Sec. 20-8. - Emergency responders radio coverage and testing.

(a) Purpose. Emergency responder radio coverage systems shall be provided, tested, and certified where required by the adopted International Fire Code, NFPA 1225, and applicable Georgia State Minimum Fire Safety Standards. Testing and certification required for issuance of a certificate of occupancy or final approval shall be performed only by vendors approved by the North Fulton Regional Radio System Authority (NFRRSA). (b) Definitions. The following words, terms, and phrases, when used in this article, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: Approved vendor means a company or individual that has been reviewed, qualified, and listed as an approved service provider by the NFRRSA. Certification means the formal documentation confirming that an ERRC system complies with IFC Section 510 and all applicable city and NFRRSA requirements. Emergency responder radio coverage means a system designed to enhance in-building radio signal strength for first responders as required under IFC Section 510. Initial testing means the first comprehensive performance and compliance testing of a newly installed ERRC system prior to its approval for operation use. Minimum signal strength means the minimum required radio signal strength within a building, set by the city and NFRRSA as -95 decibels per milliwatt (dBm) and a delivered audio quality (DAQ) no less than 3.0. Needs assessment testing means the evaluation process conducted to determine whether a building or structure requires an ERRC system, as specified in IFC Section 510 and any adopted amendments. (c) Requirements. Needs assessment testing and initial testing must be performed by an approved vendor. Certification for an ERRC system will only be issued following satisfactory testing by an approved vendor. All testing must be completed and approved by the fire marshal before a certificate of occupancy can be issued. (d) Pathway infrastructure for new construction. (1) Any newly-constructed building, structure, or occupancy required under adopted fire codes, IFC Section 510, or this Code, to undergo emergency responder radio coverage testing, or needs assessment testing, shall be provided with reasonable pathway infrastructure to facilitate future installation of an emergency responder radio coverage system if later required. (2) Pathway infrastructure may include conduit, raceways, riser access pathways, designated equipment space, electrical capacity, and other construction features reasonably necessary to reduce delay, demolition, or excessive retrofit costs associated with future ERRC system installation. (3) Specific pathway requirements may be established by administrative policy, plan review standards, or technical guidance issued by the fire marshal in coordination with applicable building officials. (e) Enforcement and penalties. The Alpharetta Fire Department shall have the power to enforce this code section. Failure to comply with the ERRC requirements may result in revocation of building permits or certificates of occupancy, the issuance of citations to be prosecuted pursuant to article IV of the Charter for the City of Alpharetta, or any other legal action as permitted under local and state law.

(Ord. No. 908, Exh. A, 8-2-2026)

Ask a question about Alpharetta law

Corpus searches the Alpharetta sections it holds and shows the ones that match, with their citations. Free, no sign-in.