§ 8-7045 — General standards
Code of Ordinances of the City of Savannah, Georgia (Division II) (enCodePlus online edition as published 2026-11-20) · Savannah Code of Ordinances, pt. 8, ch. 7., art. D, § 8-7045
Corpus is an independent public-information project, not the official City of Savannah website. Stable reference: corpuslaw.us/code/dd8febd0-1195-4891-8ce2-6b6a9c6ccb01
Sec. 8-7045. - General standards.
In all areas of special flood hazard and also including those areas known to have flooded historically or defined through hydraulic modeling or other standard engineering analysis by governmental agencies or private parties but not yet incorporated in an FIS, the following provisions are required: (1) 1. Anchors. New construction and substantial improvements of existing structures shall be anchored to prevent flotation, collapse or lateral movement of the structure; (2) 2. Materials; utility equipment. New construction and substantial improvements of existing structures shall be constructed with materials and utility equipment resistant to flood damage; (3) 3. Methods; practices. New construction or substantial improvements of existing structures shall be constructed by methods and practices that minimize flood damage; (4) 4. Elevated buildings. All new construction or substantial improvements of existing structures that include any fully enclosed area located below the lowest floor formed by foundation and other exterior walls shall be designed so as to be an unfinished or flood resistant enclosure. The enclosure shall be designed to equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwater. (Not applicable in coastal high hazard areas). (a) a. Designs for complying with this requirement must either be certified by a professional engineer or architect or meet the following minimum criteria: (i) i. Provide a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; (ii) ii. The bottom of all openings shall be no higher than one foot above grade; and, (iii) iii. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwater in both directions. (b) b. So as not to violate the "lowest-floor" criteria of this chapter, the unfinished or flood-resistant enclosure shall only be used for parking of vehicles, limited storage of maintenance equipment used in connection with the premises, or entry to the elevated area. (c) c. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. (5) 5. All heating and air conditioning equipment and components (including ductwork), all electrical (except the main disconnect, the electric meter, and one ground fault interrupted outlet and switch), ventilation, plumbing fixtures, and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. (6) 6. Manufactured homes shall be anchored to prevent flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable State requirements for resisting wind forces. (7) 7. New and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system; (8) 8. New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into flood waters; (9) 9. On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding, and; (10) 10. Any alteration, repair, reconstruction or improvement to a structure, which is not compliant with the provisions of this chapter, shall be undertaken only if the non-conformity is not furthered, extended or replaced. (11) 11. The Special Flood Hazard Area (SFHA) Permit applicant must sign and record a "Non-conversion Agreement" for certain structures in the floodplain as provided by the city engineer. The agreement must state that areas located below the design flood elevation (DFE) shall not be converted to habitable space and must allow the development services director/city engineer access to ensure the area is not in violation of this ordinance. The owner must record the agreement with the deed for future owners' reference. (12) 12. Any structures utilizing floodproofing measures must submit an operations and maintenance plan to ensure continued viability of the floodproofing measures.
(Ord. of 10-24-2024(21), § 1) (Ord. of 9-25-2008, art. 4, § A;)
Ask a question about Savannah law
Corpus searches the Savannah sections it holds and shows the ones that match, with their citations. Free, no sign-in.
