§ 10-1-2 — Amendments to International Building Code
Code of Ordinances of the City of Meridian, Idaho (Supp. No. 14: codified through Ordinance No. 26-2129, enacted July 7, 2026) · Meridian Code of Ordinances § 10-1-2
Corpus is an independent public-information project, not the official City of Meridian website. Stable reference: corpuslaw.us/code/939a7892-d85a-4663-8f97-9537610c0aba
10-1-2. - Amendments to International Building Code.
The following amendments to the IBC shall apply: A. IBC section 105.2, exception 1 under "Building," shall be amended to read as follows: Building: 1. One-story detached accessory structures used as tool and storage sheds, playhouses, emissions testing facilities, and similar uses, provided that the floor area is not greater than 120 square feet (11m 2 ). B. IBC section 107.2.6 shall be amended to read as follows: Site Plan. The construction documents submitted with the application for permit shall be accompanied by a site plan showing, to scale, the size and location of new construction and existing structures on the site, distances from lot lines, the established street grades, and the proposed finished grades. The site plan shall be drawn in accordance with an accurate boundary line survey. In the case of demolition, the site plan shall show construction to be demolished and the location and size of existing structures and construction that are to remain on the site or plot. The building official is authorized to waive or modify the requirement for a site plan when the application for permit is for alteration or repair or when otherwise warranted. All development located in the Meridian floodplain overlay district is required to meet the provisions of the Meridian flood damage prevention ordinance, title 10, chapter 6, Meridian city code. C. IBC section 109.2 shall be amended to provide as follows: Schedule of Permit Fees. The fee for each permit shall be as set forth pursuant to a schedule of permit fees as established by resolution of the city council. The determination of value or valuation under any of the provisions of this code shall be made by the building official. The value to be used in computing the building permit and building plan review fees shall be the total value of all construction work for which the permit is issued as well as all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevators, fire extinguishing systems and any other permanent equipment. Final building permit valuation shall be set by the building official for all permits that require initial estimated valuation and final estimated valuation by the applicant. Payment of permit fees is required at the time the permit is issued. Permits shall not be issued or considered valid until fees are paid. D. A new section, section 109.6.1, shall be added to the IBC to provide as follows: Permit Fee Refunds. Up to eighty percent (80%) of the fees paid for a valid permit may be refunded to the permit holder upon request, if the permit holder has not commenced any work under said permit. The permit holder shall request such refund in writing to the building official no later than one hundred eighty (180) days following the date of permit issuance. Plan review fees shall not be refunded in part or in whole after completion of plan review. E. A new section, section 109.7, shall be added to the IBC to provide as follows: Permit Transfer. A building permit granted pursuant to this code may be transferred from one permit holder to another permit holder upon written request by the current permit holder to the building official. Expired permits may not be transferred. No permit transfer may be made without written approval of the building official; if transfer is attempted without written approval of the building official, such permit shall be deemed void. F. IBC section 202, Definition for Townhouse, shall be amended to provide as follows: A single-family dwelling unit constructed in a group of three or more attached units in which each unit extends from the foundation to the roof, separated by property lines, and with open space on at least two sides. G. IBC section 312.1 shall be amended with the deletion of the requirement for agricultural buildings to comply with the IBC. H. IBC section 1612 shall be deleted, and replaced with language to provide as follows: Flood Loads. All development located in the Meridian floodplain overlay district is required to meet the provisions of the Meridian flood damage prevention ordinance, title 10, chapter 6, Meridian city code. I. A new section, section 1805.3.4, shall be added to the IBC to provide as follows: Waterproofing Hydraulic Elevator Shaft Pits. Elevator shafts shall be designed to prevent the intrusion of water into the hydraulic elevator shaft pit, with accommodation made for the high groundwater table in the city of Meridian, in accordance with American Society of Mechanical Engineers standard A17.1, section 2.2.2.3. J. IBC section 1807.1.4 shall be deleted, and replaced with language to provide as follows: Wood Footings Or Foundations. Regardless of the provisions of the IRC or IBC, this chapter, related chapters, appendices or tables, the city of Meridian shall not allow the use of wood, treated or otherwise, for footings or foundations. K. IBC section 3002.4 shall be amended to provide as follows: Elevator Car To Accommodate Ambulance Stretcher. Where elevators are provided in buildings above or below grade plane, at least one (1) elevator shall be provided for fire department emergency access to all floors. The elevator car shall be of such a size and arrangement to accommodate an ambulance stretcher twenty-four by eighty-four inches (24" x 84") with not less than five inches (5") radius corners, in the horizontal, open position and shall be identified by the international symbol for emergency medical services (star of life). The symbol shall not be less than three inches (3") high, and shall be placed inside on both sides of the hoistway door frame. L. IBC Section 3113.1 shall be deleted, and replaced with language to provide as follows: Relocatable Buildings. The provisions of this Section shall apply to relocatable buildings. Relocatable buildings manufactured after the effective date of this code shall comply with the applicable provisions of this code; title 39, chapter 43, Idaho Code; and IDAPA 07.03.03. Exception: This Section shall not apply to manufactured housing used as dwellings. M. IBC section 305.2.3 shall be deleted, and replaced with language to provide as follows: Twelve (12) Or Fewer Children In A Dwelling Unit. A facility such as the above within a dwelling unit and having twelve (12) or fewer children receiving such daycare shall be classified as a group R-3 occupancy or shall comply with the International Residential Code. N. IBC Section 308.2.4 shall be deleted, and replaced with language to provide as follows: Five (5) or fewer persons receiving custodial care. A facility with five (5) or fewer persons receiving custodial care shall be classified as a Group R-3 occupancy or shall comply with the International Residential Code. O. IBC Section 308.3.2 shall be deleted, and replaced with language to provide as follows: Five (5) or fewer persons receiving medical care. A facility with five (5) or fewer persons receiving medical care shall be classified as a Group R-3 occupancy. P. IBC section 308.5.4 shall be deleted, and replaced with language to provide as follows: Persons Receiving Care In A Dwelling Unit. A facility such as the above within a dwelling unit and having twelve (12) or fewer children receiving daycare or having five (5) or fewer persons receiving custodial care shall be classified as a group R-3 occupancy or shall comply with the International Residential Code. Q. IBC section 310.4 shall be deleted, and replaced with language to provide as follows: Residential Group R-3. Residential Group R-3 occupancies where the occupants are primarily permanent in natures and not classified as group R-1, R-2, R-4, E, or I, including: 1. Buildings that do not contain more than two (2) dwelling units. 2. Care facilities that provide accommodations for five (5) or fewer persons receiving personal care, custodial care or medical care. 3. Congregate living facilities (nontransient) with sixteen (16) or fewer occupants, including boarding houses (nontransient), convents, dormitories, fraternities and sororities, and monasteries. 4. Congregate living facilities (transient) with ten (10) or fewer occupants, including boarding houses (transient). 5. Dwelling units providing day care for twelve (12) or fewer children. 6. Lodging houses (transient) with five (5) or fewer guest rooms and ten (10) or fewer occupants. R. IBC section 310.4.1 shall be deleted, and replaced with language to provide as follows: Care Facilities Within A Dwelling. Care facilities for twelve (12) or fewer children receiving daycare or for five (5) or fewer persons receiving personal care or custodial care that are within a one- or two-family dwelling are permitted to comply with the International Residential Code. S. IBC section 2902.6 shall be deleted, and replaced with language to provide as follows: Drinking fountains shall not be required for an occupant load of thirty (30) or fewer. T. Footnote (e) to table 2902.1, Minimum Number Of Required Plumbing Fixtures, shall be deleted, and replaced with language to provide as follows: For business occupancies, excluding restaurants, and mercantile occupancies with an occupant load of thirty (30) or fewer, service sinks shall not be required. U. IBC Appendices B, H, and I shall be mandatory.
(Ord. 17-1754, 11-28-2017, eff. 1-1-2018; Ord. No. 20-1905, § 2, 12-1-2020, eff. 1-1-2021)
Ask a question about Meridian law
Corpus searches the Meridian sections it holds and shows the ones that match, with their citations. Free, no sign-in.
