Sec. 2.8. - Building Design.
2.8.1. Applicable. This Section applies to the Building Types identified in Section 2.7. 2.8.2. Fenestration. A. Fenestration is the minimum percentage of window and door glass that must cover a facade. B. Glass used to satisfy fenestration requirements must be unpainted, must have a transparency (visible light transmission) higher than 70%, and must have an external reflectance of less than 15%. Transparency and external light reflectance must be established using the manufacturer's specifications. C. Fenestration is measured from the top of the finished floor to the top of the finished floor above. D. When there is no floor above, fenestration is measured from the top of the finished floor to the top of the wall plate. 2.8.3. Pedestrian Access. A. A pedestrian entrance and walkway providing both ingress and egress, operable to residents at all times and operable to customers, visitors, and employees during business hours, is required to meet the street-facing pedestrian entrance requirements. Additional entrances off another street, pedestrian area or internal parking area are permitted, but must have the same or shorter hours of operability as the street-facing entrance. B. An angled pedestrian entrance may be provided at either corner of a building along the street to meet the street-facing pedestrian entrance requirements. C. Where a lot has frontage on a civic space instead of a street, these requirement apply to and from the civic space. 2.8.4. Building Elements. A. Intent. The following standards are intended to ensure that certain building elements that when added to a street-facing facade are of sufficient size to be both usable and functional and be architecturally compatible with the building they are attached to. [image omitted; see the official code] B. Front Porch. A raised structure attached to a building, forming a covered pedestrian entrance to a doorway. 1. A front porch must be at least 6 feet deep (not including the steps). 2. A front porch must be contiguous, with a width not less than 33% of the building facade from which it projects. 3. A front porch must be roofed and may be screened, but cannot be fully enclosed. 4. A front porch may extend up to 9 feet, including the steps, into a required front setback, provided that such extension is at least 2 feet from the vertical plane of any lot line. 5. A front porch must not encroach into the public right-of-way or required sidewalk. 6. Steps leading to front porches must have enclosed risers. 7. Front porch columns must be a minimum width of 8 inches. [image omitted; see the official code] C. Stoop. A small raised platform that serves as a pedestrian entrance to a building. 1. A stoop must be no more than 6 feet deep (not including the steps). 2. A stoop may be covered but cannot be fully enclosed. 3. A stoop may extend up to 6 feet, including the steps, into a required setback, provided that such extension is at least 2 feet from the vertical plane of any lot line. 4. A stoop must not encroach into the public right-of-way or required sidewalk. 5. Steps leading to stoops must have enclosed risers. 6. Stoop columns, where provided, must be a minimum width of 8 inches. [image omitted; see the official code] D. Balcony. A platform projecting from the wall of an upper-story of a building with a railing along its outer edge, often with access from a door or window. 1. A balcony must be at least 4 feet deep and may extend up to 6 feet into a required setback, provided that such extension is at least 2 feet from the vertical plane of any lot line. 2. A balcony must have a clear height above the sidewalk of at least 10 feet. 3. A balcony may be covered and screened, but cannot be fully enclosed. 4. A balcony may encroach up to 6 feet into the public right-of-way or required sidewalk but must be at least 2 feet inside the curb line or edge of pavement, whichever is greater. [image omitted; see the official code] E. Awning/Canopy. A wall-mounted, cantilevered structure providing shade and cover from the weather for a sidewalk. 1. An awning must be a minimum of 10 feet clear height above the sidewalk and must have a minimum depth of 6 feet. 2. An awning may extend into a required setback. 3. An awning may encroach up to 9 feet into the public right-of-way or required sidewalk but must be at least 2 feet inside the curb line or edge of pavement, whichever is greater. 4. Awning must be made of canvas and may not be reflective or shiny. 5. Awnings must have open ends called "shed awnings" to allow views into buildings. 6. Awnings may not be internally lit. 7. Awnings may not be narrower than nor two feet wider than the door or window opening that they serve. Where multiple doors and windows are less than two feet apart, multiple awnings may be combined into a single awning. [image omitted; see the official code] F. Gallery. A covered passage extending along the outside wall of a building supported by arches or columns that is open on 3 sides. 1. A gallery must have a clear depth from the support columns to the building's facade of at least 8 feet and a clear height above the sidewalk of at least 10 feet. 2. A gallery must be contiguous and extend over at least 75% of the width of the building facade from which it projects. 3. A gallery may extend into a required setback. 4. A gallery may encroach up [to] 9 feet into the public right-of-way or required sidewalk but must be at least 2 feet inside the curb line or edge of pavement, whichever is greater. 2.8.5. General Architectural Standards. A. Applicability. 1. The following applies to all buildings, except as specifically stated otherwise. 2. Detached houses, carriages houses, cottage courts, semi-detached houses, townhouses, walk-up flats, and stacked flats must comply with either the following or Section 2.8.6, at the discretion of the applicant. 3. Commercial houses must comply with Section 2.9.6 [2.8.6]. B. Building Materials. 1. Exterior finish materials on walls visible from a street or civic space must be limited to brick, manufactured stone, architectural block, natural stone, wood siding, cement-based siding, cement-based panels, and/or hard coat stucco. 2. Hard coat stucco, when used as an exterior wall finish material on any individual building, is subject to the following additional standards: a. Hard coat stucco may not exceed 30% of the total wall area (excluding foundations) visible from a street or civic space. For the purpose of calculating conformance with this requirement, windows and doors are not included in the total wall area. b. The maximum wall length (excluding foundations) visible from a street or civic space that is finished in any continuous or discontinuous hard coat stucco is 60 feet. Authorized wall lengths finished in hard coat stucco must be separated by a minimum wall length of 60 feet that contains no hard coat stucco. [image omitted; see the official code] 3. Exterior finish materials must be combined only horizontally, with the visually heavier below the lighter as shown in the General Visual Weight Table. This does not apply to architectural details such as cornices, window sills, and beltlines. 4. No more than three different exterior finish materials, textures, colors, or combinations thereof may be used on a single building, excluding materials used on windows, doors, front porches, balconies, foundations, awnings, or architectural details. 5. Foundations must be constructed as a distinct building element that is finished in a different material or color than the exterior wall. Exposed above-ground foundations must be coated or faced in cement, hard coat stucco, brick, manufactured stone, or natural stone to contrast with façade materials. C. Building Facade. 1. The following applies to all street-facing facades. 2. Where used, shutters must match one half the width and shape of the window opening to which they are adjacent. 3. Facades must provide visual divisions between the ground story and second story through architectural means such as courses, awnings, or a change in materials. 4. Facades must delineate all stories above the ground story with windows, belt courses, balconies, cornice lines or similar architectural detailing. 5. Windows above the ground story must be equally sized, vertically oriented, equally spaced and arranged in a grid pattern. 6. Windows must be recessed a minimum of 3 inches and a maximum of 8 inches from the adjacent façade. D. Building Massing. 1. Facades over 50 feet in length must incorporate wall projections or recesses a minimum of 12 inches in depth. The combined length of said recesses and projections must constitute at least 20% of the total facade length. 2. Variation in the roofline of buildings and offsets in pitched roofs and gables are required. Parapets in individual building facades exceeding 100 continuous linear feet must be varied in height and projection and must use decorative elements such as crown moldings, dentals, brick soldier courses, or similar details. 3. The roofs of buildings may include cisterns and greenroofs if part of an approved stormwater management plan for the site and if designed in accordance with the GA Stormwater Management Design Manual (latest version). Above-ground cisterns require architectural and/or landscape screening that compliments the architecture of the building and is of like or similar materials used in the building's construction. The cisterns and other vertical runoff reduction measures and their screening shall require approval by the Community Development Director. 2.8.6. Small Residential Building Standards. A. Applicability. The following applies to detached houses, carriages houses, cottage courts, semi-detached houses, townhouses, walk-up flats, stacked flats, and commercial houses. B. Building Materials. 1. The exterior finish material on all walls is limited to brick, manufactured stone, natural stone, wood siding, cement-based siding and/or hard coat stucco. [image omitted; see the official code] 2. Exterior finish materials must be combined only horizontally, with the visually heavier below the lighter as shown in the Small Residential Building Visual Weight Table. This does not apply to architectural details such as cornices, window sills, and beltlines. 3. No more than three different exterior finish materials, textures, colors, or combinations thereof may be used on a single building, excluding materials used on windows, doors, porches, balconies, foundations, or architectural details. 4. Foundations must be constructed as a distinct building element that is finished in a different material or color than the exterior wall. Exposed above-ground foundations must be coated or faced in cement, hard coat stucco, brick, manufactured stone, or natural stone to contrast with façade materials. C. Building Facades. 1. The following apply to all street-facing facades. 2. Windows and Doors a. Where used, shutters must match one half the width and shape of the window opening to which they are adjacent. b. Doors and windows that operate as sliders are prohibited. c. All windows must be vertically shaped with a height greater than width, except for windows that are part of a door or otherwise appropriate for a required architectural style. The top of said windows must generally be in alignment with the top of the adjacent door frame. d. Windows must have true or simulated divided lights or be one-over-one lights. e. Windows must include sills of wood, masonry, stone, cast stone, or terra cotta. f. Window frames must be recessed a minimum of 1.5 inches from the exterior façade. 3. A stoop or front porch is required. 4. Awnings are not allowed. D. Building Massing. 1. Pitched roofs, if provided, must be symmetrically sloped no less than 5:12, except that roofs for front porches and attached sheds may be no less than 2:12. 2. Flat roofs must be enclosed by parapets a minimum of 42 inches high, or as required to conceal mechanical equipment by Section 2.5.4. 3. All roofs must have a minimum 25-year roof life and no visible roll roofing. 4. Chimneys, where provided, must extend to the ground and must be faced in brick or stacked stone. 2.8.7. Architectural Style Requirements. A. Applicability. 1. This section only applies to detached houses, cottage courts, and carriages houses that are accessory to a detached house or cottage court. All other building types must comply with the requirements and procedures found in the Downtown Alpharetta Design Guidelines amendment to the Alpharetta Design Review Ordinance and Design Guidelines. 2. This section is further limited to not apply to parcels zoned R-12 or R-15 when such parcels are located within a recorded subdivision that existed on the date of adoption of this ordinance. 3. This section is further limited to only apply to new construction, modification, addition, alteration, moving, destruction or demolition which would affect the exterior appearance of any structure, building, land, site or other object, as follows: a. The demolition of any building, structure or object. b. The moving or relocation of any building, structure or object. c. Except housecleaning, any material work on the exterior appearance of existing buildings by additions, reconstruction, rehabilitation, alteration or any maintenance (including exterior color), or any exterior material changes. d. Any new construction of a principal building or accessory building or structure subject to view from a street or public way. B. Administration. 1. Conformance with this section is determined by the Director of Community Development. The Director of Community Development may grant relief from one or more requirement when: a. The requirement is unique to this section and is not otherwise required by the Unified Development Ordinance, another section of the Downtown Overlay, a Downtown District, or any other applicable local, State, or Federal regulation; and b. The relief does not cause substantial detriment to the public good or impair the purpose and intent of this Overlay. 2. Appeals of a decision by the Director of Community Development shall be made to the Board of Appeals for interpretation. C. General Requirements. 1. All buildings must be designed in one of the following architectural styles: a. Georgian b. Federal/Adam c. Greek Revival d. Neoclassical e. Stick f. Queen Anne g. Shingle h. Folk Victorian i. Romanesque j. Italianate k. Tudor Eclectic l. Beaux Arts m. French Colonial n. French Eclectic o. French New Traditional 2. Specific elements of the required styles are identified in Section 2.8.7.D through M. More information on each style can be found in A Field Guide to American Houses by Virginia Savage McAlester, Residential Architectural Styles in Georgia by the Historic Preservation Division of the Georgia Department of Natural Resources, or other architectural resources. D. Georgian. Elements of the Georgian style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades are always symmetrical and usually five windows wide. Narrower houses are sometimes three windows wide and larger houses are sometimes seven windows wide. There is never an even number of windows across the front façade. Front Doors Front doors are paneled, centered, and topped with a decorative crown support by decorative pilasters. There is also usually a row of small rectangular glass panes beneath the crown, either within the door or in a transom. Windows (visible from a street or civic space only) Windows have double-hung sashes, typically with nine or twelve small panes per sash. Windows are never in adjacent pairs. Cornices The cornice is usually emphasized with tooth-like dentils or other decorative molding. E. Federal/Adam. Elements of the Federal/Adam style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades are always symmetrical and usually five windows wide. Narrower houses are sometimes three windows wide and larger houses are sometimes seven windows wide. There is never an even number of windows across the front façade. Front Doors Front doors are paneled, centered, and topped with a semi-circular or elliptical fanlight. There are also usually sidelights, an elaborate crown and surround, and/or an extended small entry porch. Windows (visible from a street or civic space only) Windows have double-hung sashes, typically with six panes per sash. Windows are never in adjacent pairs. Cornices The cornice is usually emphasized with tooth-like dentils or other decorative molding. F. Greek Revival. Elements of the Greek Revival style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades of the principal building mass are usually symmetrical. Exceptions to this are limited to off-centered doors, which may be located at one side of the structure, especially in narrower detached houses. Front Doors Front doors include a narrow line of transom and sidelight windows, usually incorporated into an elaborate door surround. Front entry porches or full-width porches are usually provided. Porch roofs are always supported by square or rounded columns of one of the Classical Orders. Cornices The cornice is emphasized with a wide, divided band of trim. Roof The roof is usually gabled or hipped with a low pitch. G. Neoclassical. Elements of the Neoclassical style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades are always symmetrical and usually five windows wide. Narrower houses are sometimes three windows wide and larger houses are sometimes seven windows wide. There is never an even number of windows across the front façade. Front facades are usually dominated by a full-height entry porch with a triangular gable above supported by four columns with shallow square bases. Front Doors Front doors are paneled, centered, and topped with a semi-circular or elliptical fanlight. Windows Windows have double-hung sashes. ;l0; H.\Stick. Elements of the Stick style are as follows, although it's rare for one building to have all elements: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades are usually asymmetrical and include horizontal and vertical bands raised from the wall surface for emphasis. Front porches or stoops are always provided and include diagonal or curving support braces. Roofs Roofs are steeply pitched. When roof gables are provided they include decorative trusses. Cross gables are common. I. Queen Anne. Elements of the Queen Anne style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades of the principal building mass are usually asymmetrical. Front facades include a partial- or full-width porch and extend along one or both side walls. All facades often include textured shingles or other devices to avoid a smooth-walled appearance. Roofs Roofs are steeply pitched. J. Shingle. Elements of the Shingle style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades are always asymmetrical. Front porches are almost always present. Wall cladding and roofs are of continuous wood shingles. Shingled walls turn corners without interruption. Roofs Roofs have irregular, steeply pitched roof lines, usually with cross gables and multi-level eaves. K. Folk Victorian. Elements of the Folk Victorian style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades are always symmetrical, except when a front gable or wing is provided. Front porches are provided and have spindlework detailing. Roofs Roofs are usually gabled and with very simple massing. Roofs include brackets under eaves. L. Romanesque. Elements of the Romanesque style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades of the principal building mass are usually asymmetrical. Walls are of masonry. Round top arches are provided over windows or entrances. Roofs Roofs shapes vary, but there are conical roofs on towers, when such are provided. M. Italianate. Elements of the Italianate style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Facades are usually two or three stories. Windows Windows often have elaborate crowns, usually of an inverted U-shape. Windows are tall, narrow, and often arched above. Roofs Roofs are low pitched with widely overhanging eaves supported by decorative brackets. Roofs often include a square cupola or tower. N. Tudor Eclectic. Elements of the Tudor Eclectic style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Facades dominated by one or more prominent front-facing gables, usually steeply pitched. Front door and/or entry porch with round or Tudor arch. Decorative half-timbering, but not present on all examples. Windows Tall, narrow windows, usually in multiple groups, with multi-pane glazing. Roofs Steeply pitched roof, usually side-gabled. Massive and prominent chimneys, usually capped with decorative clay pots. O. Beaux Arts. Elements of the Beaux Arts style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades are usually symmetrical. Masonry walls, usually of light colored stone, with heavy bases of large, rusticated stone blocks. Use of Classical columns, cornices, quoins, and pilasters. Windows Windows are usually tall and topped with decorative garland, floral patterns, or shield details. Roofs Flat or symmetrical roof forms. P. French Colonial. Elements of the French Colonial style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades are usually symmetrical. Walls are typically faced in true stucco. Doors and Windows Tall, narrow door and windows openings. Door and window sashes are typically divided vertically into panes. Roofs Steeply pitched roof, either hipped or side gabled. Q. French Eclectic. [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades are usually symmetrical. Segmented arches are commonly found in doors, windows, and dormers. Brick, stone, or stucco wall cladding, sometimes with false half timbering. Windows Window sashes are typically divided into panes. Roofs Tall, steeply pitched roofs (occasionally gabled) with no dominant front-facing cross gable. Roof eaves that often flair upwards at roof-wall junctions. R. French New Traditional. The French New Traditional style draws upon the three French styles identified earlier in this section, but is a unique style due to the way it blends elements from the various French styles. Elements of the French New Traditional Style are as follows: [image omitted; see the official code] Source: A Field Guide to American Houses by Virginia Savage McAlester Façade Composition Front facades may be symmetrical or asymmetrical. Brick, stone, or stucco wall cladding. Architectural details that reflect historic precedents but are less intricate and generally mass-produced. Windows Tall door and windows openings. Roofs Moderate to steeply pitched roof. 2.8.8. Storefront Street Requirements. A. Applicability. These regulations apply to the portions of sites abutting the street segments designated in the Downtown Alpharetta Storefront Street Table. Downtown Alpharetta Storefront Street Table Street | Street Segment | Side of Street From: | To: Milton Avenue | A point 400 feet west of the intersection with Canton Street (centerline) | State Route 9/Main Street | Both sides Academy Street | State Route 9/Main Street | Manning Street | Both sides State Route 9/Main Street | A point 200 feet north of the intersection with Milton Avenue/Academy Street | Marietta Street | Both sides B. Building Type Restrictions. Buildings abutting a street segment identified in the Downtown Alpharetta Shopfront Table are limited to Mixed-Use Buildings or Shopfronts. Additional building types may be provided to the rear of a conforming Mixed-Use Building or Shopfront.
(Ord. No. 732, § 46, 2-6-2017) (Ord. No. 748, §§ 1, 2, 9-18-2017; 758, §§ 1, 2, 5-7-2018)
Ask a question about Alpharetta law
Corpus searches the Alpharetta sections it holds and shows the ones that match, with their citations. Free, no sign-in.