§ 9-1B-39 — IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R313.1, TOWNHOUSE AUTOMATIC FIRE SPRINKLER SYSTEMS EXCEPTION
City Code of Boise City, Idaho (2026 S-32: current through Ord. 38-26, passed 9-29-2026) · Boise City Code § 9-1B-39
Corpus is an independent public-information project, not the official City of Boise City website. Stable reference: corpuslaw.us/code/d7152d25-e1ae-4b7c-932d-9e5c628df798
9-1B-39: IRC ONE-AND-TWO-FAMILY DWELLING BUILDING CODE AMENDMENT, SECTION R313.1, TOWNHOUSE AUTOMATIC FIRE SPRINKLER SYSTEMS EXCEPTION:
The exception to section R313.1 shall be modified as follows: Exception. Automatic residential fire sprinkler systems shall not be required in townhouses where either two (2) 1-hour fire-resistance rated walls or a common two-hour fire-resistance rated wall, as specified in item number 2 of section R302.2.2, is installed between dwelling units or when additions or alterations are made to existing townhouses that do not have an automatic residential fire sprinkler system installed. (Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 40-20, 12-1-2020, eff. 1-1-2021)