§ 9-1B-49 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, ADD TABLE R403.1, MINIMUM WIDTH OF CONCRETE, PRECAST, OR MASONRY FOOTINGS
City Code of Boise City, Idaho (2026 S-32: current through Ord. 38-26, passed 9-29-2026) · Boise City Code § 9-1B-49
Corpus is an independent public-information project, not the official City of Boise City website. Stable reference: corpuslaw.us/code/a7cbee5b-6984-4749-aa41-88a8e9d12afa
9-1B-49: IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, ADD TABLE R403.1, MINIMUM WIDTH OF CONCRETE, PRECAST, OR MASONRY FOOTINGS:
Add Table R403.1, Minimum Width Of Concrete, Precast, Or Masonry Footings as follows: TABLE R403.1 MINIMUM WIDTH OF CONCRETE, PRECAST, OR MASONRY FOOTINGS (inches)a | LOAD-BEARING VALUE OF SOIL (psf) 1,500 | 2,000 | 3,000 | 4,000 | LOAD-BEARING VALUE OF SOIL (psf) 1,500 | 2,000 | 3,000 | 4,000 Conventional light-frame construction 1-Story | 12 | 12 | 12 | 12 2-Story | 15 | 12 | 12 | 12 3-Story | 23 | 17 | 12 | 12 4-inch brick veneer over light-frame or 8-inch hollow concrete masonry 1-Story | 12 | 12 | 12 | 12 2-Story | 21 | 16 | 12 | 12 3-Story | 32 | 24 | 16 | 12 8-inch solid or fully grouted masonry 1-Story | 16 | 12 | 12 | 12 2-Story | 29 | 21 | 14 | 12 3-Story | 42 | 32 | 21 | 16 For SI: 1 inch = 25.4mm, 1 pound per square foot = 0.0479 kPa. a. Where minimum footing width is twelve (12) inches, use of a single wythe of solid or fully grouted twelve (12) inch nominal concrete masonry units is permitted. (Ord. 40-20, 12-1-2020, eff. 1-1-2021)
Ask a question about Boise City law