B — ONE- AND TWO-FAMILY DWELLING BUILDING CODE
City Code of Boise City, Idaho (2026 S-32: current through Ord. 38-26, passed 9-29-2026), Boise City, ID · 56 sections. Independent public-information project, not the official City of Boise City website.
- § 9-1B-1 — PURPOSE
- § 9-1B-2 — CODE ADOPTED
- § 9-1B-3 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R101.1, TITLE
- § 9-1B-4 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R101.2, SCOPE, REPEAL THE EXCEPTION AND REPLACE
- § 9-1B-5 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R102.7, EXISTING STRUCTURES
- § 9-1B-6 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R103, DIVISION OF BUILDING SAFETY
- § 9-1B-7 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R104.10.1, FLOOD HAZARD AREAS
- § 9-1B-8 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R105.2, WORK EXEMPT FROM PERMIT
- § 9-1B-9 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R105.2.1, EMERGENCY REPAIRS
- § 9-1B-10 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R105.2.2, REPAIRS
- § 9-1B-11 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R105.3.1.1, DETERMINATION OF SUBSTANTIALLY IMPROVED OR SUBSTANTIALLY DAMAGED EXISTING BUILDINGS IN FLOOD HAZARD AREAS
- § 9-1B-12 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R105.3.2, TIME LIMITATION OF APPLICATION
- § 9-1B-13 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R105.5, EXPIRATION
- § 9-1B-14 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, ADD SECTION R105.10, PERMIT TRANSFER
- § 9-1B-15 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R106.1, SUBMITTAL DOCUMENTS
- § 9-1B-16 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R107.1, TEMPORARY STRUCTURES - GENERAL
- § 9-1B-17 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R107.3, TEMPORARY POWER
- § 9-1B-18 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R108.2, SCHEDULE OF PERMIT FEES
- § 9-1B-19 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R108.3, BUILDING PERMIT VALUATIONS
- § 9-1B-20 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R108.5, FEE REFUNDS
- § 9-1B-21 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R108.6, WORK COMMENCING BEFORE PERMIT ISSUANCE
- § 9-1B-22 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R109.1.3, FLOODPLAIN INSPECTIONS
- § 9-1B-23 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R109.4, APPROVAL REQUIRED
- § 9-1B-24 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, ADD SECTION R110.1.1, CERTIFICATE OF COMPLETION
- § 9-1B-25 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R110.4, TEMPORARY OCCUPANCY
- § 9-1B-26 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R111.1, CONNECTION OF SERVICE UTILITIES
- § 9-1B-27 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, ADD SECTION R111.4, AUTHORITY TO DISCONNECT UTILITIES FOR OCCUPANCY VIOLATIONS
- § 9-1B-28 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R112.1, BUILDING CODE BOARD OF APPEALS, ADD SECTION R112.1.1, APPEALS TO THE BUILDING CODE BOARD OF APPEALS AND ADD SECTION R112.1.2, APPEAL PROCEDURE
- § 9-1B-29
- § 9-1B-30 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R114, STOP WORK ORDER
- § 9-1B-31 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, ADD SECTION R115, UNSAFE STRUCTURES AND EQUIPMENT AND SECTION R115.1, CONDITIONS
- § 9-1B-32 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R202, DEFINITION FOR TOWNHOUSE
- § 9-1B-33 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, TABLE R301.2(1), CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
- § 9-1B-34 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R301.2.1.2, PROTECTION OF OPENINGS, IS DELETED
- § 9-1B-35 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, TABLE R302.1(1), EXTERIOR WALLS
- § 9-1B-36 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, TABLE R302.6, DWELLING-GARAGE SEPARATION
- § 9-1B-37 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R303.4, MECHANICAL VENTILATION
- § 9-1B-38 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R309.3, FLOOD HAZARD AREAS
- § 9-1B-39 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R313.1, TOWNHOUSE AUTOMATIC FIRE SPRINKLER SYSTEMS EXCEPTION
- § 9-1B-40 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R313.2, ONE- AND TWO-FAMILY DWELLINGS AUTOMATIC FIRE SPRINKLER SYSTEMS, IS DELETED
- § 9-1B-41 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R314.2.2, ALTERATIONS, REPAIRS AND ADDITIONS, DELETE EXCEPTION #2
- § 9-1B-42 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, ADD SECTION R314.7.5, HEAT DETECTOR WITHIN GARAGES
- § 9-1B-43 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R315.2.2, ALTERATIONS, REPAIRS AND ADDITIONS, DELETE EXCEPTION #2
- § 9-1B-44 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R322.1, FLOOD-RESISTANT CONSTRUCTION, GENERAL
- § 9-1B-45 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R322.1.10, AS-BUILT ELEVATION DOCUMENTATION
- § 9-1B-46 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R322.2.1, ELEVATION REQUIREMENTS
- § 9-1B-47 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R322.2.2, ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION, SUBPARAGRAPH 2.1
- § 9-1B-48 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, TABLE R403.1(1) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION, TABLE R403.1(2) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION WITH BRICK VENEER, TABLE R403.1(3) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS WITH CAST-IN-PLACE OR FULLY GROUTED MASONRY WALL CONSTRUCTION, AND TABLE R403.4 MINIMUM DEPTH (D) AND WIDTH (W) OF CRUSHED STONE FOOTINGS, ARE DELETED
- § 9-1B-49 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, ADD TABLE R403.1, MINIMUM WIDTH OF CONCRETE, PRECAST, OR MASONRY FOOTINGS
- § 9-1B-50 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R403.1.1, MINIMUM SIZE
- § 9-1B-51 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R602.10, WALL BRACING
- § 9-1B-52 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R903.1, GENERAL ROOF COVERING
- § 9-1B-53 — ADDITION OF GRADING PROVISIONS RELATED TO ONE-AND-TWO-FAMILY DWELLINGS
- § 9-1B-54 — ADDITION OF MINIMUM STANDARDS FOR MODULAR NON-HUD STRUCTURES AND MANUFACTURED PRE-HUD STRUCTURES
- § 9-1B-55 — FIRE SPRINKLER AND ALTERNATIVE EXTINGUISHING SYSTEM PERMITS, PLAN REVIEW, INSPECTIONS, AND FEES
- § 9-1B-56 — FIRE ALARM SYSTEM PERMITS, PLAN REVIEW, INSPECTIONS, AND FEES