4.15 - Architectural Standards

4.15.1 The following architectural standards shall apply to all buildings in areas regulated by this code. 4.15.2 Properties listed within a historic district are subject to the architectural requirements spelled out in the Historic Kennesaw Design Standards and are not subject to 4.15.3, 4.15.4, or 4.15.5. 4.15.3 General to Zones T3, T4, T5, and Special Districts a. Exterior materials for all buildings may be combined only horizontally, with the heavier below the lighter. 4.15.4 Specific to buildings with a Detached Single Family Home use in Zones T3, T4, T5, and Special Districts. a. Materials. i. The exterior finish material on all Facades shall be limited to brick, manufactured stone, natural stone, wood siding, and/or cementitious siding. ii. Foundations shall be constructed as a distinct building element that contrasts with Facade materials. Exposed above-ground foundations shall be coated or faced in brick, manufactured stone, or natural stone to contrast with façade materials. iii. Synthetic stucco exterior insulation finishing systems are prohibited. iv. Other materials not mentioned above will be reviewed by the plan review committee for appropriateness during the normal application process. If the plan review committee finds the material is inappropriate, the decision can be appealed through a variance process as described in Chapter 9 of the Unified Development Code. b. Windows and Doors along Frontages. i. Where used, shutters shall match one-half the width of the window opening to which they are adjacent. ii. Windows shall provide glass that is clear, unpainted, and not tinted so as to obstruct views into the building. iii. Doors and windows that operate as sliders are prohibited. iv. Windows shall be vertically shaped with a height greater than width. The top of said windows shall generally be in alignment with the top of the adjacent door frame. v. Windows shall have True or Simulated Divided Lights or be one-over-one lights. vi. Windows shall include sills of wood, masonry, stone, cast stone, or terra cotta. vii. Window frames shall be recessed a minimum of 1.5 inches from the exterior façade. c. Roofs. i. Pitched roofs are required and shall be symmetrically sloped no less than 6:12, except that roofs for porches and attached sheds may be no less than 2:12. ii. All roofs shall have a minimum 25-year roof life and no visible roll roofing. iii. Chimneys, where provided, shall extend to the ground and shall be faced in brick or stacked stone. Chimneys shall extend between 3 and 6 feet above the roof line. d. No more than three adjacent row house units shall have the same façade design. Differentiation between adjacent façades may be accomplished by a change in materials, building height, color, roof form or setbacks, provided that the appearance of a separate building is achieved. e. Stoops and porches: i. Porches and stoops along a Frontage shall not be enclosed with screen, wire, or glass. ii. Entry steps leading to porches and stoops along a Frontage shall have enclosed risers. 4.15.5 General to all other buildings in Zones T3, T4, T5, and Special Districts a. The design of buildings shall conform to Section 4.08.01 City-Wide Architectural Design Standards and to the requirements below. Where the standards do not agree, the standards below shall govern. b. Buildings less than 3,000 sf may elect to follow the standards of 4.15.4 or 4.15.5 c. Materials. i. The exterior finish material on all Facades shall be limited to brick, manufactured stone, natural stone, wood siding, and/or cementitious siding. ii. Synthetic stucco exterior insulation finishing systems, concrete masonry, and vinyl siding are prohibited as finish materials. iii. Other materials not mentioned above will be reviewed by the plan review committee for appropriateness during the normal application process. If the plan review committee finds the material is inappropriate, the decision can be appealed through a variance process as described in Chapter 9. iv. All four facades of the building must continue the design attributes and combination of materials. d. Windows and Doors along Frontages. i. Windows shall provide glass that is clear, unpainted, and not tinted so as to obstruct views into the building. ii. Doors and windows that operate as sliders are prohibited iii. Windows shall be vertically shaped with a height greater than width. The top of said windows shall generally be in alignment with the top of the adjacent door frame. iv. Not more than 20 feet of building frontage shall be provided without a door or window. e. Roofs. i. Pitched roofs, if provided, shall be symmetrically sloped no less than 6:12, except that roofs for porches and attached sheds may be no less than 2:12. ii. Flat roofs shall be enclosed by parapets a minimum of 42 inches high, or as required to conceal mechanical equipment.

(Ord. No. 2016-03, Att., 3-7-16)

Ask a question about Kennesaw law

Corpus searches the Kennesaw sections it holds and shows the ones that match, with their citations. Free, no sign-in.