§ 8-7049 — Standards for areas of shallow flooding (AO zones)
Code of Ordinances of the City of Savannah, Georgia (Division II) (enCodePlus online edition as published 2026-11-20) · Savannah Code of Ordinances, pt. 8, ch. 7., art. D, § 8-7049
Corpus is an independent public-information project, not the official City of Savannah website. Stable reference: corpuslaw.us/code/e3a78861-c605-4e13-9bf3-7ba2871530a9
Sec. 8-7049. - Standards for areas of shallow flooding (AO zones).
Areas of special flood hazard established in section 8-7011 may include designated "AO" shallow flooding areas. These areas have base flood depths of one to three feet above ground, with no clearly defined channel. The following provisions apply: (1) 1. All new construction and substantial improvements of residential and non-residential structures shall have the lowest floor, including basement, elevated to the flood depth number specified on the flood insurance rate map (FIRM), above the highest adjacent grade. If no flood depth number is specified, the lowest floor, including basement, shall be elevated at least four feet above the highest adjacent grade. Openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of subsection 8-7045(4), "Elevated buildings". The development services director shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file. (2) 2. New construction or the substantial improvement of a nonresidential structure may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be water tight to the specified FIRM flood level plus two feet, above highest adjacent grade, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the official as set forth above and as required in subsections 8-7031(1) and (2). (3) 3. Drainage paths shall be provided to guide floodwater around and away from any proposed structure.
(Ord. of 10-24-2024(21), § 1) (Ord. of 9-25-2008, art. 4, § E;)
Ask a question about Savannah law
Corpus searches the Savannah sections it holds and shows the ones that match, with their citations. Free, no sign-in.