Sec. 6-61. - General standards.
In all areas of special flood hazard, the following provisions are required: (1) New construction and substantial improvements shall be anchored to prevent flotation, collapse, and lateral movement of the structure; (2) Manufactured homes and mobile homes shall be anchored to prevent flotation, collapse, and lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable state requirements for resisting wind forces; (3) New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage; (4) New construction and substantial improvements shall be constructed by methods or practices that minimize flood damage; (5) Electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; (6) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system; (7) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters; (8) On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding; and (9) Any alteration, repair, reconstruction, or improvement to a structure, which is in compliance with the current provisions of this chapter, shall meet the requirements of new construction as contained in this chapter. (10) Any existing structure built in conformance with the flood damage protection regulations at the time of its construction shall be deemed in compliance with these regulations. Any repairs, renovations or additions to existing structures shall be required to meet the requirements in effect at the time of the original construction unless said repairs, renovations or additions meet the definition of substantial improvements as defined in this chapter. (11) Standards for subdivision proposals. The director shall review all subdivision proposals and other proposed new developments in the special flood hazard areas to ensure that: (i) All subdivision proposals shall be consistent with the need to minimize flood damage; (ii) All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical, and water systems located and constructed to minimize flood damage; (iii) All subdivision proposals shall have adequate drainage provided to reduce exposure to flood hazards; and (iv) Base flood elevation data shall be provided for subdivision proposals and other developments (including manufactured home parks and subdivisions) which are greater than the lesser of 50 lots or five acres. (12) The director shall review proposed development to assure that all necessary permits have been received from those governmental agencies from which approval is required by federal or state law, including section 404 of the Federal Water Pollution Control Act Amendments of 1972, 33 U.S.C. 1334.
(Code 1984, § 7-265(a); Ord. No. 01-O-78AA, § 1(7-265(a)), 12-12-2001; Ord. No. 04-O-103, § 1, 12-15-2004; Ord. No. 09-O-48, § 3, 10-28-2009)
Ask a question about Tallahassee law
Corpus searches the Tallahassee sections it holds and shows the ones that match, with their citations. Free, no sign-in.