§ 46-556 — Concession stands, food booths, and retail booths
Municipal Code of the City of Des Moines, Iowa (Supp. No. 38, Update 3: codified through Ordinance No. 16,577, adopted August 24, 2026) · Des Moines Municipal Code § 46-556
Corpus is an independent public-information project, not the official City of Des Moines website. Stable reference: corpuslaw.us/code/cee23334-c668-4762-b546-45773ebd6a35
Sec. 46-556. - Concession stands, food booths, and retail booths.
(a) General. Concession stands, food booths, and retail booths shall be in accordance with section 3108. (1) Distances. A minimum of 20 feet (6096 mm) shall be provided between every 150 linear feet (45,720 mm) of booth space. A minimum of 30 feet (9144 mm) shall be provided between booths used for cooking and the vehicles, generators, or any other internal combustion engines. A minimum of 30 feet (9144 mm) shall be provided between booths used for cooking and amusement rides or devices. (b) Cooking appliances or devices. (1) Public isolation. Cooking appliances or devices shall be isolated from the public by not less than 4 feet (1219 mm) or by a non-combustible 3-sided barrier between the equipment and devices and the public. (2) Protection. Single-well cooking equipment using combustible oils or solids shall meet the following: a. A noncombustible lid shall be immediately available. The lid shall be of sufficient size to cover the cooking well completely. b. The cooking surface shall not exceed 288 square inches (18,580 cm 2 ). c. The equipment shall be placed on a noncombustible surface; and d. The equipment shall be separated from each other by a horizontal distance of not less than 2 feet (609 mm). (3) Liquefied petroleum gas (LP-gas). LP-gas shall be in accordance with chapter 61 of the International Fire Code and NFPA 58. a. Maximum number and quantity. A maximum of a total aggregate water capacity of 50 gallons (189 L) of LP-gas is permitted at one concession stand or booth used for cooking. b. LP-gas high-pressure cylinder hoses. Hoses shall be designed for a working pressure of 350 PSIG (2413 kPa) with a safety factor of 5 to 1 and shall be continuously marked with LP-GAS, PROPANE, 350 PSI (2413 kPa) WORKING PRESSURE, and the manufacturer's name or trademark. Hose assemblies, after the application of couplings, shall have a design capability of 700 PSIG (4826 kPa). Hose shall not exceed 12 feet (3658 mm) unless approved by the fire code official. c. LP-gas low-pressure cylinder hoses. Hoses with a working pressure of 5 psig shall be allowed when a fix regulator is set a 5 psi and is connected directly to the LP GAS cylinder. The hose shall not exceed 12 feet (3658 mm) unless approved by the fire code official. (4) Storage of containers. Containers shall be stored in accordance with chapter 61 of the International Fire Code. (c) Generators / electrical. The generators shall be installed at least 10 feet (3048 mm) from combustible materials; shall be isolated from the public by physical guard, fence, or enclosure installed at least 3 feet (914 mm) away from the internal combustion power source; and be provided with a compliant portable fire extinguisher per section 906 of the International Fire Code and NFPA 10. (d) Temporary water stations. When outdoor temperatures are expected to exceed 90°F (32.2°C), the event sponsor shall provide and maintain a minimum of one water station for each 5,000-projected attendance. The water station shall include adequate water supply, cups, and a means for rapid replenishing of exhausted water. Each water station shall be located as far apart as practicable to allow ease of access for event attendees.
(O.15,546, 15,860, 16,318, 16,521)
Ask a question about Des Moines law
Corpus searches the Des Moines sections it holds and shows the ones that match, with their citations. Free, no sign-in.
