§ 2.7 — Building Types
Code of Ordinances of the City of Alpharetta, Georgia (Codified through Ordinance No. 908, enacted August 2, 2026 (Supp. No. 16, Update 1)) · Alpharetta Unified Development Code, App. A, art. 2, § 2.7
Corpus is an independent public-information project, not the official City of Alpharetta website. Stable reference: corpuslaw.us/code/f286fb32-7ad4-4387-bf1f-970cd22dee9d
Sec. 2.7. - Building Types.
The following rules apply to all buildings in the Downtown Overlay. 2.7.1. Descriptions. Within the Downtown Overlay building types are used to regulate the design of buildings. Each building type is described below. A building's building type is determined by the Director of Community Development. Within Downtown Zoning District, building types are subject to the additional use requirements of the applicable zoning district. All graphic depictions of building types are for illustrative purposes only. Note that these building types are for zoning purposes only, and not linked to the Building Code. Freestanding parking structures are not considered to be a building type. [image omitted; see the official code] A. Detached House. A building type that accommodates one dwelling unit on an individual lot with yards on all sides. Not intended for nonresidential uses. [image omitted; see the official code] B. Carriage House. A small self-contained accessory dwelling unit located on the same lot as a detached house, semi-detached house, or townhouse but physically separated, for use as a complete, independent living facility, with provisions for cooking, sanitation and sleeping. [image omitted; see the official code] C. Cottage Court. A building type designed to accommodate 5 to 10 detached dwelling units organized around a shared internal courtyard. Units cannot be vertically mixed. [image omitted; see the official code] D. Semi-Detached House. A building type that accommodates two dwelling units arranged either horizontally or vertically. Not intended for nonresidential uses. [image omitted; see the official code] E. Townhouse. A building type that accommodates 3 or more dwelling units where each unit is separated by a common side wall. Units cannot be vertically mixed. [image omitted; see the official code] F. Walk-up Flat. A building type that accommodates 3 to 8 dwelling units vertically and horizontally integrated. [image omitted; see the official code] G. Stacked Flat. A building type that accommodates 9 or more dwelling units vertically and horizontally integrated. [image omitted; see the official code] H. Commercial House. A building type that accommodates nonresidential uses in a building type that resembles a detached house. Not intended for residential uses. [image omitted; see the official code] I. Shopfront. A single-story building type that typically accommodates single-use retail or commercial activity. [image omitted; see the official code] J. Mixed Use Building. A multi-story building type that typically accommodates ground story retail, office, or commercial uses with upper-story residential or office uses. Not for ground story street-facing residential uses along arterial or collector streets. [image omitted; see the official code] K. General Building. A multi-story building type that typically accommodates nonresidential uses such as industrial, hotel, or office uses on all stories. [image omitted; see the official code] L. Civic Building. A building type that accommodates civic uses. Not intended for commercial, retail, office, or residential uses. 2.7.2. Rules Specific to Building Types. A. Detached House. A building type that accommodates one dwelling unit on an individual lot with yards on all sides. Not intended for nonresidential uses. [image omitted; see the official code] Lot Detached house units per lot: | 1 max. Pedestrian Access Entrance facing street: | Required Walkway width: | 3 ft min./5 ft max. B. Carriage House. A small self-contained accessory dwelling unit located on the same lot as a detached house, semi-detached house, or townhouse but physically separated, for use as a complete, independent living facility, with provisions for cooking, sanitation and sleeping. [image omitted; see the official code] Lot > Carriage house units per lot: | 1 max. Size Dwelling Floor Area: | 700 sf max. (excluding garage) Bedrooms: | 1 max. Pedestrian Access Entrance facing street: | Not Required Walkway width: | n/a C. Cottage Court. A building type designed to accommodate 5 to 10 detached dwelling units organized around a shared internal courtyard. Units cannot be vertically mixed. [image omitted; see the official code] Site Site width/depth: | 150 ft min. Cottage court units per site: | 5 min./10 max. Courtyard Area: | 3,000 sf min. Width: | 40 ft min. Courtyard may not be parked or driven upon, except for emergency access and permitted temporary events. Pedestrian Access Entrance facing street: | Required for units along street Walkway width: | 3 ft min./5 ft max. D. Semi-Detached House. A building type that accommodates two dwelling units arranged either horizontally or vertically. Not intended for nonresidential uses. [image omitted; see the official code] Lot Semi-detached house units per lot: | 2 max. Pedestrian Access Entrance facing street: | Required Walkway width: | 3 ft min./5 ft max. E. Townhouse. A building type that accommodates 3 or more dwelling units where each unit is separated by a common side wall. Units cannot be vertically mixed. Not intended for nonresidential uses. [image omitted; see the official code] Site Townhouse units per site: | 3 min. Townhouse units in a row: | 8 max. Fenestration Ground floor: | 15% min. Upper story: | 15% min./35% max. Blank wall area: | 20 ft max. (per story) Pedestrian Access Entrance facing street: | Required for units along street Walkway width: | 3 ft min./5 ft max. Parking Location No on-site parking is allowed between the building and the street. Design No more than three adjacent units may have identical facade designs. Differentiation between adjacent units may be accomplished by a change in materials, building height, color, roof form, or setbacks. F. Walk-up Flat. A building type that accommodates 3 to 8 dwelling units vertically and horizontally integrated. [image omitted; see the official code] Site Walk-up flat units per building: | 3 min./8 max. Fenestration Ground floor: | 20% min. Upper story: | 20% min./40% max. Blank wall area: | 20 ft max. (per story) Pedestrian Access Entrance facing street: | Required for lobby (if provided) or ground floor units along street (if no lobby) Walkway width: | 3 ft min./6 ft max. Parking Location No on-site parking is allowed between the building and the street. G. Stacked Flat. A building type that accommodates 9 or more dwelling units vertically and horizontally integrated. Intended for primarily residential uses, but may include limited ground story. [image omitted; see the official code] Site Stacked flat units per building: | 9 min. Street facing façade length: | 200 ft max. Fenestration Ground floor: | 20% min. Upper story: | 20% min. / 40% max. Blank wall area: | 20 ft max. (per story) Pedestrian Access Entrance facing street: | Required for lobby and ground floor units along street Walkway width: | 3 ft min. /8 ft max. Parking Location No on-site parking is allowed between the building and the street. H. Commercial House. A building type that accommodates nonresidential uses in a building type that resembles a detached house. Not intended for residential uses. [image omitted; see the official code] Site Street facing façade length: | 100 ft max. Fenestration Ground floor: | 15% min. / 30% max. Upper story: | 15% min. / 30% max. Blank wall area: | 20 ft max. (per story) Pedestrian Access Entrance facing street: | Required for businesses facing street Walkway width: | 6 ft min. Parking Location No on-site parking is allowed between the building and the street. I. Shopfront. A single-story building type that typically accommodates single-use retail or commercial activity. [image omitted; see the official code] Site Street facing façade length: | 200 ft max. Height Ground floor height (floor to ceiling): | 14 ft min. Fenestration Ground floor: arterial or collector/local street: | 70% min./30% min. Blank wall area: arterial or collector/local street: | 30 ft max./50 ft max. Pedestrian Access Entrance facing street: | Required every 75 ft of frontage Walkway width: | 6 ft min. Parking Location No on-site parking is allowed between the building and the street. J. Mixed Use Building. A multi-story building type that typically accommodates ground story retail, office or commercial uses with upper-story residential or office uses. Not intended for ground story, street-facing residential uses along arterial or collector streets. [image omitted; see the official code] Site Street facing façade length: | 200 ft max. Height Ground floor height (floor to ceiling): | 14 ft min. Fenestration Ground floor: arterial or collector/local street: | 70% min./30% min. Blank wall area: arterial or collector/local street: | 30 ft max./50 ft max. Upper story: | 20% min./40% max. Pedestrian Access Entrance facing street: | Required every 75 ft of frontage Walkway width: | 6 ft min. Parking Location No on-site parking is allowed between the building and the street: K. General Building. A multi-story building type that typically accommodates nonresidential uses such as industrial, hotel, or office uses on all stories. [image omitted; see the official code] Site Street facing façade length: | 200 ft max. Height Ground floor height (floor to ceiling) : | 11 ft min. Fenestration Ground floor: arterial or collector/local street: | 50% min./20% min. Blank wall area: arterial or collector/local street: | 40 ft max. / 60 ft max. Upper story | 20% min. Pedestrian Access Entrance facing street: | Required every 150 ft of frontage Walkway width: | 6 ft min. Parking Location No on-site parking is allowed between the building and the street. L. Civic Building. A building type that accommodates civic uses. Not intended for commercial, retail, office, or residential uses. [image omitted; see the official code] Fenestration Ground floor: | 15% min. Blank wall area: | 60 ft max. Upper story: | 15% min. Pedestrian Access Entrance facing street: | Required Walkway width: | 6 ft min. Parking Location No on-site parking is allowed between the building and the street.
Ask a question about Alpharetta law
Corpus searches the Alpharetta sections it holds and shows the ones that match, with their citations. Free, no sign-in.