Sec. 26-805. - Construction.

(a) Generally. The supports for all signs or sign structures shall be placed in or upon private property and shall be securely built, constructed, and erected in conformance with the requirements of the International Building Code. (b) Materials. Materials of construction shall be as follows: (1) Materials of construction for signs and sign structures shall be of the quality and grade as specified for buildings in the International Building Code. (2) In all signs and sign structures, the materials and details of construction shall, in the absence of specified requirements conform with the following: a. Structural steel shall be of such quality as to conform with the International Building Code. Secondary members in contact with or directly supporting the display surface may be formed of light gauge steel, provided such members are designed in accordance with the specifications of the design of light gauge steel as specified in the International Building Code and, in addition, shall be galvanized. Secondary members, when formed integrally with the display surface shall be not less than no. 24 gauge in thickness. When not formed integrally with the display surface, the minimum thickness of the secondary members shall be no. 12 gauge. The minimum thickness of hot-rolled steel members furnishing structural support for signs shall be one-fourth inch, except that if galvanized such members shall be not less than one-eighth inch thick. Steel pipes shall be of such quality as to conform with International Building Code. Steel members may be connected with one galvanized bolt provided the connection is adequate to transfer the stresses in the members. b. Anchors and supports when made of wood and embedded in the soil or within six inches of the soil shall be of all heartwood of a durable species or shall be pressure treated with an approved preservative. Such members shall be marked or branded by an approved agency. (c) Restriction on combustible materials. (1) All signs and structures erected in fire zone no. 1 shall have structural members of noncombustible materials. Ground signs may be constructed of any material meeting the requirements of the International Building Code, except as provided in subsection (b) of this section. (2) Roof signs, wall signs, projecting signs, and signs on marquees shall be constructed of noncombustible materials, except as provided in subsection (d) of this section. No combustible materials other than approved plastics shall be used in the construction of electric signs. (d) Nonstructural trim. Nonstructural trim and portable display surfaces may be of wood, metal, approved plastics, or any combination thereof. (e) Anchorage. (1) Members supporting unbraced signs shall be so proportioned that the bearing loads imposed on the soil in either direction, horizontal or vertical, shall not exceed the safe values. Braced ground signs shall be anchored to resist the specified wind load acting in any direction. Anchors and supports shall be designed for safe bearing loads on the soil and for an effective resistance to overturning. Anchors and supports shall penetrate to a depth below ground greater than that of the frostline. Portable ground signs supported by frames or posts rigidly attached to the base shall be so proportioned that the weight and size of the base will be adequate to resist the wind pressure specified in the International Building Code. Signs attached to masonry, concrete, or steel shall be safely and securely fastened thereto by means of metal anchors, bolts, or approved expansion screws of sufficient size and anchorage to support safely the loads applied. (2) No wooden blocks or plugs or anchors with wood used in connection with screws or nails shall be considered proper anchorage, except for signs attached to wood framing. (3) No anchor or support of any sign shall be connected to or supported by an unbraced parapet wall, unless such wall is designed in accordance with the requirements for parapet walls specified in Chapter 16 of the International Building Code. (4) Adjustable turnbuckles shall be safely secured to prevent movement. (f) Display surfaces. Display surfaces in all types of signs may be made of metal, glass, or approved plastics, except that glass shall not be used in any pole or projecting signs. Glass thickness and area limitations shall be as set forth in table no. 4-A in this section. Sections of approved plastics on wall signs shall not exceed 150 square feet in area. Exceptions: (1) In fire zone no. 3 the area may be increased by 50 percent. (2) Sections of approved plastics on signs other than wall signs may be of unlimited area if approved by the building official. TABLE NO. 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS Maximum Size of Exposed Glass Panel | Minimum Thickness of Glass (in inches) | Type of Glass Any Dimension (in inches) | Area (in square inches) 30 | 500 | ⅛ | Plain, plate or wired glass 45 | 700 | 3/16 | Plain, plate or wired glass 144 | 3,600 | ¼ | Plain, plate or wired glass Over 144 | Over 3,600 | ¼ | Wired glass (g) Approved plastics. The zoning enforcement officer shall require that sufficient technical data be submitted to substantiate the proposed use of any plastic material and, if it is determined that the evidence submitted is satisfactory for the use intended, he or she may approve its use. (h) Concealment of structural framework. No structural framework of any sign shall be covered or concealed. (i) Electrical wiring. All signs containing electrical wiring shall be subject to all provisions of the electrical code. (j) Maintenance and repair. All signs, together with all of their supports, braces, guys, and anchors, shall be kept in repair and in a proper state of preservation. The display surfaces of all signs shall be kept neatly painted or posted at all times. (k) Name of erector and date of erection. Every general advertising sign, as defined in chapter 134 of the City Code, and every sign which projects over any public right-of-way erected after January 1, 1966, shall have painted or otherwise attached on the exterior of the sign the name of the sign erector and date of erection. Such name and date shall be of sufficient size and contrast to be easily read from a reasonable distance.

(O.15,545, 15,819)

Ask a question about Des Moines law

Corpus searches the Des Moines sections it holds and shows the ones that match, with their citations. Free, no sign-in.