Sec. 15-2. - Use of explosives.

(a) Scope. The provisions of this section regulating the use of explosives are to be observed in addition to the requirements of the adopted edition of the International Fire Code. Where requirements conflict the provisions of this section apply. (b) Permit required. A blasting permit shall be required prior to the use of any explosive within the city. Permits shall be issued by the bureau of fire prevention after compliance with the requirements of this section and with the approval of the fire chief. (c) Site plan required. When applying for a blasting permit the applicant shall submit a site plan of the proposed blasting operation which identifies any and all utilities and structures within a one-hundred-foot radius of each explosive blast. The site plan shall also identify the proposed location of all seismographic sensing devices. (d) Insurance required. Before a permit for the use of explosives is issued as provided in the current edition of the International Fire Code, the applicant shall file with the city a liability insurance policy on an occurrence from basis in the principal amount of one million dollars ($1,000,000) combined single limit for the purpose of the payment of all damages to persons or property which arise from or are caused by the conduct of any act authorized by the permit. The city of Lewiston shall be named as an additional insured for any liability resulting from the issuance of said permit. Such insurance policy shall be certified by the maker or underwriter to be unencumbered by claims or legal proceedings which may reduce available coverage below the one-million-dollar limit. The fire chief may require a greater or lesser amount when, in his opinion, conditions at the location of use indicate a greater or lesser amount is required. Public agencies and utilities shall be exempt from this insurance requirement. (e) Release of liability. Before any permit shall issue the applicant for said permit shall agree in writing to indemnify and hold harmless the city from any and all liability resulting from the issuance of the blasting permit and any blasting activity associated with the permit. The applicant shall also agree in writing to defend the city in any court against any and all claims arising from the issuance of the permit or any blasting activity associated with the permit. (f) Demonstration of alternate method. Prior to consideration of a blasting permit the applicant must demonstrate to the director of public works that excavation cannot be accomplished by use of suitable power excavation equipment. Suitable power excavation equipment is defined as a single-tooth ripper pulled by a crawler-type tractor having a flywheel rating of not less than three hundred (300) horsepower. When, in the opinion of the director of public works, the circumstances of the proposed blasting of such demonstration is impractical, this subsection may be waived. (g) Permit fees. A blasting permit fee shall be paid for each blasting permit application and detonation. Said fees shall be paid when the application is made. The application fee shall be nonrefundable. Blasting permit fees shall be set by resolution of the Lewiston city council. (h) Notification required. Whenever blasting is being conducted in the vicinity of gas, electric, water, sewer, fire alarm, telephone, telegraph or steam utilities or any structure, the blaster shall notify the appropriate representative of such utility and owner of the closest structure and such additional persons identified by the fire chief at least twenty-four (24) hours and no more than ten (10) days in advance of blasting. Said notification shall specify the location and intended time of such blasting. Documentation of notification must be filed with and approved by the fire chief prior to each blasting event. In an emergency, or in the event all the requirements of this chapter have been met, this time limit may be waived or reduced in the discretion of the fire chief. At the time of notification the blaster shall offer to perform and agree to a date and time to conduct a pre-blast survey of the closest structures and property identified by the fire chief to establish all pre-blast damage, including cracks in walls, floors, ceilings and around windows, loose bricks and other defects inside and outside the structures. The blaster must make a minimum of six (6) attempts to contact property owners. Four (4) attempts shall be between the hours of 8:00 a.m. and 6:00 p.m. and two (2) attempts between the hours of 6:00 p.m. and 9:00 p.m. If attempts are unsuccessful, a notarized statement detailing the address, dates and time of the attempts or the name of the person making the attempts to contact shall be submitted to the fire chief for approval to proceed with blasting activity. (i) Seismographic equipment required. Seismographic equipment, approved by the fire chief and of a type that measures and records seismographic information resulting from blasting activities must be placed in approved locations during all blasting events. Copies of all seismic activity recorded during each blasting event shall be submitted to the fire chief immediately following each day of blasting. Professional assistance may be required by the fire chief to interpret and certify recorded data at the expense of the blasting contractor. Requirements of this section may be waived by the fire chief for approved single charged detonations. The following formula shall be used in the determination of charge size relative to distance from exposure for single charged detonations: [image omitted; see the official code] (j) Blasting operations. The permit holder shall provide sufficient personnel to maintain visual contact with all areas surrounding the blasting site to control vehicular and pedestrian access to the entire blasting area. A method, approved by the fire chief, of signaling or communication between these personnel and the blaster must be provided. Blasting that produces peak particle velocities in excess of 0.5 inches per second at the foundation of any structure is prohibited regardless of the frequency of ground vibration. (k) Revocation of permit. Failure to provide required information or conform to the requirements of this section may cause the permit for the proposed blasting to be canceled and revoked at the discretion of the fire chief. Any person who willfully continues with a blasting event after a permit has been denied, canceled or revoked shall be guilty of a misdemeanor and punished as provided in section 1-7 of this Code.

(Ord. No. 4088, § 4, 11-22-93; Ord. No. 4555, § 4, 1-10-11; Ord. No. 4770, § 2, 4-13-20)

Ask a question about Lewiston law

Corpus searches the Lewiston sections it holds and shows the ones that match, with their citations. Free, no sign-in.