§ 7-379 — Definitions
Code of Ordinances of the City of Cedar Falls, Iowa (Codified through Ordinance No. 3140, enacted March 16, 2026. (Supp. No. 27)) · Cedar Falls Code of Ordinances § 7-379
Corpus is an independent public-information project, not the official City of Cedar Falls website. Stable reference: corpuslaw.us/code/aa25d509-ea11-4ae0-8254-30272a6a1196
Sec. 7-379. - Definitions.
The following words, terms and phrases, when used in this article, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: Administrative authority means for the purpose of this section, the administrative authority shall be the board of trustees of the municipal water utility of the city, for backflow prevention assemblies for containment, and the city council of the city, for backflow prevention by isolation, acting through such persons or agencies they shall designate. Air gap water distribution means an air gap water distribution is the unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet conveying potable water to the flood level rim of any tank, vat, or fixture. Approved backflow prevention assembly for containment means a backflow prevention assembly which is listed by the University of Southern California-Foundation for Cross Connection Control and Hydraulic Research as having met the requirements of ANSI-AWWA standard C510, current revision, "Double Check Valve Backflow Prevention Assemblies", or ANSI-AWWA Standard C511, current revision, "Reduced Pressure Principle Backflow Prevention Assemblies" for containment. The listing shall include the limitations of use based on the degree of hazard. The backflow prevention assembly must also be listed by the International Association of Plumbing and Mechanical Officials. Approved backflow prevention assembly for containment in a fire protection system means a backflow prevention assembly to be used in a fire protection system which meets the requirements of Factory Mutual Research Corporation (FM) and Underwriters Laboratory (UL), and the requirement of the fire code and the building code of the city, in addition to the requirements in the definition of the term "approved backflow prevention assembly for containment." Devices sized smaller than 2½ inches which have not been listed by Underwriters Laboratory (UL) and tested by Factory Mutual Research Corporation (FM) may be allowed if they meet the requirements of the fire code and the building code of the city. Auxiliary water supply means any water supply on or available to the premises other than the water purveyors approved public water supply such as, but not limited to a private well, pond, or river. Containment means a method of backflow prevention which requires the installation of a backflow prevention assembly at the water service entrance. Contamination means an impairment of the quality of the potable water which creates an actual hazard to the public health through poisoning or through the spread of disease by sewage, industrial fluids, or waste, also defined as high hazard. Cross connection means any actual or potential connection or arrangement, physical or otherwise, between a potable water supply system and any plumbing fixture or tank, receptacle, equipment, or device, through which it may be possible for nonpotable, used, unclean, polluted, and contaminated water, or other substance, to enter into any part of such potable water system under any condition. Customer means the owner, operator, or occupant of a building or property which has a water service from a public water system, or the owner or operator of a private water system which has a water service from a public water system. Degree of hazard means the rating of a cross connection or water service which indicates if it has the potential to cause contamination or pollution. Double check valve backflow prevention assembly means a backflow prevention device consisting of two independently acting internally loaded check valves, four properly located test cocks and two isolation valves. High hazard cross connections means a cross connection which may cause an impairment of the quality of the potable water by creating an actual hazard to the public health, through poisoning or through the spread of disease by sewage, industrial fluids, or waste. Isolation means a method of backflow prevention in which a backflow prevention assembly is located at the cross-connection rather than at the water service entrance. Low hazard cross connection means a cross connection which may cause an impairment of the quality of potable water to a degree which does adversely and unreasonably affect the aesthetic qualities of such potable waters for domestic use. Multiple family residential units means a building designed to be used as residential occupancy for three or more dwelling units, each having separate plumbing facilities. Pollution means an impairment of the quality of the potable water to a degree which does not create a hazard to the public health but which does adversely and unreasonably affect the aesthetic qualities of such potable waters for domestic use. The term "pollution" is defined as low hazard. Potable water means water which is satisfactory for drinking, culinary, and domestic purposes, and meets the requirements of the health authority having jurisdiction. Privately owned customer water system piping means water service line pipes and plumbing fixtures connected to the public water system of the city which are extended to the customer's property and into the customer's building for service to the customer and are regulatory controlled by which is defined in the city. Reduced pressure principle backflow prevention assembly means a backflow prevention device consisting of two independently acting internally loaded check valves, a different pressure relief valve, four properly located test cocks, and two isolation valves. Registered backflow prevention assembly technician means a person who is registered by the state of to test or repair backflow prevention assemblies and report on the condition of those assemblies. Single-unit dwelling means a structure containing one dwelling unit. Thermal expansion means volumetric increase of water due to heating resulting in increased pressure in a closed system. Water service means depending on the context, water service is the physical connection between a public water system and, a customer's building, property, or private water system or the act of providing potable water to a customer.
(Code 2017, § 7-501; Ord. No. 2196, § 1, 6-23-1997)
Ask a question about Cedar Falls law
Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.
