For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4.5 — Building Form

Code of Ordinances of the City of Kennesaw, Georgia (Codified through Ordinance No. 2026-06, enacted March 2, 2026. (Supp. No. 37)) · Kennesaw Municipal Code, App. A, ch. 4, art. 4, § 4.5

Corpus is an independent public-information project, not the official City of Kennesaw website. Stable reference: corpuslaw.us/code/d33305b8-ca76-47f3-af68-2e92947c6b00

4.5 - Building Form

4.5.1 General to zones T3, T4, T5 a. The Private Frontage of buildings shall conform to Table 8: Private Frontages and Table 11: Code Summary. b. Buildings on corner Lots shall have two Private Frontages as shown in Table 14: Definitions Illustrated. Prescriptions for the Second and Third Layers pertain only to the Principal Frontage. Prescriptions for the First Layer pertain to both Frontages. c. Building heights and Setbacks shall conform to Table 6: Building Form. d. Stories may not exceed 14 feet in height from finished floor to finished ceiling, except for a first floor Commercial or Civic Function, which shall be a minimum of 11 feet with a maximum of 25 feet. A single floor level exceeding 14 feet, or 25 feet at ground level, shall be counted as two stories. Mezzanines extending beyond 33% of the floor area shall be counted as an additional Story. e. A first level Residential Function may be raised a maximum of 6 feet from average Sidewalk grade unless a greater height is approved by Variance. f. In a Parking Structure or garage, each above-ground level counts as a single Story regardless of its relationship to habitable Stories. g. Building height limits do not apply to attics, masts, belfries, clock towers, chimney flues, water tanks, or elevator bulkheads. Attics shall not exceed 14 feet in height. h. The habitable area of an Accessory Unit within a Principal Building or an Outbuilding shall not exceed 440 square feet, excluding the parking area. 4.5.2 Specific to zone T3 a. No portion of the Private Frontage may Encroach the Sidewalk. b. Open porches may Encroach the First Layer for 50% of the layer's depth. c. Balconies and bay windows may Encroach the First Layer for 25% of the layer's depth except that balconies on porch roofs may Encroach as does the porch. 4.5.3 Specific to zone T4 a. Balconies, open porches and bay windows may Encroach the First Layer for 50% of the layer's depth. 4.5.4 Specific to zones T5 a. Except where prohibited, Awnings, Arcades, and Galleries may Encroach the Sidewalk to within 2 feet of the Curb but must clear the Sidewalk vertically by at least 8 feet. b. Stoops, Lightwells, balconies, bay windows, and terraces may Encroach the First Layer for 100% of the layer's depth. c. A walkway with a minimum width of 4 feet shall connect rear buildings to the public Sidewalk. d. A first level Residential or Lodging Function shall be raised a minimum of 2 feet from average Sidewalk grade unless a lesser height is necessary to allow wheelchair access. 4.5.5 Specific to Special Districts a. A walkway with a minimum width of 5 feet shall connect all buildings to the public Sidewalk.

(Ord. No. 2016-03, Att., 3-7-16)

Ask a question about Kennesaw law

Corpus searches the Kennesaw sections it holds and shows the ones that match, with their citations. Free, no sign-in.