§ 10.5.2 — General Standards
Code of Ordinances of the City of Roswell, Georgia (Codified through Ordinance No. 2025-11-10, adopted November 10, 2025. (Supp. No. 17)) · Roswell Unified Development Code § 10.5.2
Corpus is an independent public-information project, not the official City of Roswell website. Stable reference: corpuslaw.us/code/88a2c2cf-0ec7-4c2f-95c7-361197e48f9e
10.5.2. - General Standards
A. Retaining walls must be constructed of high quality materials; material approval shall be subject to approval by the Design Review Board or Historic Preservation Commission, as applicable. B. When finished grades are proposed to be steeper than 2:1 (one vertical foot of rise for every two feet of horizontal displacement) an appropriate retaining structure shall be designed to reinforce or retain the resulting embankment. C. All retaining walls equal to or greater than 8 feet shall be designed by a qualified registered professional engineer. All proposed retaining walls equal to or greater than 6 feet in height will be subject to review and approval by the Mayor and City Council. Retaining walls that are not in substantial accordance with a previously approved site plan, as defined in Article 13, will be also subject to review and approval by the Mayor and City Council. D. Stepped retaining walls shall have the upper wall setback a minimum distance of 1.5 times the height of the tallest wall or as approved by the City Engineer, with review by the Community Development and Transportation Committee. E. All structural components of the wall shall meet the minimum building codes for the proposed use. F. Wall design will consider foundation drainage and select backfill material for the proposed conditions. G. Walls shall be located in such a fashion as to not encroach upon existing or proposed drainage easements, drainage courses or floodplains or to encumber the natural flow of surface runoff of stormwater. Walls shall be located at a distance from such watercourses to allow for anticipated future maintenance of the easement. H. Retaining walls that are proposed for the purpose of stormwater detention/retention must be designed to demonstrate that the walls are capable of a hydrostatic load. I. Where stormwater detention/retention walls are exposed equal to or greater than 6 feet they are required to be faced with stone, brick or decorative concrete modular block, as approved, modified, or denied by the Design Review Board and/or the Historic Preservation Commission, as applicable. J. The maximum length of continuous, unbroken and uninterrupted retaining wall equal to or greater than 6 feet in height is 100 feet. For walls greater than 100 feet in length, breaks must be provided through the use of columns or change in material. K. Retaining walls equal to or greater than 6 feet in height shall be screened with landscaping, as approved by the Design Review Board or Historic Preservation.
Ask a question about Roswell law
Corpus searches the Roswell sections it holds and shows the ones that match, with their citations. Free, no sign-in.
