§ 10-5-4 — Amendments to Part V (mechanical) and Part VI (fuel gas) of the International Residential Code

Code of Ordinances of the City of Meridian, Idaho (Supp. No. 14: codified through Ordinance No. 26-2129, enacted July 7, 2026) · Meridian Code of Ordinances § 10-5-4

Corpus is an independent public-information project, not the official City of Meridian website. Stable reference: corpuslaw.us/code/72ed87bb-13f0-4bd0-946c-514607835a96

10-5-4. - Amendments to Part V (mechanical) and Part VI (fuel gas) of the International Residential Code.

A. Two new sections, sections M1201.3 and G2402.4 (IFGC 201.4) shall be added, to read as follows: Alternative Materials, Design And Methods Of Construction Equipment. The provisions of this part of the code are not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved. An alternative material, design or method of construction shall be approved where the authority having jurisdiction finds that the proposed design is satisfactory and complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in this code. Compliance with the specific performance-based provisions of this part of the code in lieu of specific requirements of this code shall also be permitted as an alternate. B. Two new sections, sections M1201.3.1 and G2402.4.1 (IFGC 201.4.1) shall be added, to read as follows: Tests. Whenever there is insufficient evidence of compliance with the provisions of this part of the code, or evidence that a material or method does not conform to the requirements of this part of the code, or in order to substantiate claims for alternative materials or methods, the authority having jurisdiction shall have the authority to require tests as evidence of compliance to be made at no expense to the jurisdiction. Test methods shall be as specified in this code or by other recognized test standards. In the absence of recognized and accepted test methods, the authority having jurisdiction shall approve the testing procedures. Tests shall be performed by an approved agency. Reports of such tests shall be retained by the authority having jurisdiction for the period required for retention of public records. C. A new section, section M1203.1, shall be added, to read as follows: Carbon Monoxide Alarms. For new construction, an approved carbon monoxide alarm shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms in dwelling units within which fuel-fired appliances are installed and in dwelling units that have attached garages. D. A new section, section M1203.2, shall be added, to read as follows: Where Required In Existing Dwellings. Where interior work requiring a permit occurs in existing dwellings that have attached garages or in existing dwellings within which fuel-fired appliances exist, carbon monoxide alarms shall be provided in accordance with this section. E. A new section, section M1203.3, shall be added, to read as follows: Alarm Requirements. Single station carbon monoxide alarms shall be listed as complying with UL 2034 and shall be installed in accordance with this code and the manufacturer's installation instructions. F. A new sentence shall be added to section M1502.4.1, to read as follows: Material And Size. Dryer duct may be constructed of 0.013 (30 gage) or equivalent if prefabricated 0.016 (28 gage) ducts and fittings are not available. G. Section M1502.4.2 shall be deleted, and replaced with language to read as follows: Duct Installation. Exhaust ducts shall be supported at four (4) foot (1219 mm) intervals and secured in place. The insert end of the duct shall extend into the adjoining duct or fitting in the direction of airflow. Ducts shall not be joined with screws or similar fasteners that protrude into the inside of the duct. H. The following language shall be added to table M1601.1.1(2): Round duct, enclosed rectangular ducts and fittings less than fourteen (14) inches may be constructed of 0.013 (30 gage) or equivalent if prefabricated 0.016 (28 gage) ducts and fittings are not available. I. The last sentence of section G2417.4 (406.4) shall be deleted, and replaced with language to read as follows: Mechanical gauges used to measure test pressure shall have a range such that the highest end of the scale is not greater than two (2) times the test pressure nor lower than one and one-half (1.5) times the test pressure. J. Section G2417.4.1 (IFGC 406.4.1) shall be deleted, and replaced with language to read as follows: The test pressure shall not be less than twenty (20) psig (one hundred forty (140) kPa gauge) test pressure shall be required for systems with a maximum working pressure up to ten (10) inches water column. For systems with a maximum working pressure between ten (10) inches water column and ten (10) psig (seventy (70) kPa gauge), not less than sixty (60) psig (four hundred twenty (420) kPa gauge) test pressure shall be required. For systems over ten (10) psig (seventy (70) kPa gauge) working pressure, minimum test pressure shall be no less than six (6) times working pressure. K. Section G2417.4.2 (IFGC 406.4.2) shall be deleted, and replaced with language to read as follows: The test duration shall not be less than twenty (20) minutes. L. A new section, section G2427.4.1.2, shall be added, to read as follows: Testing. All plastic pipe within a dwelling used for venting flue gases shall be tested at five (5) psi for fifteen (15) minutes.

(Ord. 14-1633, 12-2-2014, eff. 1-1-2015; Ord. No. 20-1905, § 11, 12-1-2020, eff. 1-1-2021)