Sec. 37-197. - Supplementary requirements for buildings within the MFUniv District.
(a) Parking design is subject to the following requirements: (1) Vehicular access to parking must be taken from the alley for any lot abutting a public alley. The Planning and Development Director may waive this requirement upon a determination that the adjacent alley prevents safe and efficient access to the lot because it is a dead end, is less than 16.5 feet in width, contains immovable obstacles, or has a degraded surface condition; (2) Ground level parking may not be located in front of the primary or secondary façade of a building. Ground level parking must be separated from the exterior wall comprising the primary façade by interior floor area having a minimum depth of twenty (20) feet. For secondary façades, ground level parking must be screened by a wall at least four (4) feet in height extending along the entire breadth of the parking area. This wall may be interrupted by one driveway not to exceed twenty-three (23) feet in width, as well as one additional pedestrian access point; (3) Upper level parking must be screened along any primary or secondary façade by an exterior wall extending from floor to ceiling along the entire length of the wall. This wall may contain windows and ventilation grilles. (b) A minimum of twenty percent (20%) of the area of every floor frontage facing a public street must consist of transparent glass. (c) Each building shall have a primary entrance facing a public street allowing pedestrian access via a connection to a public sidewalk. The primary entrance shall be covered by a shelter that is at least two (2) feet six (6) inches in depth and five (5) feet in width. This shelter may be provided with a projection from the wall, an inset into the wall, or a combination of the two. (d) No material other than brick shall constitute more than seventy percent (70%) of any façade facing a public street, exclusive of the windowed portion of the façade. (e) Exterior walls seventy-five (75) feet in length or greater that face public streets are subject to the following articulation requirements: (1) A minimum of two (2) feet in variation in the vertical plane of said walls must occur at intervals of fifty (50) feet or less along the horizontal length of the wall. Intervals do not need to be equal in width. At least fifty percent (50%) of the vertical surface area of each horizontal interval must be recessed, projected, or offset to meet this requirement. (2) Architectural features that may satisfy this requirement include, but are not limited to: wall offsets, projections and/or recesses, columns, bay windows, and balconies. These features may encroach into required yards subject to the requirements of Section 37-221.
(C.B. No. 2016-211, § 1(Exh. A), 10-18-16; C.B. No. 2018-149, § 1(Exh. A), 9-18-18; C.B. No. 2019-130, § 1(Exh. A), 8-6-19)
Ask a question about Champaign law
Corpus searches the Champaign sections it holds and shows the ones that match, with their citations. Free, no sign-in.