Sec. 46-555. - Exits.
Exits shall comply with chapter 10 of the International Fire Code and be as remote from each other as practical and shall be provided as follows: Occupant Load | Minimum Number of Exits 1 to 500 | 2 501 to 1,000 | 3 1,001 or 1,500 | 4 Each additional 500 persons | 36 additional inches of exit width (1) Width. The aggregate clear width of exits shall be a minimum of 36 inches wide (914 mm) for each 500 persons to be accommodated. (2) Signs. Exits shall be identified with signs that read "EXIT." The signs shall be weather-resistant with lettering on a contrasting background. The lettering shall be of sufficient height and brush stroke to be immediately visible from 75 feet (22,860 mm). Placement of the exit signs shall be approved by the fire code official.
(O.15,546, 16,318, 16,521)