§ 12.25 — Water Meters
Cedar Rapids, Iowa, Municipal Code (Supp. No. 25, Update 1: codified through Ordinance No. 025-26, passed July 28, 2026) · Cedar Rapids Municipal Code § 12.25
Corpus is an independent public-information project, not the official City of Cedar Rapids website. Stable reference: corpuslaw.us/code/630fc8ef-3150-4fd1-b8e2-517cb4ca0364
12.25 - Water Meters.
All water furnished to a property shall be metered. Meters shall be purchased from and set by the Water Division. Owners must provide suitable location in their piping system to install an outside reading device for the meter. All new water meter settings shall be installed with an outside reading device. Meters shall be placed on service pipe no more than 2 feet from the location in the wall or floor where such pipe enters the premises. If a physical premises does not exist, the location and piping configuration must be approved by the Water Division prior to installation. The piping system shall be so constructed, and meters so placed that all water to be used in or about the premises shall pass through the water meter, and the owner of the premises shall be responsible for compliance with this provision, and liable for the payment for water used in violation of this provision. Separate meters may be purchased from and set by the Utilities Department - Water Division for purposes of lawn watering or irrigation. There shall be suitable place provided for the meter so as to keep it dry, warm, clean, and readily accessible at all times to meter readers and service representatives of the Water Division. All valves and fittings necessary to comply with these requirements and provide connection to the meter, except a coupling or flange at each end of meter, shall be provided and maintained by the owner of the premises to be served. For services larger than 2 inches in diameter, the Water Division reserves the right to require installation of two or more meters of smaller size. Each meter shall have a valve or shut-off on both inlet and outlet pipes in addition to the basement shut-off. Where a service pipe large than 2 inches in diameter is used, the plumber shall call the Water Division office for instructions regarding the fitting and space to be provided for the water meters. The owner is responsible for plumbing changes required to accommodate the meter specified by the Water Division. In case two or more meters are desired for measuring water to different tenants in the same building from one service connection, they shall be so placed that no one of them shall measure water which has passed through another one. Multiple meter settings. Every meter will be assigned to an account holder by the Water Division. Each meter must be valved such that service through a meter can be shut off and the meter removed without interrupting service to other account holders served through other meters within a property. Where multiple meters are provided for multiple account holders within a property, the meters shall be placed in a common meter room with either individual stop boxes for each unit or keyless entry to the central location. The two options available for metering to multiple units on a single property are as follows. In either case a master stop box must be provided as illustrated in figures in Division 5 - Water Mains and Appurtenances of the Cedar Rapids Supplement to SUDAS. See Section 12.12 for restrictions on common service line arrangements to multiple properties. Option 1: One meter for each unit served within a common meter room accessible to Water Division personnel at any time. Where there is a manifold for multiple meters, there must be a meter installed at each opening before service can be initiated for any unit. This common meter room must be accessible with keyless entry provided for outside access or inside a common area provided that no keys are required. Door locks on the room must be of a coded alphanumeric design and the access code provided to the Water Division. The property owner will be subject to a fine, termination of services, and a lien on the property for noncompliance of keyless entry requirement. See Division 5 - Water Mains and Appurtenances in the Cedar Rapids Supplement to SUDAS. Option 2: One meter within each unit with individual stop boxes provided in a manifold arrangement exterior to the building, or an individual stop box provided directly exterior to each unit. The property owner will be subject to a fine for failure to repair inoperable stop box if not repaired within 10 days from date of notice provided by the Water Division and subject to service termination until the repair is complete. Meters must be verified by the property owner as to the unit being served and marked accordingly. The meters must be tagged with a permanently attached hang tag or the equivalent to identify each unit served. The property owner will be charged on a time and material basis when the Water Division needs to verify which meters service which units. Outside reading devices. The Water Division will install the outside reading device. The location of the outside reading device shall be determined by the Water Division. There shall be conduit with a minimum size of 3/4 inch installed on all new and remodeled properties. The conduit must run from the closest point of the water meter (minimum of 6 feet) to a point of the exterior of the property either in the back or side of the building and be a minimum of 60 inches from the ground. Commercial properties or multi-unit properties must install conduit with a minimum size of 1 inch on all new and remodeled properties. A 1-inch conduit is required for each set of eight meters at multi-unit properties. (025-24)
Ask a question about Cedar Rapids law
Corpus searches the Cedar Rapids sections it holds and shows the ones that match, with their citations. Free, no sign-in.