Sec. 20-4. - Sprinkler installation and protection.

(a) Purpose. Certain properties within the incorporated limits of the City of Alpharetta, as designated in subsection (c), may be required to install and maintain a sprinkler system. Any such system must be designed in accordance with the National Fire Protection Association (NFPA) standards and adhere to the requirements set forth in this section of the Code. If this section in any way conflicts with the provisions in the International Building Code, the International Fire Code, or other applicable codes adopted by the city, the more restrictive shall apply. (b) Occupancy classifications. The standards set forth in this section shall be set based on the following occupancy classifications: (1) Class 1 occupancy covers manufactured homes, a detached residential structure designed for single-family occupancy, and attached residential structures designed with a maximum of two dwelling units for single-family occupancy, such as a duplex. (2) Class 2 occupancy covers attached residential structures designed with three or more attached dwelling units for single-family occupancy, such as townhouses, and multi-family residential structures, such as apartments and condominiums. (3) Class 3 occupancy covers all commercial-based structures. (c) Voluntary sprinkler protection system. Class 1 dwellings may voluntarily install a sprinkler system. Any such properties opting to install such a system must comply with the design criteria established in NFPA 13D as adopted by Georgia's Office of Insurance and Safety Fire Commissioner. (d) Required sprinkler protection system. If not otherwise required by the State Minimum Rules and Regulations as adopted by the city, the following buildings shall be protected with an approved sprinkler system as follows: (1) Class 2 occupancies. All Class 2 residential dwellings shall be constructed with a sprinkler system that complies with the design criteria established in NFPA 13R or NFPA 13D, per the respective International Residential Code or International Building Code, as adopted by Georgia's Office of Insurance and Safety Fire Commissioner. (2) Class 3 occupancies. In addition to requirements instituted by the State of Georgia, the City of Alpharetta shall require sprinkler systems in the following commercial properties: a. Mercantile occupancies exceeding 5,000 square feet or, if less than 5,000 square feet, if the building is more than one story in height. This requirement shall not apply if 50 percent or more of the square footage is a covered open air structure, such as a pavilion; b. Business occupancies exceeding 7,500 square feet, unless otherwise required by state or local law; c. Storage occupancies exceeding 5,000 square feet, unless otherwise required by state or local law; d. Industrial occupancies exceeding 5,000 square feet, unless otherwise required by state or local law; e. Buildings that have a primary use of educational occupancy, with the exception of mobile or portable classrooms or modular units of less than 5,000 square feet. f. All strip malls, regardless of occupancy use. For the purposes of this section, strip mall means a single building or group of attached buildings arranged in a linear configuration containing two or more separate commercial tenant spaces that share common walls and are served by a common parking area, with each tenant space having a separate public entrance directly accessible from the exterior of the building. (3) Assembly occupancies. If not otherwise required by the State Minimum Rules and Regulations as adopted by the city, the following assembly occupancies shall be protected with an approved, electrically supervised automatic sprinkler system: a. Assembly occupancies with festival seating. b. Places of worship. c. Restaurants. d. Bars. e. Nightclubs. f. Dance halls. g. Discotheques. (e) Applicability. This section shall apply to all new buildings and to any existing buildings or structures that shall be deemed a new building due to substantial renovations or modifications. "Substantial renovation" shall mean any construction project of such building or structure costing more than the building's or structure's gross assessed value according to the Fulton County tax assessor at the time of starting such renovation. "Substantial modification" shall mean either an interior modification that involves an aggregate of 50 percent of existing square feet or greater or in which a change in occupancy class triggers the existing provisions of this Code section. The property owner is responsible for the inspection and testing of the sprinkler system in accordance with the rules of the state safety fire commissioner on all structures required to have sprinkler systems. (f) Authority of the fire marshal. The Alpharetta Fire Marshal has authority to require a class III sprinkler system for any structure or occupancy that does not fall under one of the above-listed classifications if the building or structure is deemed to be hazardous, regardless of building size. The fire marshal shall have the power to enforce the requirements in this section, including issuing a notice to any property owner in noncompliance with this section and a set date to come into compliance, the issuance of citations to be prosecuted pursuant to article IV of the Charter for the City of Alpharetta, may apply to the Superior Court of Fulton County for an order requiring the property owner to comply, or any other legal remedies allowable under local and state law. (g) Effective date. The requirements of this Code section shall apply to the buildings and properties with land disturbance or building permits issued on or after July 1, 2026.

(Ord. No. 908, Exh. A, 8-2-2026)

Ask a question about Alpharetta law

Corpus searches the Alpharetta sections it holds and shows the ones that match, with their citations. Free, no sign-in.