Sec. 18-63. - Design specifications.
(a) Roadways: (1) All base material for patches on city streets shall be six inches thick, Class A, 3,000 p.s.i. concrete. An allowance of 1½ inches in depth shall be provided for appropriate asphaltic overlays. (2) Asphalt will be 1½ inches, Type E mix unless a more suitable in-kind mix is specified for large cuts by the city engineer. (3) The entire base area shall be tack-coated prior to any placement of asphalt. (4) Patching will be permitted on days when weather is satisfactory. Placing concrete temperature shall be 35 degrees and rising, and placing asphalt temperature shall be 35 degrees and rising. (5) All trench cuts shall be a minimum of 18 inches wide to allow room for mechanical compaction equipment. All backfill shall be tamped in six-inch lifts, to a minimum of 95 percent maximum dry density of a standard proctor. (6) Ditches shall be cut an additional six inches wide on each side to a depth of 7½ inches to provide a concrete bridge to reduce differential settlement. (7) All cuts shall be made so as to maintain square or rectangular configurations. No round cuts will be accepted. (8) No cleated equipment is to be used on paved surfaces. Special care shall be taken to protect pavements from damage by equipment stabilizers. (9) All excavated material shall be cleaned from pavement surfaces to the satisfaction of the field inspector by an approved method. (10) Drawing Number E-905 shall be filed in the department of engineering for graphic details of patching specifications. (b) Driveways: (1) Residential driveways will be replaced with five-inch, Class A, 3,000 p.s.i. concrete. (2) Commercial driveways will be replaced with six-inch, Class A, 3,000 p.s.i. concrete. (3) Asphalt driveways will be sawed and replaced in a uniform manner. (4) All driveways must be replaced with special care taken to satisfy property owners. Breakout limits shall be determined by utilities. In cases of disputes with property owners, the decision of the city engineer shall be final.
(Ord. No. 82-98, 12-28-82)
Ask a question about Columbus law
Corpus searches the Columbus sections it holds and shows the ones that match, with their citations. Free, no sign-in.