Sec. 16-20V.008. - Subarea 1, 2, and 6 construction of all new building types.
New principal buildings in Subareas 1, 2, and 6 must meet all applicable provisions of this section and either section 16-20V.008(1) Original/Historic Architectural Forms and Styles OR section 16-20V.008(2) Contextual Architectural Forms and Styles, but not a combination of both. (1) Original/historic architectural forms and styles. The following regulations apply to facades within the lot compatibility zone: (a) Building facades. (i) Must be an architectural style of a historic/contributing building of like use on the block face. (ii) Must have a front porch facing and parallel to the street. (b) Materials, elements, and ornamentation. Building materials, architectural elements, and ornamentation must meet the compatibility rule and must be internally consistent with the architectural style. (c) Windows and doors. (i) The ratio of window and door opening area to wall area must meet the compatibility rule and must be internally consistent with the architectural style. (ii) The scale, size, proportion, and location of all window and doors openings must meet the compatibility rule and must be internally consistent with the architectural style. (iii) The front door must be visible from and face the public street. (d) Siding and façade sheathing. Must meet the compatibility rule and must be internally consistent with the architectural style. Further, brick, brick veneer, true stucco, wood or smooth faced cementitious shingles, or horizontal wood or smooth faced cementitious lap siding are the only permissible building materials for the facades. (e) Foundation. (i) Slab on grade, raised slab, or turn-down slab foundations are not permitted. (ii) Foundation material must meet the compatibility rule and must be internally consistent with the architectural style. (f) Roofs and roof materials. (i) Form and pitch, as well as ridge, overhang, and soffit construction must meet the compatibility rule and must be internally consistent with the architectural style. (ii) Clay tile, slate, composition asphalt shingles, fiberglass shingles, metal shingles, and solar energy generating shingles are permissible roofing materials. (iii) Solar panels are permissible only outside of the lot compatibility zone. (iv) Membrane, cold-rolled, and corrugated roofing are permitted only on roofs outside of the lot compatibility zone. (g) Chimneys. (i) When any portion of a chimney is a façade element, the chimney must originate at grade. (ii) Exterior portions of chimneys must be faced with brick, brick veneer, or true stucco. Siding on chimneys is not permitted. (h) Porches. (i) Porches are required. The dimensions, location, and shape must meet the compatibility rule and must be internally consistent with the architectural style. (ii) Required porches must contain balustrades, columns, and other features which shall meet the compatibility rule and must be internally consistent with the architectural style. Additional height needed to meet building codes must be attained by using a distinct railing extension. (i) Shutters. Shutters may be used if they are internally consistent with the architectural style. Shutters must be operable, or appear operable, and must fit the size of the window. (j) Decks and balconies. (i) Decks are only permitted at the rear of the principal structure and must not project past the side façade of the principal structure. Decks are permitted at any level. (ii) Balconies are permitted on any façade if they are internally consistent with the architectural style. (2) Contextual architectural forms and styles. The following regulations apply to those facades which are within the lot compatibility zone within Subareas 1 and 6: (a) Contextual architectural forms and styles shall be all forms and styles that do not conform to the requirements of section 16-20V.008(1) Original/Historic Architectural Forms and Styles, but do comply with this section, section 16-20V.008(2). (b) Materials, elements, and ornamentation. Building materials, architectural elements, and ornamentation must be internally consistent with the architectural style. (c) Windows and doors. (i) The ratio of window and door opening area to wall area must be internally consistent with the architectural style. (ii) The scale, size, proportion, and location of all window and door openings must be internally consistent with the architectural style. (iii) The principal front door must be visible from and face the public street. (d) Siding and façade sheathing. Must be internally consistent with the architectural style. Brick, brick veneer, stone, true stucco, wood or smooth faced cementitious shingles, wood or smooth faced cementitious lap siding, or smooth faced cementitious panels are permissible building materials for facades. When installed within the lot compatibility zone, smooth faced cementitious panels may not utilize a board and batten application. All panels must include a metal reveal channel, lap joint, expansion joint, or rain screen as an alternative to battens. (e) Foundation materials. Must be internally consistent with the architectural style. (f) Roofs and roof materials. (i) Form and pitch, as well as ridge, overhang, and soffit construction must be internally consistent with the architectural style. (ii) Clay tile, slate, composition asphalt shingles, fiberglass shingles, metal shingles, metal panels, and solar energy generating shingles are permissible roofing materials. (iii) Solar panels are permissible outside of the lot compatibility zone. (iv) Membrane or cold-rolled roofing is permitted only on roofs outside the lot compatibility zone. Corrugated roofing materials are not permitted. (g) Chimneys. (i) When any portion of a chimney is a façade element, the chimney must originate at grade. (ii) Exterior portions of chimneys must be faced with brick, brick veneer, or true stucco. Siding on chimneys is not permitted. (h) Shutters. Shutters are not permitted. (i) Decks and balconies. (i) Decks are only permitted at the rear of the principal structure and at any level and must not project past the side façade of the principal structure. Decks are permitted at any level. (ii) Balconies are permitted on any façade if it is internally consistent with the architectural style.
(Ord. No. 2020-49(20-O-1171), § 3(Att. C), 9-17-20)
Ask a question about Atlanta law
Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.