For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16-20V.014 — Development controls

Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code § 16-20V.014

Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/4609f26d-fd87-4f1a-b831-aa65f59fa5fd

Sec. 16-20V.014. - Development controls.

All development must comply with Table 2 "Poncey-Highland Historic District Development Controls Table," Table 3 "Poncey-Highland Subarea 1 Lot Coverage Table," Table 4: Poncey-Highland Historic District Building Height Table," and with subsections 1 through 4. "CR" refers to the compatibility rule. Table 2: Poncey-Highland Historic District Development Controls Table Key CR = Per the compatibility rule | SUBAREA 1 Residential Core | SUBAREA 2 BeltLine Residential | SUBAREA 3 N. Highland Mixed-use | SUBAREA 4 Ponce de Leon Mixed-use | SUBAREA 5 BeltLine Mixed-use | SUBAREA 6 Bonaventure-Somerset Residential | SUBAREA 7 Transitional Maximum FAR (times net lot area) | 0.5 | 0.85 | 3.2 [1] | 3.2 [1] | 8.2 [1] | 0.5 | n/a Minimum Lot Area | CR | CR | 800 sf | 800 sf | 800 sf | CR | n/a Minimum Lot Width | CR | CR | 16 ft. | 16 ft. | 16 ft. | CR | n/a Yard Requirements Front [2] | CR | CR | CR. | 5 ft. min/30 ft max. | 5 ft min | CR | n/a Side (detached houses,) | CR, but 3 ft. min. | CR, but 3 ft. min. | 0 ft min. | 0 ft. min. | 0 ft. min. | CR, but 3 ft. min. | n/a. Side (carriage houses) | 3 ft. min. | 3 ft. min. | 0 ft. min. | 0 ft. min. | 0 ft. min. | 0 ft. min. | n/a Side (all other building types) | 7 ft. min. | 7 ft. min. | 0 ft. min. | 0 ft. min. | 0 ft. min. | 7 ft. min. | n/a Rear (detached houses) | CR, but 5 ft. min. | CR, but 5 ft. min. | 5 ft. min. | 5 ft. min. | 5 ft. min. | CR, but 5 ft. min. | n/a Rear (carriage houses) | 3 ft. min. | 3 ft. min. | 3 ft. min. | 3 ft. min. | 3 ft. min. | 3 ft. min. | n/a Rear (all other building types) | 7 ft. min. | 7 ft. min. | 5 ft. min. | 5 ft. min. | 5 ft. min. | 7 ft. min. | n/a Maximum Lot Coverage [3] | See Table 3 | See Table 3 | 85% | 85% | 85% | See Table 3 | n/a Minimum Open Space Requirements [4] Non-residential uses | None | None | 10% net lot area as UOSR | 10% net lot area as UOSR | 10% net lot area as UOSR | None | n/a Residential uses | None | None | Table I, "Land use intensity ratios" UOSR | Table I, "Land use intensity ratios" UOSR | Table I, "Land use intensity ratios" UOSR | None | n/a Tables Notes: [1] FAR in this subarea excludes any floor area in buildings built before 1945. [2] Measured from the back of the required sidewalk along all public and private streets. [3] Lot coverage excludes areas deemed "pervious" by the Post Development Stormwater Management Ordinance. [4] There is no minimum open space requirements for buildings built before 1945. Useable open space (UOSR) has the meaning set forth in Sec. 16-28.010(5). Table 3: Poncey-Highland Subarea 1, 2, and 6 Lot Coverage Table Lots of record in the indicated Subareas 1, 2, and 6 are subject to the following maximum lot coverages. Lot of Record Size | Subarea 1 | Subarea 2 | Subarea 6 4,499 sf or smaller | 70% max. | 80% max. | 70% max. 4,500 sf to 4,999 sf | 68% max. | 78% max. | 68% max. 5,000 sf to 5,999 sf | 66% max. | 76% max. | 66% max. 5,500 sf 6,000 sf | 64% max. | 74% max. | 64% max. 6,000 sf to 5,999 SF | 62% max. | 72% max. | 62% max. 6,500 sf to 6,749 SF | 60% max | 70% max | 60% max 7,000 sf to 7,499 sf | 58% max. | 68% max. | 58% max. 7,500 sf to 7,999 sf | 56% max. | 66% max. | 56% max. 8,000 sf to 8,499 sf | 54% max. | 64% max. | 55% max. 8,500 sf to 8,999 sf | 52% max. | 62% max. | 55% max. 9,000 sf or larger | 50% max. | 60% max. | 55% max. Table 4: Poncey-Highland Historic District Building Height Table General building height standards. These only apply in areas not subject to the additional restrictions below. Key CR = Per the compatibility rule. See Sec. 16-20V.014(1) Note Heights shown in this table must be reduced by the transitional height plane, when applicable. | SUBAREA 1 Residential Core | SUBAREA 2 BeltLine Residential | SUBAREA 3 N. Highland Mixed-use | SUBAREA 4 Ponce de Leon Mixed-use | SUBAREA 5 BeltLine Mixed-use | SUBAREA 6 Bonaventure-Somerset Residential | SUBAREA 7 Freedom Park Transitional Building Height Standards | CR | CR | 78 ft. max., 18 ft. min. (see additional restrictions below) | 85 ft. max., 30 ft. min. (see additional restrictions below) | 185 ft max. (see additional restrictions below) | CR | 35 ft. max. Additional building height restrictions. The general building height standards above will be further restricted in the following areas: Subareas 4 and 5 only for portions of buildings within 60 feet of Subarea 1, 2, or 6 | 52 ft. max. Subarea 3 east of N. Highland Avenue | 3 stories or 42 ft max., whichever is less, for first 10 feet of building depth; and 6 stories or 78 feet, whichever is less, in other locations Subarea 3 west of N. Highland Avenue | 3 stories or 42 ft max., whichever is less, for first 10 feet of building depth; and 4 stories or 54 feet, whichever is less, in other locations Subarea 4 east of Freedom Parkway | 5 stories or 75 ft. max., whichever is less [1] Subarea 4 west of Freedom Parkway | 6 stories or 85 ft. max., whichever is less [1] Table Notes: [1] The maximum building height may be increased by one story or 15 ft. maximum in order to divide the street-facing building façade into vertical divisions per section 16-20V.015(18)(b)(i), provided such increased height does not constitute more than 30% of the total building footprint, or the maximum building height may also be increased by one story or 15 ft. maximum on sites where no upper story additions are proposed for contributing historic buildings. (1) Lot compatibility zone height requirements. The following height standards apply in the lot compatibility zone: (a) On blocks with at least one historic two-story building (measured along the façade facing the public street), the maximum building height is determined by the compatibility rule. (b) On all other blocks, the maximum building height is 30 feet. (2) Open space requirements. (a) Mixed-use developments. When a development contains any combination of nonresidential or residential uses, the minimum open space requirement is based on whichever such use has the greatest floor area. (b) Open space areas. The following may be used to satisfy open space requirements: (i) Useable open space; (ii) New public or private streets required under "3" below. (iii) Future connectivity required under "4" below. (iv) Vegetated roofs; (v) New on-street parking if on-street parking currently does not exist in the public right-of-way adjacent to the development and the new on-street parking is located where there is no existing street lane; and (vi) Stormwater ponds that serve multiple buildings or lots, in accordance with the current City of Atlanta Stormwater Design Manual, when said ponds have been designed by a qualified professional as formal or natural amenities that incorporate additional functions other than stormwater management into their design, including, but not limited to aesthetic appeal, seating, boardwalks, and similar features. Said ponds may not be fenced or enclosed by retaining walls over 30 inches in height. (3) Blocks. Developments in Subarea 5 proposing to contain an entire block face greater than 600 feet in total frontage along an existing public or private street must incorporate new streets that conform to the following: (a) New streets must create block faces not exceeding 400 feet in length, unless a larger block size is required by chapter 36 of this part to accommodate a new street location required by the Beltline Street Framework Plan. (b) Block face length is measured from the back of sidewalk clear zones. (c) New streets used to satisfy this requirement: (i) May be public or private, but must function as public streets; (ii) May not be gated; and (iii) Must connect two (2) other public streets or private streets. (4) Future connectivity. No development in Subarea 3, 4, or 5 may be designed to prohibit or obstruct the ability for future vehicle, bicycle, and pedestrian connections to adjacent lots, including through the use of new public or private streets, except when the Director determines that such is impractical due to topographic or other site-specific constraints. This provision may not be interpreted to prohibit or restrict something which would otherwise be permitted in this district or require inter-parcel rights to be granted to adjacent property owners.

(Ord. No. 2020-49(20-O-1171), § 3(Att. C), 9-17-20)

Ask a question about Atlanta law

Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.