Sec. 14-155. - Building standards and inspections.

(a) Before any alteration, modification or construction occurs to any structure pursuant to this article, a building permit shall be obtained as required under section 26-113 of the building code. (b) The operator, organizer or owner of any amusement house shall permit entry to any city inspector for purposes of determining compliance with this article and all other applicable statutes and ordinances. (c) Special exit requirements shall be as follows: (1) An amusement house using the maze concept shall have no dead-end paths and shall have an exit path out of the maze for approximately every 50 feet of linear travel. All doors out of the maze shall not be provided with locks or latches, unless panic hardware is installed. (2) In the maze and throughout the amusement building, where the maze is located, exit signs shall be installed to mark changes in direction to readily distinguish exits and exit paths and at all required exit doorways. Exit illumination and exit signs shall conform with the requirements of sections 3313 and 3314(b), (c), (d), respectively, of the Uniform Building Code, except that exit illumination must be provided capable of illuminating all exits, exitways, stairways, corridors and mazes with light having an intensity of not less than one footcandle at the floor level. Illumination for the exit signs and exit illumination shall be required only under emergency conditions in accordance with section 14-156(c) of this article. (3) Amusement houses shall not be located above the first story and shall be provided with a sufficient number of exits in relation to floor area and occupant load as determined by the city building code. In no case may such area be used unless provided with at least two exits, the location of which are in compliance with section 3303(c) of the Uniform Building Code. (d) A public address system, which may also serve as the signaling devices of the fire alarm system, shall be provided and shall be audible throughout the entire amusement house. (e) Occupancy requirements shall be as follows: (1) The total number of persons within a facility at any given time shall be limited to an exit capacity to be determined by the fire chief and building official upon inspection of the facility, such occupancy load to be posted at the entry to the amusement house in compliance with section 26-33 of this Code. (2) Toilet facilities shall be provided in sufficient number according to attendance estimates as required, but in no instance less than four. (3) Any child or group of children 12 years old or under shall be accompanied by an adult, that is, a person 18 years of age or older. Any such single group shall not exceed ten in number. (4) Every guide and scene character shall have an operable flashlight powered by a minimum of two C-celled batteries and shall be completely familiar with all aspects of the facility, inclusive of but not limited to operation of fire emergency equipment and locations of exits.

(C85, § 6-99; O.11,393, 11,526; C91, § 6-99; O.13,011)

Ask a question about Des Moines law

Corpus searches the Des Moines sections it holds and shows the ones that match, with their citations. Free, no sign-in.