For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10-34-10 — Design standards/requirements

Code of Ordinances of the City of Nampa, Idaho (Codified through Ordinance No. 4907, adopted January 5, 2026 (Supp. No. 16, Update 1)) · Nampa Code of Ordinances § 10-34-10

Corpus is an independent public-information project, not the official City of Nampa website. Stable reference: corpuslaw.us/code/9d6eb326-4558-48e3-9f93-a622ed83b6ca

10-34-10. - Design standards/requirements.

A. The following standards apply to qualifying projects in all zones except the downtown zones, which standards are in chapter 15 of title 10 and the IL and IH zones, which standards are in subsection 10-34-10.B of this chapter. 1. Structure exteriors and finish materials/elements. Wall facades of new buildings or new additions shall be reviewed as specified hereafter (Exception: multi-family expansion projects shall maintain consistency of materials, elements, colors and treatments with the existing structure): Architectural façade change elements may be comprised of, but are not limited to, one or more of the following treatments: cornices, bases, fenestration, corbelled masonry, architectural accent walls, exaggerated parapets, horizontal banding, portico or awning faces, wainscoting, balconies, simulated balconies, arches, louvers, pilasters, faux glazing, and color banding. a. Finish materials/elements. i. Metal sided structures shall feature pitched roofs or other variations in roof height, as well as, appropriate molding, trim or hemming at all exposed edges and corners. Highly galvanized finishes are prohibited. All facades shall incorporate at least two elements and at least two colors. Glazing on the primary façade(s) shall be in addition to the two elements. ii. Other building types. The primary wall façade shall incorporate at least three materials, in addition to the glazing. Other wall facades shall incorporate at least two materials. External wall materials shall be comprised of masonry (e.g., brick, stone, concrete with paint or texture coat finish, concrete masonry units, etc.) or exterior stucco, with accents of metal or wood paneling, cementitious fiber board, or alternate products if approved by the city. b. The primary wall materials shall be nonreflective. Accent materials may be reflective upon city approval. c. Primary facades, except for multi-family structures, shall contain a minimum of 25 percent glazing. In the GBE district, if the primary facade faces the Ford Idaho Center, 25 percent glazing shall also be required for the facade facing Idaho Center Boulevard. d. Primary façade. A change of elements shall be visible over at least 50 percent of the exterior wall area of any primary façade. Color variation can be used in the 50 percent change calculation up to ten percent. e. Other façades. A change of elements shall be visible over 30 percent of any other façade (meaning no one material can exceed 70 percent of the exposed wall face). Color variation can be used in the 30 percent change calculation up to ten percent. 2. Exterior structure finish colors. a. Black, fluorescent, or bright colors shall only cover 25 percent of any wall unless approved otherwise by the city. 3. Visual displacements. a. Structure walls, or portions thereof, that exceed 50 feet in length shall provide jogs and offsets and have changes in roof height to break up the flat plane of such walls. There shall be an emphasis of material changes and/or jogs and offsets around the public entrance. b. Overhead doors for service or repair activities, or for loading and unloading, shall be located at the side of a building which lies away from any residential use or zone, unless some form of screening such as landscaping, a wall, landscape berm, or other barrier is used to separate the two. c. Loading docks shall not face the front of the property, nor the front of any adjacent principal building, unless sufficiently screened from view by landscaping, another structure or topography. 4. Roofing materials. Roofing materials shall be of a finish that emits a minimal amount of glare. When oriented/sloped toward a parking area, arterial or collector roadway, it shall be finished in a material that compliments the exterior structure finish materials. Thermoplastic Polyolefin (TPO), is not an acceptable material for the exposed area of the roof. 5. Mechanical units. Mechanical equipment and utilities shall be placed and installed in such a way as to be minimally visible from adjoining properties, and, shall be screened from public view with either proper landscaping or enclosures which are consistent with the architectural aesthetics and characteristics of the main building. a. Mechanical vents and similar features protruding through the roof shall be painted so as to match the color of the roof. Exposed metal flashing or trim shall be anodized or painted to blend with the exterior colors of the building. Roof mounted mechanical units shall be screened from public view from any street abutting the property by a screen wall enclosure consistent in appearance with the architectural treatment of the main building. b. Ground mounted equipment and utilities shall be placed and installed in such a way to have the least impact on adjoining properties and shall be screened from public view with either landscaping or a screen wall. Landscaping shall include a combination of evergreen and deciduous bushes and trees, with a minimum of five-foot depth continuous around utility. This five-foot landscaping buffer shall contain plantings, irrigation, landscaping fabric and ground cover. Mechanical units may be contained within a screen wall enclosure consistent in its construction with the architectural aesthetics and characteristics of the main building. 6. Building lighting standards. a. On buildings. All exterior structure lighting shall be shielded, screened, or shuttered with 90° cutoff luminaries and shall be directed so as to prevent direct illumination of adjoining properties. b. The height of a freestanding light fixture (e.g., in a parking lot area) shall not exceed 25 feet. Parking area lights shall use 90° cutoff luminaries (i.e., "downlighting"). c. Lighting to highlight or illuminate architecture and signs shall not have significant spillage of light upward or downward. d. Pedestrian circulation routes shall be illuminated. e. Floodlights shall not be allowed, except when necessary for security. 7. Certain property improvements. The following additional standards shall apply to projects requiring design review: a. Fencing/screening. Fencing of anything other than mechanical or maintenance related equipment or stored inventory or trash receptacles is prohibited. Trash receptacles shall be screened with durable materials as found on the related building's facade. Exception: shall be added to screen or secure outside storage of inventory, screen or secure storage facilities, as defined in section 10-1-16, and to screen areas of the property that are not landscaped or are left to gravel. Fencing shall be ornamental in design and constructed with at least two materials, or one material with two variations in texture, design or color that complement the primary wall façade. Fencing shall not be an extension of a wall façade that gives the appearance of a fortification or extensive plane. Rather, fencing should provide attractive visual interest, complement the character of the structures and provide necessary screening (if applicable). Some examples include, but are not limited to: stacked stone masonry with mortared cap; textured block wall and cap with color variation; wrought iron with finials; iron fence with a stone base; wrought iron with wood slats; cable railing with large dimension wood posts; modern metal fence with a patina; unique pattern or design; etc. Fencing constructed with materials such as chain link, chain link with slats, corrugated metal, typical residential wood or vinyl fencing and long expanses of solid single material fencing with no variation or visual interest are not permitted in areas that are visible from the right-of-way. i. Fencing exceptions: Typical residential wood or vinyl fencing may be used as privacy fencing for multi-family projects along the sides and rear of the development. Fencing proposed along the right-of-way shall meet the standards listed above. School yards may be fenced with chain link where appropriate, to provide for student safety. The chain link fence may be built up to a height of six feet to enclose the area not defined as front yard. Fencing proposed in the area defined as the front yard shall meet the standards listed above. b. Trash receptacles. Trash receptacles shall be located in service areas at side or rear yards and shall not be visible from streets abutting a property. Trash receptacles shall be screened from view with durable materials, such as CMU block or similar material. Such screening shall match the color and/or material of the primary structure. c. Landscaping. Landscaping is not required for review at the design review level unless it is used to screen trash enclosures and/or mechanical units and to mitigate long walls, multi-family (MF) structures with tall blank walls that encase a stairwell, or in locations in relation to gateways into the city. Multi-family developments shall meet the following open space requirements: i. Multi-family recreation space requirements. At least five percent of the total net acreage of all residential buildable area shall be retained as recreation space. In lieu of the five percent requirement, three percent of the total net residential buildable area may be retained as indoor recreation area in "corridor" multi-family developments that qualify (see subsection 10-34-10.A.2.c.vi). ii. All recreation space shall be both legally and physically available and accessible to all occupants of dwelling units in the development. (1) Recreation space shall include area that: (A) Is not covered by, parking lots, or accessory structures (except commonly held recreational structures). (B) Is not enclaved inside individual, privately held building lots. (C) Is not part of any proposed or existing street, common driveway, private driveway or parking pad, alley, or exclusive easement. (D) Is not proposed to be platted into lots arranged in such oddly dimensioned, unusable shapes, as to be considered realistically unusable, as determined by the director or his/her designee. (E) Is not in an unsuitable area or in an inaccessible easement. (F) Is not sloped such that it creates a dangerous or hazardous condition. iii. (1) All recreation space with active recreational elements shall be sloped per industry standards for those activities and shall provide accommodation for ADA access. iv. Recreation space calculation. (1) Drainage basins as recreation space. (A) Drainage basins or portions thereof that meet the "multi-use" facility standards identified in Nampa Engineering Drainage and Stormwater Policy and have a surface suitable for recreational use shall count towards the total percentage of recreation space. Suitable surfaces include turf, hardscape, and others as approved by the Nampa Engineering Division and planning department. Filter sand is not considered a suitable surface. Vegetation (plants, grasses, shrubs, trees) shall be selected appropriately to withstand the periodic or frequent inundation with water. Mulch if used shall be a nonfloatable material. (B) Multi-use facilities that provide other benefits beyond active recreation and that integrate into the character of the development and compliment the surrounding recreation space and corresponding amenities may also count towards the total percentage of recreation space. Inclusion of these areas are subject to the review and approval of the Nampa engineering division and planning department. Examples include, but are not limited to: • Permanent pools for active/passive recreation. • Constructed wetland/wildlife habitat areas. • Other landscape features designed to mimic natural spaces. (2) Natural areas as recreation space. Natural areas that have water features, forested areas, wetlands and other natural landform landscapes may be considered qualified open space. Access to at least 50 percent of the perimeter of the natural area must be provided via an ADA accessible pathway, otherwise these areas are not considered qualified open space. Connecting pathways through the natural area counts towards the perimeter calculation. (3) Landscape buffer credit towards recreation space. 50 percent of a landscape buffer that has a pathway meandering through it may be used as recreation space. (4) Community plazas credit towards recreation space. The area of a community plaza that is part of the multi-family development property, open to the elements; including covered walkways, gazebos, trellis-covered areas, landscaping planters, fountains, and sitting areas, may count towards recreation space. Any areas of a community plaza covered by buildings, accessory buildings, parking and loading facilities for these areas is not considered recreation space. v. Distribution of recreation space. Recreation space shall contain a centralized recreational area within the development and the remainder shall be distributed throughout the development. (1) The portion of a recreation space area that is established for a specific recreational use shall contain slopes that are appropriate for that use. In no case will open space areas be sloped such that it creates a dangerous or hazardous condition. (2) All recreation space areas shall be designed to provide reasonable accommodation for ADA access. vi. Recreation space may be provided indoors under the following circumstances: Multi-family residential development in the DV (downtown village) or a BC (community business) zoning district within 300 feet of the Caldwell Blvd., Garrity Blvd., 12th Ave S, 12th Ave. Rd., Idaho Center Blvd., Franklin Blvd., Northside Blvd. and Karcher Rd. Corridors with buildings exceeding 30 feet in height may provide up to 100 percent of their recreational space inside residential structures in indoor recreational facilities (gym, recreation room, pool, etc.) for use of the multi-family development residents. (See chapter 3-2—Residential development—footnote 10). d. Pedestrian pathways. Pedestrian paths shall be established to enhance a site's character and connections. Developments of one acre or more shall provide a pedestrian and bicycle circulation plan for the site. i. All on-site circulation systems shall incorporate a streetscape which includes sidewalks, pedestrian scale light standards and street trees. ii. Pedestrian amenities shall include detached sidewalks that provide connectivity of buildings and parking areas to public spaces and rights-of-way. Public spaces are required for projects over 25,000 square feet in gross floor space at a ratio of ten square feet of public space per 10,000 square feet of gross floor space. The public spaces must include landscaping and seating and must provide connectivity (either immediate or eventual by linkage as appropriate) to any on-property pedestrian routes. 9. Sign placeholding. The locations of future wall-mounted or free- standing signs shall be identified on site and elevation drawings provided to the city as part of a design review application. The materials and colors of any future free-standing sign, where known, shall be shared with the committee. Sign superstructures shall have their materials and colors harmonize with the building materials and colors to which they are associated. B. The following standards apply to all parcels within the IL and IH zones: The following standards shall not apply to industrial buildings within developments that have a recorded final plat where buildings have been constructed prior to March 21, 2023: 1. Structure exteriors and finish materials/elements. Wall facades of new buildings or new additions shall be reviewed as specified hereafter: Architectural façade change elements may be comprised of, but are not limited to, one or more of the following treatments: cornices, bases, fenestration, corbelled masonry, architectural accent walls, exaggerated parapets, horizontal banding, portico or awning faces, wainscoting, balconies, simulated balconies, arches, louvers, pilasters, faux glazing, and color banding. a. Finish materials/elements. i. Metal sided structures shall feature pitched roofs or other variations in roof height, as well as, appropriate molding, trim or hemming at all exposed edges and corners. Highly galvanized finishes are prohibited. All facades shall incorporate at least two elements and at least two colors. Glazing on the primary façade(s) shall be in addition to the two elements. ii. Other building types. All facades shall incorporate at least two elements and at least two colors. Glazing on the primary façade(s) shall be in addition to the two elements. External wall materials shall be comprised of masonry (e.g., brick, stone, concrete with paint or texture coat finish, concrete masonry units, etc.) or exterior stucco, with accents of metal or wood paneling, cementitious fiber board, or alternate products if approved by the city. b. The primary wall materials shall be nonreflective. Accent materials may be reflective upon city approval. c. If there is only one primary façade identified, it shall contain a minimum of ten percent glazing. Any request to be below ten percent shall be mitigated and reviewed by the design review committee. Any significant decrease in these percentages may be assigned to the committee as an exception request and mitigation of some kind will be required. d. If there are two primary façades identified, the first primary façade (containing the primary entrance) shall provide seven percent glazing and the second primary façade shall provide five percent glazing. These percentages are based on the exposed square footage of each respective, identified wall area. Any significant decrease in these percentages may be reviewed by the committee as an exception request and mitigation of some kind will be required. The glass in any approved overhead door, on the primary façade(s), may be used in the glazing calculation. e. Primary façade change of elements. Any one element on the primary façade(s) cannot exceed 70 percent of the exposed wall face. f. Other façades that are facing and within 300 feet of a major street. Any one element on the other façade(s) cannot exceed 70 percent of the exposed wall face. g. Other façades where subsections 10-34-10.B.1.e and 10-34-10.B.1.f do not apply, will not require a review of design standards. 2. Exterior structure finish colors. a. Black, fluorescent, or bright colors shall only cover 25 percent of any wall unless approved otherwise by the city. 3. Visual displacements. a. Structure walls, or portions thereof, that exceed 100 feet in length shall provide jogs and offsets and have changes in roof height to break up the flat plane of such walls. There shall be an emphasis of material changes and/or jogs and offsets around the public entrance. b. Overhead doors for service, repair and deliveries shall be located at the side of a building which lies away from any nonindustrial use or zone, any arterial or collector streets, and any public spaces, unless sufficiently screened from view by landscaping, another structure or topography. c. Loading docks shall not face the front of the property or any nonindustrial property that is immediately adjacent to the project unless sufficiently screened from view by landscaping, another structure or topography. 4. Mechanical units. Mechanical equipment and utilities shall be placed and installed in such a way as to be minimally visible from adjoining properties, and, shall be screened from public view with either proper landscaping or enclosures which are consistent with the architectural aesthetics and characteristics of the main building. a. Mechanical vents and similar features protruding through the roof shall be painted so as to match the color of the roof. Exposed metal flashing or trim shall be anodized or painted to blend with the exterior colors of the building. Roof mounted mechanical units shall be screened from public view from any street abutting the property by a screen wall enclosure consistent in appearance with the architectural treatment of the main building. b. Ground mounted equipment and utilities shall be placed and installed in such a way to have the least impact on adjoining properties and shall be screened from public view with either landscaping or a screen wall. Landscaping shall include a combination of evergreen and deciduous bushes and trees, with a minimum of five-foot depth continuous around utility. This five-foot landscaping buffer shall contain plantings, irrigation, landscaping fabric and ground cover. Mechanical units may be contained within a screen wall enclosure consistent in its construction with the architectural aesthetics and characteristics of the main building. 5. Lighting standards. a. All exterior structure and parking lot lighting shall be shielded, screened, or shuttered with 90° cutoff luminaries and shall be directed so as to prevent direct illumination of adjoining properties. b. Lighting to highlight or illuminate architecture and signs shall not have significant spillage of light upward or downward. 6. Certain property improvements. The following additional standards shall apply to projects requiring design review: a. Fencing/screening. Fencing/screening shall be used to screen mechanical units, maintenance related equipment, stored inventory, areas left to gravel and trash enclosures. Landscaping treatments can be used in lieu of fencing as approved by city staff. The use of chain link and chain link with slats along any street frontage shall be prohibited. Wing walls or wing fences shall be constructed out of other appropriate fencing materials or materials that match the proposed building finishes. Wing wall or wing fencing shall be ornamental in design and constructed with at least two materials, or one material with two variations in texture, design or color that complement the primary wall façade. Fencing should provide attractive visual interest, complement the character of the structures and provide necessary screening (if applicable). Some examples include, but are not limited to: stacked stone masonry with mortared cap; textured block wall and cap with color variation; wrought iron with finials; iron fence with a stone base; wrought iron with wood slats; cable railing with large dimension wood posts; modern metal fence with a patina; unique pattern or design; etc. Fencing constructed with materials such as chain link, chain link with slats, corrugated metal, or typical residential wood and long expanses of solid single material fencing with no variation or visual interest are not permitted in areas that face a roadway, customer parking, or main drive aisle, that are visible from the right-of-way, or can be viewed by an adjacent nonindustrial property. i. Fencing exceptions: School yards may be fenced with chain link where appropriate, to provide for student safety. The chain link fence may be built up to a height of six feet to enclose the area not defined as front yard. Fencing proposed in the area defined as the front yard shall meet the standards listed above. b. Trash receptacles. Trash receptacles shall be screened from view with durable materials, such as CMU block or similar material. Such screening shall match the color and/or material of the primary structure. c. Landscaping. Landscaping is not required for review at the design review level unless it is used to screen trash enclosures, mechanical units, maintenance equipment, and/or stored inventory and to mitigate long, exposed walls. 7. Sign placeholding. The locations of future wall-mounted or free-standing signs shall be identified on site and elevation drawings. Sign superstructures shall have their materials and colors harmonize with the building materials and colors to which they are associated. Any multi-tenant project shall submit a sign package for review and approval per NCC subsections 10-23-18.S and 10-23-20.F.

(Ord. No. 4617, § 1(Exh. A), 10-4-2021; Ord. No. 4671, § 1(Exh. A), 5-16-2022; Ord. No. 4728, § 1(Exh. A), 4-3-2023; Ord. No. 4776, § 1(Exh. A), 12-18-2023; Ord. No. 4777, § 1(Exh. A), 12-18-2023; Ord. No. 4809, § 1(Exh. A), 6-3-2024; Ord. No. 4907, § 9, 1-5-2026)

Ask a question about Nampa law

Corpus searches the Nampa sections it holds and shows the ones that match, with their citations. Free, no sign-in.