered on (proposed) property lines with a common utility easement, or perpendicular crossings of property lines by stormwater swales. Redevelopment projects are exempt from complying with the 30-foot distance requirement set forth in this subsection (b)(3)d. for earthwork disturbances associated with stormwater swales. Earthwork disturbances associated with stormwater retention or detention ponds for redevelopment projects must comply with a 15-foot distance requirement from any (existing) property line adjoining a low-density residential zoning district. e. Subsection (b)(3) does not apply to the following: 1. Proposed non-residential or dense residential developments adjacent to properties which are Protected Residential that are currently developed and occupied by a legally existing non-conforming use; or 2. Proposed non-residential or dense residential developments adjacent to isolated properties which are protected residential comprised of less than three units on less than three contiguous lots. For purposes of this section, "isolated" shall mean one or two residential units, which are surrounded by non-residential zoning or uses. 3. A change of use at an existing non-residential or dense residential development, provided the change of use does not result in a more intense use that is otherwise regulated by subsection 10-411(b)(3). (c) Swimming pools, hot tubs and similar structures. (1) Swimming pools shall be permitted only in side and rear yards, and shall not encroach into any required building setback. (2) Enclosures for pools shall comply with standards for yard requirements and other building location requirements of this chapter. (3) All pools shall be completely enclosed with an approved wall, fence or other substantial structure not less than four feet in height. The enclosure shall completely surround the pool and shall be of sufficient material to prohibit unrestrained admittance to the enclosed area through the use of self-closing and self-latching doors.

(Code 1984, ch. 27, § 17.1; Ord. No. 95-O-0025AA, 9-13-1995; Ord. No. 97-O-0027AA, § 48, 7-8-1997; Ord. No. 99-O-0058AA, § 9, 1-26-2000; Ord. No. 01-O-28AA, §§ 34—36, 10-24-2001; Ord. No. 21-O-15, § 4, 6-16-2021)

Ask a question about Tallahassee law

Corpus searches the Tallahassee sections it holds and shows the ones that match, with their citations. Free, no sign-in.