Sec. 26-804. - Design.
(a) Generally. General requirements for signs and sign structures shall be as follows: (1) Signs and sign structures shall be designed and constructed to resist wind and forces as specified in this section. All bracing systems shall be designed and constructed to transfer lateral forces to the foundations. For signs on buildings the dead and lateral loads shall be transmitted through the structural frame of the building to the ground in such manner as not to overstress any of the elements thereof. (2) The overturning moment produced from lateral forces shall in no case exceed two-thirds of the dead load resisting moment. Uplift due to overturning shall be adequately resisted by proper anchorage to the ground or to the structural frame of the building. The weight of earth superimposed over footings may be used in determining the dead load resisting moment. Such earth shall be carefully placed and thoroughly compacted. (b) Wind loads. Wind loads shall comply with the following: (1) Signs and sign structures shall be designed and constructed to resist wind forces as specified in the International Building Code. (2) In the absence of plans certified by an engineer registered in this state, simple pole or ground sign supports shall provide a section-modulus at the point of maximum bending equal to or greater than that obtained from the following formula: S.M. - 0.0004615 × (AS) × (PW) × (HC) Where: S.M. = Section modulus. AS = Area of sign face in square feet. PW = Pressure of wind in pounds per square feet as determined from the building code HC = Height of in feet of centroid of sign area from point of maximum bending (c) Combined loads. Vertical design loads, except roof live loads, shall be assumed to be acting simultaneously with the wind loads. (d) Allowable stresses. Allowable stresses shall be as follows: (1) The design of wood, concrete, steel or aluminum members shall conform to the requirements of the International Building Code. Loads, both vertical and horizontal, exerted on the soil, shall not produce stresses exceeding those specified in the building code. (2) The working stresses of wire rope and its fastenings shall not exceed 25 percent of the ultimate strength of the rope or fasteners. (3) Working stresses for wind loads combined with dead loads may be increased as specified in the building code.
(O.15,545)
Ask a question about Des Moines law
Corpus searches the Des Moines sections it holds and shows the ones that match, with their citations. Free, no sign-in.