Sec. 26-310.7. - Floor elevations at other exterior doors.

Delete the section R318.3.2 and insert in lieu thereof the following new section. R318.3.2 Floor elevations at other exterior doors. Doors other than the required egress door shall be provided with landings or floors not more than 7-¾ inches (196 mm) below the top of the threshold. Exception: A top landing is not required where a stairway of not more than four risers is located on the exterior side of the door, provided that the door does not swing over the stairway.

(O.15,861, 16,520)