§ 18-67 — Drawings and specifications
Code of Ordinances of the City of Kennesaw, Georgia (Codified through Ordinance No. 2026-06, enacted March 2, 2026. (Supp. No. 37)) · Kennesaw Municipal Code § 18-67
Corpus is an independent public-information project, not the official City of Kennesaw website. Stable reference: corpuslaw.us/code/316c00cb-3b74-48c4-b813-4cef5c41f665
Sec. 18-67. - Drawings and specifications.
(a) Requirements. When required by the building official, three or more copies of specifications, and of drawings drawn to scale with sufficient clarity and detail to indicate the nature and character of the work, and one digital copy of drawings and specifications shall accompany the application for a permit. Such drawings and specifications shall contain information, in the form of notes or otherwise, as to the quality of materials, where quality is essential to conformity with the technical codes. Such information shall be specific, and the technical codes shall not be cited as a whole or in part, nor shall the term "legal" or its equivalent be used as a substitute for specific information. All information, drawings, specifications and accompanying data required by the building official to be prepared by an architect or engineer shall be affixed with their official seal, name, and signature of the person responsible for the design. One copy of the specifications and drawings shall be in digital format acceptable to the building official. (b) Additional data. The building official may require details, computations, stress diagrams, and other data necessary to describe the construction or installation and the basis of calculations. All information, drawings, specifications and accompanying data required by the building official to be prepared by an architect or engineer shall be affixed with their official seal, name, and signature of the person responsible for the design. (c) Design professionals. The design professional shall be an architect or engineer legally registered under the laws of the State of Georgia regulating the practice of architecture or engineering and shall affix his official seal to such drawings, specifications and accompanying data, for the following: (1) All Group A, E and I occupancies, as determined and defined by the International Building Code. (2) Buildings and structures three stories or more in height. (3) Buildings and structures 3,000 square feet or more in area. For all other buildings and structures, the submittal shall bear the certification of the applicant that some specific state law exception permits its preparation by a person not so registered. (4) Any building, structure, or system as deemed necessary by the building official. (d) Structural and fire resistance integrity. Plans for all buildings shall indicate how required structural and fire resistance integrity will be maintained where a penetration of a required fire resistant wall, floor or partition will be made for electrical, gas, mechanical, plumbing and communication conduits, pipes and systems and also indicate in sufficient detail how the fire integrity will be maintained where required fire resistant floors intersect the exterior walls. (e) Site drawings. Drawings shall show the location of the proposed building or structure and of every existing building or structure on the site or lot. The building official may require a boundary line survey prepared by a state registered land surveyor. (f) Hazardous occupancies. The building official may require the following: (1) General site plan. A general site plan drawn at a legible scale which shall include, but not be limited to, the location of all buildings, exterior storage facilities, permanent access ways, evacuation routes, parking lots, internal roads, chemical loading areas, equipment cleaning areas, storm and sanitary sewer accesses, emergency equipment and classes and the maximum quantities per hazard class of hazardous materials stored. (2) Building floor plan. A building floor plan drawn to a legible scale which shall include, but not be limited to, all hazardous materials storage facilities within the building and shall indicate rooms, doorways, corridors, exits, fire rated assemblies with their hourly rating, location of liquid tight rooms and evacuation routes. Each hazardous material storage facility shall be identified on the plan with the hazard classes and quantity range per hazard class of the hazardous materials stored.
(Ord. No. 2006-06, § 1(18-35), 2-21-06)
Ask a question about Kennesaw law
Corpus searches the Kennesaw sections it holds and shows the ones that match, with their citations. Free, no sign-in.