Sec. 6-62. - Specific standards.

In all areas of special flood hazard where base flood elevation data have been provided, as set forth in section 6-11 or subsection 6-31(b)(7), the following provisions are required: (1) Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated no lower than two feet above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with standards of subsection (3) of this section. All manufactured homes to be placed or substantially improved within zones A1—30, AH, and AE shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is at least two feet above the base flood elevation and is securely anchored to an adequately anchored foundation system in accordance with the provisions of subsection 6-61(2). All equipment or mechanical items for new construction, and any substantial improvement of any residential structure or manufactured home, shall be at an elevation of at least one foot above the base flood elevation. (2) Nonresidential construction. New construction and substantial improvement of any commercial, industrial, or other nonresidential structure shall have the lowest floor, including basement, elevated no lower than two feet above the level of the base flood elevation. Structures located in all A zones may be floodproofed in lieu of being elevated provided that all areas of the structure below the required elevation are watertight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. Such certification shall be provided to the official as set forth in subsection 6-32(b). (3) Enclosures below lowest floor. New construction and substantial improvements of elevated buildings that include fully enclosed areas formed by foundation and other exterior walls below the base flood elevation shall be designed to preclude finished living space and designed to allow for the entry and exit of floodwaters to automatically equalize hydrostatic flood forces on exterior walls. a. Designs for complying with this requirement must either be certified by a professional engineer or architect or meet or exceed the following minimum criteria: 1. Provide a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; 2. The bottom of all openings shall be no higher than one foot above grade; and 3. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided they permit the automatic flow of floodwaters in both directions. b. Electrical, plumbing, and other utility connections are prohibited below the base flood elevation; c. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator); and d. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. (4) Encroachments into areas with base flood elevation, but without regulated floodways. a. No encroachments, including new construction, substantial improvements, or other developments (including fill) shall be permitted unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one foot at any point within the community. b. Notwithstanding any other provisions of this chapter, the city may approve certain development in Zones Al-30, AE, and AH, on the community's FIRM which increase the water surface elevation of the base flood by more than one foot, provided that the city first applies for a conditional FIRM revision, fulfills the requirements for such a revision as established under the appropriate provisions of the Code of Federal Regulations, and receives the approval of the Federal Insurance Administrator. (5) Floodways. Located within areas of special flood hazard established in section 6-11 are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles and has erosion potential, the following provisions shall apply: a. Prohibit encroachments, including fill, new construction, substantial improvements, and other developments unless certification (with supporting technical data) by a registered engineer is provided demonstrating that encroachments shall not result in any increase in flood levels during occurrence of the base flood discharge; and b. If subsection (5)a. of this section is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of this article. c. Notwithstanding any other provisions of this chapter, the city may permit encroachments within the adopted regulated floodway that would result in an increase in base flood elevations, provided that the city first applies for a conditional flood insurance rate map (FIRM) and floodway revision, fulfills the requirements for such revisions as established under the appropriate provisions of the Code of Federal Regulations, and receives the approval of the Federal Insurance Administrator.

(Code 1984, § 7-265(b); Ord. No. 01-O-78AA, § 1(7-265(b)), 12-12-2001; Ord. No. 09-O-48, § 3, 10-28-2009; Ord. No. 20-O-46, § 1, 1-27-2021)

Ask a question about Tallahassee law

Corpus searches the Tallahassee sections it holds and shows the ones that match, with their citations. Free, no sign-in.