10-5-2. - Amendments to International Mechanical Code.
The following amendments to the IMC shall apply: A. The following definitions provided in IMC section 202, Definitions, shall be amended as follows: Light-Duty Cooking Appliance: Light-duty cooking appliances include gas and electric ovens (including standard, bake, roasting, revolving, retherm, convection, combination convection/steamer, countertop conveyorized baking/finishing, deck, pastry ovens), electric and gas steam jacketed kettles, electric and gas pasta cookers, electric and gas compartment steamers (both pressure and atmospheric) and electric and gas cheesemelters. Medium-Duty Cooking Appliance: Medium-duty cooking appliances include electric discrete element ranges (with or without oven), electric and gas hot-top ranges, electric and gas griddles, electric and gas double sided griddles, electric and gas fryers (including open deep fat fryers, donut fryers, kettle fryers and pressure fryers), electric and gas conveyor pizza ovens, electric and gas tilting skillets (braising pans) and electric and gas rotisseries. B. The following language shall be added to IMC section 401.1 Scope: Exception: The principles specified in ASHRAE 62-2010 may be used as an alternative to this chapter to demonstrate compliance with required ventilation air for occupants. C. The following language shall be added to IMC section 504.8.1 Material And Size: Exception: Dryer duct may be constructed of 0.013 (30 gage) or equivalent if prefabricated 0.016 (28 gage) ducts and fittings are not available. D. The following language shall be added to IMC table 603.4 Duct Construction Minimum Sheet Metal Thickness For Single Dwelling Units: Exception: Round duct, enclosed rectangular ducts and fittings less than fourteen (14) inches may be constructed of 0.013 (30 gage) or equivalent if prefabricated 0.016 (28 gage) ducts and fittings are not available.
(Ord. 17-1754, 11-28-2017, eff. 1-1-2018; Ord. No. 20-1905, § 9, 12-1-2020, eff. 1-1-2021)
Ask a question about Meridian law
Corpus searches the Meridian sections it holds and shows the ones that match, with their citations. Free, no sign-in.