Delete section R403.1.1 and insert in lieu thereof the following new section: R403.1.1 Minimum Footing Size. The minimum width for all footings shall be 16 inches. The footing width shall be based on the load-bearing value of the soil in accordance with Table R401.4.1. Footing projections, P, shall be not less than 2 inches (51 mm) and shall not exceed the thickness of the footing. Footing thickness and projection for fireplaces shall be in accordance with Section R1001.2. The size of footings supporting piers and columns shall be based on the tributary load and allowable soil pressure in accordance with Table R401.4.1. Footings for wood foundations shall be in accordance with the details set forth in Section R403.2, and Figures R403.1(2) and R403.1(3). Footings for precast foundations shall be in accordance with the details set forth in Section R403.4, Table R403.4, and Figures R403.4(1) and R403.4(2). Residential conventional footings are allowed in Table 403.5 based on the following dimensions and soil bearing pressure. Exception: Detached accessory structures are not required to have minimum 16 inch wide footings. Table 403.5 Residential Conventional Footing Dimensions Soil Bearing Pressure (pounds per square foot) | Conventional Footing Dimension | Required Reinforcement a, b (All reinforcing bars shall [be 40,000 psi]) Thickness (inches) | Width (inches) 2,000 psf | 8 | 16 | 2 - #4 bars 1,850 psf | 9 | 20 | 2 - #4 bars 1,500 psf | 10 | 20 | 2 - #5 bars 1,250 psf | 11 | 28 | 3 - #5 bars 1,000 psf | 12 | 32 | 3 - #5 bars a The minimum yield strength of reinforcing steel shall be 40,000 psi. b All reinforcement shall be installed in the middle third of the footing and in accordance with R4031.3.5.3. c Residential conventional footings shown in Table 403.5 are only allowed for conventionally designed one- or two-family dwelling structures not exceeding two stories in height, intended to be constructed on undisturbed, non-expansive soils. Townhouse structures are not allowed to utilize this table.
(O.15,861)
Ask a question about Des Moines law
Corpus searches the Des Moines sections it holds and shows the ones that match, with their citations. Free, no sign-in.