§ 6.1.3 — Height and Mass
Code of Ordinances of the City of Sandy Springs, Georgia (Codified through Ordinance No. 2026-03-006, enacted March 17, 2026 (Supp. No. 24)) · Sandy Springs Development Code § 6.1.3
Corpus is an independent public-information project, not the official City of Sandy Springs website. Stable reference: corpuslaw.us/code/e8e67f33-6393-4acd-9a3d-238d89f8c595
Sec. 6.1.3. - Height and Mass
A. Building Height 1. Building height is measured in both stories and feet from average grade to the average height level between the eaves and ridge of a pitched roof, or to the highest point of the roof deck of a flat roof. A maximum 6-foot height encroachment for a parapet wall is allowed. [image omitted; see the official code] 2. An attic in a pitched roof form does not count as a story where 50% or more of the attic floor area has a clear height of less than 7.5 feet; measured from the finished floor to the finished ceiling. [image omitted; see the official code] 3. Basements and mezzanines, as defined in the Building Code, do not count as a story. Mezzanines can be counted to meet district height minimums, however (See Sec. 6.1.3 B.1 below). 4. For all buildings with a build-to-zone requirement and all single unit detached, the average grade is determined by calculating the average of the highest and lowest elevation of the finished grade measured along the front of the building parallel to the primary street setback. For all other buildings, the average grade is determined by calculating the average of the highest and lowest elevation of the finished grade measured around the entire perimeter of the building. This applies to building in districts that do not have build-to-zones, when a required frontage overrides the build-to-zone requirement, and for buildings where no part of the building is within the build-to-zone. [image omitted; see the official code] 5. For all single unit detached and single unit attached units, where a lot slopes downward from the front property line, only 1 story in addition to the specified maximum number of stories may be built on the lower, rear portion of the lot. [image omitted; see the official code] 6. For any building type other than residential single unit detached or attached, there is no restriction on the number of stories added on a lower, rear portion of a lot. This also applies to developments where the lower, rear portion of the lot abuts a new street required by the Development Code. When a new street is required, 2 additional stories may be constructed along the new street in the rear portion of the lot. However, any additional buildings fronting on the new street are required to meet the story maximum for the district. [image omitted; see the official code] 7. A story is considered that portion of a building included between the upper surface of any floor and the upper surface of the floor next above, except that the topmost story means that portion of a building included between the upper surface of the topmost floor and the ceiling or roof above. B. Minimum Height 1. Where a minimum height of 2 or more stories is required, each required story must contain habitable space for at least 50% of the floor. A mezzanine can be used in lieu of a second floor upon request at the Director's discretion. 2. The Director may allow the following buildings to be exempt from minimum height requirements: a. Buildings internal to a site not directly serviced by on-site parking or a drive-through, such as a jewel box building or kiosk, so long as it is integrated into the overall site plan. b. Buildings with a footprint of 2,000 square feet or less. c. Buildings with single unit detached, single unit attached, or neighborhood unit uses. [image omitted; see the official code] C. Height Encroachment Any height encroachment not specifically listed below is expressly prohibited, except where the Director determines that the encroachment is similar to a permitted encroachment listed below. 1. The maximum height limits of the district do not apply to a spire, belfry, cupola, dome, or other similar feature that does not contain a habitable space, or public utility facilities which by design or function must exceed the established height limits. 2. The following accessory structures may exceed the established height of the district, provided they do not exceed the maximum height by more than 6 feet: a. Chimney, flue or vent stack; b. Rooftop deck, patio; c. Flagpole; d. Landscaping; e. Skylights; f. Parapet wall; and g. Solar panels, wind turbines and rainwater collection systems. 3. The following accessory structures may exceed the established height, provided they do not exceed the maximum height by more than 18 feet, do not occupy more than 50% of the roof area: a. Cabana, pool house, rooftop restaurant, or other amenity; b. Pergola, trellis, gazebo, or other similar minor structure architecturally integrated with the building; c. Elevator or stairway access to the roof; and d. Mechanical equipment. D. Ground Floor Elevation 1. Ground floor elevation is measured from the top of the adjacent curb, or from the crown of the road where no curb exists, to the top of the finished ground floor at the building main entrance. [image omitted; see the official code] 2. Minimum ground floor elevation applies to the first 30 feet of the lot depth measured from the right-of-way. 3. The Director may provide relief to the extent necessary from the maximum ground floor elevation requirements on sites with significant topography. E. Story Height Story height is the height of each story of building, measured from the top of the finished floor to the top of the finished floor above. When there is no floor above, story height is measured from the top of the finished floor to the top of the wall plate above. [image omitted; see the official code] F. Building Mass 1. Street-Facing Building Length Street-facing building length is the maximum length of a building or structure facing a public or private street, and located within the build-to zone. 2. Building Break Allowance Buildings that meet 1 of the following standards, the Director may allow the maximum street facing-building length to be exceeded. a. When a continuous structure provides an open space meeting the following requirements, the portions of the building on each side of the open space may be considered as a separate building: i. One building break per street-facing façade is allowed; ii. The open space must meet the requirements of Pedestrian Amenity Space; iii. The building break width must be at least ¼ the width of the widest adjacent street-facing building length; and iv. The building break depth must be at least equal to the width of the open space or 20 feet, whichever is less. b. When a continuous structure provides an articulation to the building façade that meets the following requirements, each façade articulation may be considered as a separate building: i. Two portions of the street-facing building façade must have a variation in setback of at least 4 feet. The combined length of the setbacks must total no less than 25% of the length of the building. ii. Contrasting colors or material is used on the primary façade and the abutting façade setback to emphasize the articulation and variation along the street-facing building façade.
(Ord. No. 2023-12-22, § I(Att. A), 12-5-2023; Ord. No. 2025-09-22, § I, 9-16-2025)
Ask a question about Sandy Springs law
Corpus searches the Sandy Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.