Sec. 37-199. - Supplementary requirements for the design of multifamily buildings in the In-Town Zoning Districts.

The construction of new multifamily buildings containing three or more dwelling units in any In-Town Zoning District shall comply with the following design standards: (a) The primary façade of the building shall front on a public street. (b) Buildings that have dwelling units situated above ground-level dwelling units shall be designed to have one or more common-entrance(s) on the primary façade of the building whereby apartments are accessed from the interior of the building through common hallways. Buildings designed as rowhouses or townhouses that do not contain dwelling units above the ground-level dwelling units may have entrances to individual units. (c) Each building entrance shall contain a dedicated hard-surfaced pedestrian walkway at least four feet in width that connects directly to the street sidewalk in the right-of-way. (d) Building entrances shall be covered by a shelter that is at least five (5) feet in depth and eight (8) feet in width. This shelter may be provided with a projection from the wall, an inset into the wall, or a combination of the two. (e) A building, or any attachments to or ornamentation upon a building, may encroach into the side and rear yard setbacks by up to three feet, provided that the total length of such encroachments shall not exceed 50% of the total horizontal length of the building facade. (f) Buildings designed to have a flat roof shall include a cornice along the entire frontage of any street facing façade of the building. The cornice shall be placed no lower than the ceiling height of the top floor and be designed to protrude from the face of the building a minimum of four (4) inches. (g) Buildings designed to have a pitched roof shall include eaves on all sides of the building with a minimum eave depth of eighteen (18) inches. (h) Buildings over two (2) stories in height shall not have a roof pitch greater than 3/12. (i) Buildings over two (2) stories in height shall have an expression line delineating the first floor. (j) A minimum of thirty percent (30%) of the area of every floor on the primary facade must consist of transparent glass. (k) A minimum of twenty percent (20%) of the area of every floor on any secondary façade must consist of transparent glass. (l) The height to width size ratio of any window shall be a minimum 2:1. (m) A minimum of sixty-five percent (65%) of the windows on the primary façade shall be grouped with at least two (2) windows per grouping. The spacing between individual windows in a grouping shall be no less than four (4) inches and no greater than eight (8) inches when measured between window mullions. (n) Windows are required to have sills and lintels that extend past the casing of the window. (o) No more than thirty (30%) of any primary or secondary building façade may contain balconies as measured by horizontal length. (p) Exterior building materials shall consist of one or more of the following: a. True brick; b. Stone; c. Wood or wood composite; d. Fiber Cement Board. (q) When available, vehicular access must be taken from a public alley. (r) Vehicular parking must be provided either at grade or below grade. Parking shall not be provided in a structure above grade. (s) Vehicular parking may only be provided underneath a building at grade when it is the rear one-half of the building, or less, as measured by the depth of the building from the primary facade. Vehicular parking may be provided underneath the front one-half of the building only if the parking facility is fully below grade. (t) The amount of vehicular parking required shall be 0.25 parking spaces per bedroom. The amount of bicycle parking required shall be one bicycle parking space per four (4) bedrooms. (u) Outdoor trash and recycling collection areas shall not be visible from the street containing the primary façade. (v) Where available, trash and recycling shall be placed so it can be collected from a public alley. (w) Trash and recycling areas shall be screened with opaque fencing at least six (6) feet in height. (x) Air conditioner condensers shall be screened with either opaque fencing or landscaping at least four (4) feet in height.

(C.B. No. 2018-149, § 1(Exh. A), 9-18-18; C.B. No. 2019-130, § 1(Exh. A), 8-6-19; C.B. No. 2021-156, § 1(Exh. A), 11-22-21; C.B. No. 2022-050, § 1(Exh. 1), 4-5-22; C.B. No. 2022-091, § 1(Exh. A), 6-7-22)

Ask a question about Champaign law

Corpus searches the Champaign sections it holds and shows the ones that match, with their citations. Free, no sign-in.