For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16-20V.015 — Building type standards

Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code § 16-20V.015

Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/ec18b9e5-3ba6-4a00-92dd-89ef981830fb

Sec. 16-20V.015. - Building type standards.

The following building type regulations apply to all subareas: (1) All principal existing and proposed principal buildings must comply with the requirements of this section, as applicable to the specific building type. (2) Where a development contains multiple building types, the requirements of each building type must be met independently as if each building was located on its own lot, even when no subdivision is proposed. (3) Parking structures fronting or visible from a street or the BeltLine corridor must also select and comply with the following standards for one building type: (a) Building massing and active uses, (b) Pedestrian access, (c) Building elements, (d) Fenestration, and (e) Parking location. The building type utilized must be allowed in the subarea. (4) Applicants must select which allowed building type corresponds to the building they are proposing to construct, alter, or add to and must comply with the standards for that building type as it relates to that new construction, alteration, or addition. All building types selected must be approved by the Director. (5) Table 5: Allowed Building Types identifies the new building types allowed by subarea. Each building type may contain any use allowed in the subareas in which it is located unless otherwise noted by building type. On lots of record that contained legal building types other than those allowed by Table 5 before January 1, 2020, such other building types are allowed for new construction, alteration, or addition. Table 5: Allowed New Building Types Building Type | SUBAREA 1 Residential Core | SUBAREA 2 BeltLine Residential | SUBAREA 3 N. Highland Mixed-Use | SUBAREA 4 Ponce de Leon Mixed-use | SUBAREA 5 BeltLine Mixed-use | SUBAREA 6 Bonaventure-Somerset Residential Detached House | Yes | Yes | Yes [1] | Yes [1] | Yes [1] | Yes Carriage House | Yes | Yes | Yes [1] | Yes [1] | Yes [1] | Yes Cottage Court | No | Yes | Yes | Yes | No | No Townhouse | No | Yes | Yes | Yes | Yes | No Stacked Flat | No | No | Yes | Yes | Yes | No Shopfront | No | No | Yes | No | No | No Commercial Block | No | No | Yes | Yes | Yes | No Tower | No | No | No | No | Yes | No Civic | Yes | Yes | Yes | Yes | Yes | Yes Tables Notes: [1] Building type only allowed when used to meet the transitional yard provisions of Sec. 16-20V.13(2)(b). (6) All principal buildings must be oriented to the street they face or the BeltLine corridor, when applicable. (7) Where multiple building types are proposed for a single lot, the proposal must include potential lot lines for each building type, which conform with this Chapter 20V, the purpose of which is only to determine compliance with building type standards. (8) The standards for building types do not apply to accessory structures, except carriage houses, and except parking structures as provided for in section 16-20V.015(3) above. (9) Detached house standards. The following applies to all detached houses. (a) Description A detached house is a small-scale, freestanding building, set back from the public street, elevated above the ground level and designed to facilitate residential uses. | [image omitted; see the official code] (b) Building Density Dwelling units per building | 2 max. (either 1 principal dwelling + 1 ADU max.; or 2 principal dwellings max.) Buildings per lot | 1 max., excluding accessory buildings (c) Building Massing and Active Uses (see Sec. 16-20V.015(18)) Building height | See subarea requirements Street-facing façade width | n/a Active use depth | n/a (d) Pedestrian Access (see Sec. 16-20V.015(19)) Entrance facing street | Required Walkway width | 3 ft min./5 ft max. (e) Building Elements (see Sec. 16-20V.015(20)) Each detached house must provide a porch. The required porch must face the street. (f) Fenestration (see Sec. 16-20V.015(21)) Street-facing facades | 10% min. wall area per floor, excluding basements and attics (g) Parking location No on-site parking is allowed between the building and the street. Garage doors must be located on the side or rear facades of the principal structure and may not face a public street. (10) Carriage house standards. The following applies to all carriage houses. (a) Description A carriage house is a freestanding building, typically designed for use as a garage, storage, guest house, or accessory dwelling unit. A carriage house must be accessory to a principal dwelling and located on the same lot. | [image omitted; see the official code] (b) Building Density Accessory dwelling units per building | 1 max. Buildings per lot | 2 max. excluding principal buildings (c) Building Massing and Active Uses (see Sec. 16-20V.015(18)) Building height | See Sec. 16-20V.012 for accessory structure height Street-facing façade width | n/a Active use depth | n/a (d) Pedestrian Access (see Sec. 16-20V.015(19)) Entrance facing street | Not required Walkway width | n/a (e) Building Elements (see Sec. 16-20V.015(20)) n/a (f) Fenestration (see Sec. 16-20V.015(21)) Street-facing facades | n/a (g) Parking Location On-site parking location is regulated by the principal dwelling unit. (11) Cottage court standards. The following applies to all cottage courts. (a) Description A cottage court accommodates three to ten detached dwelling units located around a shared internal courtyard. Units must all be on the same lot and no unit may be located above or below another. Cottage courts are for residential uses. | [image omitted; see the official code] (b) Building Density Dwelling units per cottage court | 3 min. / 10 max. Buildings per lot | 10 max. excluding accessory buildings Floor area per dwelling unit | 1,200 sf max. (c) Building Massing and Active Uses (see Sec. 16-20V.015(18)) Building height | See subarea requirements Street-facing façade width | No min./no max. Active use depth | n/a (d) Courtyard Area | 3,000 sf min. Width | 40 ft. min. Courtyard may not be parked or driven upon, except for emergency access. (e) Pedestrian Access (see Sec. 16-20V.015(19)) Entrance facing street | Required for units along street Walkway width | 3 ft min./5 ft max. must connect all dwellings to the street (f) Building Elements (see Sec. 16-20V.015(20)) Each cottage court unit along a street and each cottage court units along a courtyard must provide either a: (i) Stoop, or (ii) Porch A porch is required when adjacent to a street. (g) Fenestration (see Sec. 16-20V.015(21)) Street-facing or courtyard-facing facades | 10% min. area per floor, excluding basements and attics (h) Parking Location No on-site parking is allowed between the building and the street or between buildings and the courtyard. Garage doors, if located on the principal structure must be located on the side or rear façade and may not face the interior of the court or a public street. (12) Townhouse standards. The following applies to all townhouses. (a) Description A townhouse is a building type that accommodates three or more dwelling units or tenant spaces where each unit is separated by a common sidewall. No unit may be located above or below another. | [image omitted; see the official code] (b) Density and Use Dwelling units per building | 3 min./no max. Buildings per lot | n/a (c) Building Massing and Active Uses (see Sec. 16-20V.015(18)) Building height | 52 ft max., except in subareas where a lower height limit applies Street-facing façade width | 16 ft min. /150 ft. max. Active use depth | 20 ft. min, except corner units are only required to meet this requirement along one street Percent of front lot width that must be abutted by a conforming townhouse building | 70% min., excluding transitional yards, existing alleys, and one new driveway (d) Pedestrian Access (see Sec. 16-20V.015(19)) Entrance facing street | Required for units along street Walkway width: | 3 ft min./5 ft max. must connect all dwellings to the street (e) Building Elements (see Sec. 16-20V.015(20)) Each townhouse unit facing a street must provide one of the following: (i) Stoop, or (ii) Porch, or (iii) Storefront Balconies are also allowed above the ground floor. (f) Fenestration (see Sec. 16-20V.015(21)) Street-facing facades | 20% min. area per floor (g) Parking Location No on-site parking is allowed between the building and the street. Garage doors may not face a street. (13) Stacked flat standards. The following applies to all stacked flats. (a) Description A stacked flat building is a multi-story building type that was originally built to accommodates four or more dwelling units located above or below another unit. Nonresidential uses are permitted in stacked flats when allowed by subarea regulations. | [image omitted; see the official code] (b) Building Density Dwelling units per building | 4 min./no max. Buildings per lot | n/a (c) Building Massing and Active Uses (see Sec. 16-20V.015(18)) Building height | See subarea requirements Street-facing façade width | 150 ft. max. Active use depth | 20 ft. min. Percent of front lot width that must be abutted by a conforming stacked flat building | 70% min., excluding transitional yards, existing alleys, and one new driveway (d) Pedestrian Access (see Sec. 16-20V.015(19)) Entrance facing street | Required for lobby (if provided) and when four or more ground floor units are along a street Walkway width: | 3 ft min./10 ft max. (e) Building Elements (see Sec. 16-20V.015(20)) n/a (f) Fenestration (see Sec. 16-20V.015(21)) Street-facing facades | 20% min. area per floor (g) Parking Location No on-site parking is allowed between the building and the street. ;adv=6;(14) Shopfront standards. The following applies to all shopfronts. (a) Description A shopfront is a single-story building containing pedestrian-oriented ground floor retail, restaurant, or service uses. Note: See commercial block standards for related standards for buildings more than one story in height. | [image omitted; see the official code] (b) Building Massing and Active Uses (see Sec. 16-20V.015(18)) Building height | See subarea requirements Ground floor height (floor to floor) | 16 ft. min Upper floor height (floor to floor) | 10 ft. min Street-facing façade width | 150 ft. max. Active use depth | 20 ft. depth and may not be dwelling units Percent of front lot width that must be abutted by a conforming shopfront building | 70% min., excluding transitional yards, existing alleys, and one new driveway (c) Pedestrian Access (see Sec. 16-20V.015(19)) Entrance facing street | Required for all tenant spaces along streets Walkway width: | 6 ft. min. (d) Building Elements (see Sec. 16-20V.015(20)) Each individual tenant space facing a street must provide an awning/canopy. (e) Fenestration (see Sec. 16-20V.015(21)) Street-facing facades | 70% min. area Street-facing blank wall | 20 ft. max. (f) Parking Location No exterior on-site parking is allowed between the building and the street. No interior, above-ground parking is allowed within 20 feet of a street-facing façade. (g) Building Type Location New shopfronts or commercial blocks must front North Highland Avenue. (15) Commercial block standards. The following applies to all commercial blocks. (a) Description A commercial block is a multi-story building designed for a vertical mix of uses, with pedestrian-oriented ground floor retail or service uses and upper floor residential, hospitality, or office uses. | [image omitted; see the official code] (b) Building Massing and Active Uses (see Sec. 16-20V.015(18)) Building height | See subarea requirements for min./7 stories max. Ground floor height (floor to floor) | 16 ft. min Upper floor height (floor to floor) | 10 ft. min Street-facing façade width | 150 ft. max. Active use depth | 20 ft. min. and may not be dwelling units Percent of front lot width that must be abutted by a conforming commercial block | 70% min., excluding transitional yards, existing alleys, and one new driveway (c) Pedestrian Access (see Sec. 16-20V.015(19)) Entrance facing street | Required for all ground floor tenant spaces along streets Walkway width: | 6 ft. min. (d) Building Elements (see Sec. 16-20V.015(20)) Each individual tenant space facing a street must provide an awning/canopy. (e) Fenestration (see Sec. 16-20V.015(21)) Street-facing ground floor facades | 70% min. area Street-facing upper floor facades | 20% min. area per floor Street-facing blank wall area | 20 ft. max. per floor (f) Parking Location No exterior on-site parking is allowed between the building and the street. No interior, above-ground parking is allowed within 20 feet of a street-facing façade. (g) Building Type Location New commercial blocks or towers must front Ponce de Leon Avenue. New commercial blocks or shopfronts must front North Highland Avenue. (16) Tower standards. The following applies to all towers. (a) Description A tower is a stacked unit or commercial block building of eight or more stories in height, which may include portions less than eight stories in height. | [image omitted; see the official code] (b) Building Massing and Active Uses (see Sec. 16-20V.015(18)) Building height | 8 stories min / see subarea requirements for mx. Ground floor height (floor to floor) | 16 ft. min Upper floor height (floor to floor) | 10 ft. min Street-facing façade width Portion of building under 8 stories in height | 150 ft max. Portion of building 8 or more stories in height | 250 ft max. Active use depth | 20 ft. min. and may not be dwelling units Percent of front lot width that must be abutted by a conforming tower | 70% min., excluding transitional yards, existing alleys, and one new driveway (c) Pedestrian Access (see Sec. 16-20V.015(19)) Entrance facing street | Required for all ground floor tenant spaces along streets Walkway width: | 6 ft. min. (d) Building Elements (see Sec. 16-20V.015(20)) Each individual tenant space facing a street must provide an awning/canopy. (e) Fenestration (see Sec. 16-20V.015(21)) Street-facing ground floor facades | 70% min. area Street-facing upper floor facades | 20% min. area per floor Street-facing blank wall area | 20 ft. max. per floor (f) Parking Location No exterior on-site parking is allowed between the building and the street. No interior, above-ground parking is allowed within 20 feet of a street-facing façade. (g) Building Type Location New towers or commercial blocks must front Ponce de Leon Avenue. (17) Civic standards. The following applies to civic buildings. (a) Description A civic building is designed to stand apart from its surroundings due to the special nature of its use as a public facility. Civic buildings may only be owned and used by the City of Atlanta, Fulton County, or other governmental entity; used for religious worship; or used for private schools. | [image omitted; see the official code] (b) Building Massing and Active Uses (see Sec. 16-20V.015(18)) Building height | See subarea requirements Ground floor height (floor to floor) | 16 ft. min Upper floor height (floor to floor) | 10 ft. min Street-facing façade width | 150 ft. max. Active use depth | 20 ft. min. (c) Pedestrian Access (see Sec. 16-20V.015(19)) Entrance facing street | Required Walkway width: | 6 ft. min. (d) Building Elements (see Sec. 16-20V.015(20)) n/a (e) Fenestration (see Sec. 16-20V.015(21)) Street-facing facades | 15% min. area per floor (f) Parking No exterior on-site parking is allowed between the building and the street. No interior, above-ground parking (either within the building or an accessory parking garage) is allowed within 40 feet of a public street. (18) Building type massing and active uses. (a) One primary mass required. (i) The main body of all principal buildings must consist of one primary mass. Secondary and incidental wings may be attached to the main body of a building. (ii) This requirement applies to each façade division set forth in "b" below. (b) Street-facing façade widths. These building massing standards apply to building types which include a street- facing façade width requirement. When required, buildings must use one of the following to divide the façade into the maximum street-facing width divisions shown for the building type in section 16-20V.015(9) through section 16-20V.015(17), as measured along the base of the façade: [image omitted; see the official code] (i) A change of façade material and window systems from grade to roof, and change of building height of at least one story; or (ii) A change in façade composition and/or architectural style from grade to the roof; or (iii) Similar means intended to convey the impression of separate buildings. Change in color alone, setback alone, or any combination of the two may not be used to satisfy this requirement. (c) Active uses. The ground floor of certain building types must provide "active uses" along public and private streets for the minimum indicated depth from the street-facing facade. For this purpose, "active use" means any permitted principal use with interior floor area that is served by plumbing, heating, and electricity. "Active use" specifically excludes parking; digital industry switchboards, relay equipment, and associated power generators; mechanical rooms; non-residential storage not associated with an industrial use; driveways; and queuing lanes parallel to the adjacent street. (19) Pedestrian access. (a) A pedestrian entrance and walkway providing ingress and egress, operable to residents at all times and operable to customers, visitors, and employees during business hours, is required to meet street-facing pedestrian entrance requirements. Additional entrances off another street, pedestrian area, open space, or internal parking area are allowed but must have the same or shorter hours of operability as the street-facing entrance. (b) A street address number must be located above the street-facing pedestrian entrance utilizing numbers that are at least six inches in height. When multiple entrances exist on a street-facing façade, only one address is required. (c) On corner lots, an angled or mitered pedestrian entrance may be provided along building corners to meet the street-facing pedestrian entrance requirements. (d) Building elements may be required to meet the street-facing pedestrian entrance requirements when required by building type. (20) Building elements. (a) Intent. The following apply when required by building type and are intended to ensure that certain building elements, when added to a street-facing façade, are of sufficient size to be both usable and functional and be architecturally compatible with the building they are attached to. (b) Front porch. A raised structure attached to a building, forming a covered pedestrian entrance to a doorway. (i) Front porches must conform to section 16-20V.006 through section 16-20V.008. (c) Stoop. A small raised platform that serves as a pedestrian entrance to a building. (i) A stoop must be no more than six feet deep (not including steps). (ii) A stoop may extend into the required yard but must not encroach into the public right-of-way or required sidewalk. (d) Balcony. A platform projecting from the wall of an upper story of a building with a railing along its outer edge, often with access from a door or window. (i) A balcony must be at least four feet deep. (ii) A balcony may extend into the required yard but must not encroach into the public right-of-way or required sidewalk. (e) Awning/Canopy. A wall-mounted, cantilevered structure providing shade and cover from the weather for a sidewalk. (i) An awning must be a minimum of ten feet clear height above the sidewalk and must have a minimum depth of six feet. (ii) An awning may extend into a required yard. (iii) An awning may encroach into the required sidewalk but may not encroach into the public right-of-way unless all applicable City regulations are met. (iv) Awning must be made of canvas and may not be reflective or shiny. (v) Awnings must have open ends called "shed awnings" to allow views into buildings. (vi) Awnings may not be internally lit. (vii) Awnings may not be narrower than nor two feet wider than the door or window opening that they serve. Where multiple doors and windows are less than two feet apart, multiple awnings may be combined into a single awning. (21) Fenestration. (a) Fenestration. (i) Fenestration is the minimum percentage of window and door glass area that must cover a façade. (ii) Glass used to satisfy fenestration requirements must be unpainted, must have a transparency (visible light transmission) higher than 70 percent, and must have an external reflectance of less than 15 percent. Transparency and external light reflectance must be established using the manufacturer's specifications. (iii) Fenestration is measured from the top of the finished floor to the top of the finished floor above. (iv) When there is no floor above, fenestration is measured from the top of the finished floor to the top of the wall plate. (v) Adhesive film, fabric, paper, and other materials affixed to the window surface or otherwise installed in a way that prevents visibility into the building interior are not allowed. This prohibition does not apply to curtains, shades, Venetian blinds, interior or exterior shutters, and other window treatments that are in operable condition and capable of being adjusted, opened, or closed daily. (b) Blank wall area. (i) Blank wall area means a portion of the exterior façade of the building that does not include fenestration. (ii) Blank wall area applies in a horizontal direction.

(Ord. No. 2020-49(20-O-1171), § 3(Att. C), 9-17-20)

Ask a question about Atlanta law

Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.