§ 10-1-3 — Amendments to International Residential Code

Code of Ordinances of the City of Meridian, Idaho (Supp. No. 14: codified through Ordinance No. 26-2129, enacted July 7, 2026) · Meridian Code of Ordinances § 10-1-3

Corpus is an independent public-information project, not the official City of Meridian website. Stable reference: corpuslaw.us/code/daddd2ee-5490-4261-858f-ad59ca0f5c93

10-1-3. - Amendments to International Residential Code.

The following amendments to the IRC shall apply: A. Parts VII (plumbing), VIII (electrical), and IV (Energy Conservation) shall be deleted. B. The exception under Section R101.2 Scope shall be deleted and replaced with the following: Exception: The following shall also be permitted to be constructed, in accordance with this code: 1. Owner-occupied lodging houses with five (5) or fewer guestrooms and ten (10) or fewer total occupants. 2. A care facility with five (5) or fewer persons receiving custodial care within a dwelling unit or single-family dwelling. 3. A care facility for five (5) or fewer persons receiving personal care that are within a dwelling unit or single-family dwelling. 4. A care facility with twelve (12) or fewer children receiving day care within a dwelling unit or single-family dwelling. C. Section R104.10.1 Flood hazard areas shall be deleted. D. Item 2 of the "Building" subsection of IRC section R105.2, Work Exempt from Permit, shall be deleted and replaced with the following: Fences not over six feet (6') high may be exempted from the requirement for a building permit in the absence of any other applicable land use regulations governing the installation, height, type, or other aspect thereof. E. Item 7 of the "Building" subsection of IRC section R105.2, Work Exempt From Permit, shall be deleted and replaced with the following: Prefabricated swimming pools that are not greater than four (4) feet (one thousand, two hundred nineteen (1219) mm) deep. F. A new item, no. 11, shall be added to the "Building" subsection of IRC section R105.2, Work Exempt From Permit: Flagpoles. G. A new section, section R108.5.1, shall be added to the IRC to provide as follows: Permit Fee Refunds. Up to eighty percent (80%) of the fees paid for a valid permit may be refunded to the permit holder upon request, if the permit holder has not commenced any work under said permit. The permit holder shall request such refund in writing to the community development director or designee no later than one hundred eighty (180) days following the date of permit issuance. Plan review fees shall not be refunded in part or in whole after completion of plan review. H. A new section, section R108.5.2, shall be added to the IRC to provide as follows: Permit Transfer. A building permit granted pursuant to this code may be transferred from one permit holder to another permit holder upon written request by the current permit holder to the Building Official. Expired permits may not be transferred. No permit transfer may be made without written approval of the Building Official; if transfer is attempted without written approval, such permit shall be deemed void. I. Section R109.1.3 shall be deleted and replaced with the following: R109.1.3 Floodplain inspections. For construction in areas prone to flooding as established by Table R301.2(1), upon placement of the lowest floor, including basement, the building official is authorized to require submission of documentation of the elevation of the lowest floor, including basement, required in Section R322. J. Section R202, Definition for Townhouse, shall be amended to provide as follows: A single-family dwelling unit constructed in a group of three or more attached units in which each unit extends from the foundation to the roof, separated by property lines, and with open space on at least two sides. K. Table R301.2(1), Climate and Geographic Design Criteria, shall be completed with criteria as follows: GROUND SNOW LOAD: 20 psf. Design roof load shall not be less than a uniform snow load of 25 psf. WIND DESIGN SPEED (mph): 115 mph for risk occupancy II or less; 120 mph for risk occupancy III or greater. WIND DESIGN TOPOGRAPHIC EFFECTS: No, in accordance with Section R301.2.1.5 SEISMIC DESIGN CATEGORY: C WEATHERING: Severe FROST LINE DEPTH: 24 inches TERMITE: Slight to Moderate WINTER DESIGN TEMP: 10 degrees F (annual mean temperature: 51.1 degrees F). The outdoor design dry-bulb temperature shall be selected from the columns of 97 ½ percent values for winter from Appendix D of the Idaho State Plumbing Code or as determined by the Building Official. ICE BARRIER UNDER LAYMENT REQUIRED: No FLOOD HAZARDS: Refer to Title 10, Chapter 6, Meridian City Code, Flood Damage Prevention. L. Section R301.2.1.2, Protection of Openings, shall be deleted. M. IRC section R301.2.4, shall be deleted, and replaced with language to provide as follows: Floodplain Construction. All development located in the Meridian floodplain overlay district is required to meet the provisions of the Meridian flood damage prevention ordinance, title 10, chapter 6, Meridian City Code. N. IRC Table R302.1(1), Exterior Walls shall be deleted, and replaced with language to provide as follows: Exterior Wall Element | Minimum Fire-Resistance Rating | Minimum Fire Separation Distance Walls | Fire-resistance rated | 1 hour—Tested in accordance with ASTM E119, UL 263, or Section 703.3 of the International Building Code with exposure from both sides | <3 feet Not fire-resistance rated | 0 hours | ≥3 feet Projections | Fire-resistance rated | 1 hour on the underside, or heavy timer, or fire retardant-treated wood a,b | ≥2 feet to <3 feet Not fire-resistance rated | 0 hours | ≥3 feet Openings in Walls | Not allowed | N/A | <3 feet 25% maximum of wall area | 0 hours | ≥3 feet to <5 feet Unlimited | 0 hours | ≥5 feet Penetrations | All | Comply with Section R302.4 | <3 feet None required | ≥3 feet For SI: 1 foot = 304.8 mm. N/A = Not Applicable a The fire-resistance rating shall be permitted to be reduced to zero (0) hours on the underside of the eave overhang if fireblocking is provided from the wall top plate to the underside of the roof sheathing. b The fire-resistance rating shall be permitted to be reduced to zero (0) hours on the underside of the rake overhang where gable vent openings are not installed. O. Section R302.13, Fire protection of floors, shall be deleted. P. Section R303.4 shall be deleted, and replaced with the following: R303.4 Mechanical Ventilation. Dwelling units shall be provided with whole-house mechanical ventilation in accordance with Section M1505.4. Q. IRC section R302.6, Dwelling/Garage Fire Separation, shall be amended to provide as follows: Dwelling/Garage Fire Separation. Walls and ceiling of garages shall be covered with not less than 5 / 8 -inch (15.9 mm) type X gypsum board or equivalent. R. The exception to IRC section R313.1, Townhouse Automatic Fire Sprinkler Systems, shall be deleted, and replaced with language to provide as follows: Exception: Automatic residential fire sprinkler systems shall not be required in townhouses where either two (2) one-hour fire-resistance rated walls or a common two-hour fire-resistance rated wall, as specified in item number 2 of Section R302.2.2 is installed between dwelling units or when additions or alterations are made to existing townhouses that do not have an automatic residential fire sprinkler system installed. S. IRC section R313.2 shall be deleted. T. The exceptions to Section R314.2.2 Alterations, repairs and additions, shall be deleted, and replaced with the following: Exceptions: 1. Work involving the exterior surfaces of dwellings, such as, but not limited to, replacement of roofing or siding, or the addition or replacement of windows or doors, or the addition of a porch or deck or electrical permits, are exempt from the requirements of this section. 2. Installation, alteration or repairs of plumbing or mechanical systems are exempt from the requirements of this section. U. The exceptions to Section R315.2.2 Alterations, repairs and additions, shall be deleted, and replaced with the following: Exceptions: 1. Work involving the exterior surfaces of dwellings, such as, but not limited to, replacement of roofing or siding, or the addition or replacement of windows or doors, or the addition of a porch or deck or electrical permits, are exempt from the requirements of this section. 2. Installation, alteration or repairs of noncombustion plumbing or mechanical systems are exempt from the requirements of this section. V. IRC section R322 shall be deleted, and replaced with language to provide as follows: Flood-Resistant Construction. All development located in the Meridian floodplain overlay district is required to meet the provisions of the Meridian flood damage prevention ordinance, title 10, chapter 6, Meridian city code. W. IRC section R402.1 shall be amended to provide as follows: Wood. Regardless of the provisions of the IBC or IRC, this chapter, related chapters, appendices or tables, the city of Meridian shall not allow the use of wood, treated or otherwise, for footings or foundations. X. The following tables shall be deleted: Table R403.4 Minimum Depth (D) and Width (W) of Crushed Stone Footings (inches), Table R403.1(1) Minimum Width and Thickness for Concrete Footings for Light-Frame Construction (inches), Table R403.1(2) Minimum Width and Thickness for Concrete Footings for Light-Frame Construction and Brick Veneer (inches), and Table R403.1(3) Minimum Width and Thickness for Concrete Footings with Cast-In-Place or Fully Grouted Masonry Wall Construction (inches). Y. A new table, Table R403.1, shall be added, to read as follows: TABLE R403.1 MINIMUM WIDTH OF CONCRETE, PRECAST, OR MASONRY FOOTINGS (inches)a LOAD-BEARING VALUE OF SOIL (psf) 1,500 | 2,000 | 3,000 | ≥ 4,000 Conventional light-frame construction 1-Story | 12 | 12 | 12 | 12 2-Story | 15 | 12 | 12 | 12 3-Story | 23 | 17 | 12 | 12 4-inch brick veneer over light frame or 8-inch hollow concrete masonry 1-Story | 12 | 12 | 12 | 12 2-Story | 21 | 16 | 12 | 12 3-Story | 32 | 24 | 16 | 12 8-inch solid or fully grouted masonry 1-Story | 16 | 12 | 12 | 12 2-Story | 29 | 21 | 14 | 12 3-Story | 42 | 32 | 21 | 16 For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa. a Where minimum footing width is twelve (12) inches, use of a single width of solid or fully grouted twelve (12)-inch nominal concrete masonry units is permitted. Z. Section R403.1.1 shall be deleted and replaced with the following: R403.1.1 Minimum size. Minimum sizes for concrete and masonry footings shall be as set forth in Table R403.1 and Figure R403.1(1). The footing width (W) shall be based on the load bearing value of the soil in accordance with Table R401.4.1. Spread footings shall be at least six (6) inches in thickness (T). Footing projections (P) shall be at least two (2) inches and shall not exceed the thickness of the footing. The size of footings supporting piers and columns shall be based on the tributary load and allowable soil pressure in accordance with Table R401.4.1. AA. IRC section R602.10 shall be deleted, and replaced with the following: Wall Bracing. Buildings shall be braced in accordance with this section or, when applicable section R602.12, or the most current edition of APA System Report SR-102 as an alternate method. Where a building, or portion thereof, does not comply with one (1) or more of the bracing requirements in this section, those portions shall be designated and constructed in accordance with section R301.1. BB. IRC Appendices A, B, C, D, H, I, and Q shall be mandatory.

(Ord. 17-1754, 11-28-2017, eff. 1-1-2018; Ord. No. 20-1905, § 3, 12-1-2020, eff. 1-1-2021)

Ask a question about Meridian law

Corpus searches the Meridian sections it holds and shows the ones that match, with their citations. Free, no sign-in.